Aquiles Rossoni

Aquiles Rossoni

Auto-generated profile, based on publicly available information

Aquiles Rossoni

Department of Electrical Engineering, Federal University of Rio Grande do Sul, UFRGS, Porto Alegre, Brazil

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Electric Power Systems Research
Verified
Journal Article
Closed access
Arturo BretasArturo Bretas
Arturo Bretas
NBN.G. Bretas
N.G. Bretas
SBS.H. Braunstein
S.H. Braunstein
ARA. Rossoni
A. Rossoni
RTR.D. Trevizan
R.D. Trevizan

1 September 2020 in Electric Power Systems Research
Verified
Journal Article
Closed access
Arturo BretasArturo Bretas
Arturo Bretas
ARAquiles Rossoni
Aquiles Rossoni
RTRodrigo D. Trevizan
Rodrigo D. Trevizan
NBNewton G. Bretas
Newton G. Bretas

1 June 2015
Verified
Conference Paper
Closed access
RTRodrigo Daniel Trevizan
Rodrigo Daniel Trevizan
ARAquiles Rossoni
Aquiles Rossoni
Arturo BretasArturo Bretas
Arturo Bretas
DGDaniel da Silva Gazzana
Daniel da Silva Gazzana
RMRodolfo de Podesta Martin
Rodolfo de Podesta Martin
LPLuis Fernando Do Nascimento Passos
Luis Fernando Do Nascimento Passos
This work proposes a new method to identify non-technical losses in typical Electrical Power Distribution Systems (EPDS). Aiming to improve the efficiency of on-site inspection for fraudulent clients, the consumers are classified in suspects and non-suspects using the Optimum-Path Forest (OPF) classifier. The authors propose an improvement to this method using results of a Distribution State Estimator (DSE) and geographic information. The method is tested in the IEEE 123 Bus Test Feeder considering a group of consumers for each load. The consumers are based on typical Brazilian residential consumers. The results indicate that the proposed method improves the performance of previously developed techniques and is suitable for both typical and smart EPDS. The best results are obtained when the DSE and OPF are associated using normalized data as the input for this hybrid approach, with expected success rate of up to 72.43% for on-site inspections in the EPDS test system.

1 July 2015
Verified
Conference Paper
Closed access
SBSergio Halpern Braunstein
Sergio Halpern Braunstein
NBNewton Geraldo Bretas
Newton Geraldo Bretas
ARAquiles Rossoni
Aquiles Rossoni
Arturo BretasArturo Bretas
Arturo Bretas
This paper presents a study of bad data analysis in distribution state estimation considering pseudo-measurements given by load models. The bad data analysis is performed using the residual analysis, based on chi-square and normalized residual tests, and the geometrical approach, based on the use of composed measurement error and composed normalized error. This is the first work that assesses the geometrical analysis for distribution systems. A numerical study is conducted considering a 69-bus distribution system with advanced metering infrastructure. The results show a potential improvement using the geometrical analysis.

1 October 2015
Verified
Conference Paper
Closed access
RTRodrigo D. Trevizan
Rodrigo D. Trevizan
Arturo BretasArturo Bretas
Arturo Bretas
ARAquiles Rossoni
Aquiles Rossoni
This paper presents a Discrete Cosine Transform (DCT) and Optimum-Path Forest (OPF) based approach for Nontechnical Losses (NTL) detection. NTL decrease the economic efficiency of distribution utilities, which harms the entire society since energy prices increase as a consequence. Pattern Recognition based approaches have been applied to identify these losses so that the problems related to NTL may be corrected through on-site inspections. One of the main characteristics of NTL is the decrease in the customer's measured monthly-consumed energy, caused by frauds or failure of the energy meter, which is called “consumption step”. This record of kWh consumption can be treated as a time-series and then benefit from the knowledge available in this area. In this paper DCT and OPF were used as a means of implementing automatic feature extraction. The pro-posed method was compared with an OPF based approach previously proposed by the authors. Test results show that feature extraction using DCT can provide a more compact and efficient way of representing data, improving the performance of previously developed methods by the authors.

14 November 2016
Verified
Conference Paper
Closed access
ARAquiles Rossoni
Aquiles Rossoni
SBSergio Halpern Braunstein
Sergio Halpern Braunstein
RTRodrigo Daniel Trevizan
Rodrigo Daniel Trevizan
Arturo BretasArturo Bretas
Arturo Bretas
NBNewton Geraldo Bretas
Newton Geraldo Bretas
This paper presents a method to estimate and identify technical and non-technical power losses in distribution systems based in a hybrid state estimation approach. The proposed method is divided in two steps. In the first step, non-technical power losses are detected, identified and corrected using a geometrical based state estimator technique. In the second step, a pattern recognition technique is applied on consumers aiming intelligent weight of load measurements. On this second step, power losses are estimated with the updated weight matrix. The proposed approach was numerically analyzed in a 69-bus distribution system considering an advanced metering infrastructure. The results show a potential improvement of the proposed method when compared with the state-of-the-art residual based state estimator approach.