Wooram Kim

Dr. Wooram Kim

KAIST (Korea Advanced Institute of Science and Technology)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WKWooram Kim
Wooram Kim
Haijin FuHaijin Fu
Haijin Fu
KLKeunwoo Lee
Keunwoo Lee
Seongheum HanSeongheum Han
Seongheum Han
YJYoon-Soo Jang
Yoon-Soo Jang
Seung-Woo KimSeung-Woo Kim
Seung-Woo Kim
We report an absolute interferometer configured with a 1 GHz microwave source photonically synthesized from a fiber mode-locked laser of a 100 MHz pulse repetition rate. Special attention is paid to the identification of the repeatable systematic error with its subsequent suppression by means of passive compensation as well as active correction. Experimental results show that passive compensation permits the measurement error to be less than 7.8 μm (1 σ) over a 2 m range, which further reduces to 3.5 μm (1 σ) by active correction as it is limited ultimately by the phase-resolving power of the phasemeter employed in this study. With precise absolute distance ranging capability, the proposed scheme of the photonic microwave interferometer is expected to replace conventional incremental-type interferometers in diverse long-distance measurement applications, particularly for large machine axis control, precision geodetic surveying and inter-satellite ranging in space.

18 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
QNQuoc Khanh Nguyen
Quoc Khanh Nguyen
SKSeungman Kim
Seungman Kim
SHSeong-Heum Han
Seong-Heum Han
SRSeung-Kook Ro
Seung-Kook Ro
Seung-Woo KimSeung-Woo Kim
Seung-Woo Kim
JOJeong Seok Oh
Jeong Seok Oh
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 µm, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 µm, while the maximum deviation estimated by the conventional self-calibration method was 711.9 µm. Validation of 3D coordinate measurements in a 1000 mm × 1000 mm × 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 µm. Conversely, the maximum difference was 98.8 µm using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.

3 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
WKWooram Kim
Wooram Kim
JYJaewon Yang
Jaewon Yang
JJJaeyoung Jang
Jaeyoung Jang
JOJeong Seok Oh
Jeong Seok Oh
Seongheum HanSeongheum Han
Seongheum Han
Seung-Woo KimSeung-Woo Kim
Seung-Woo Kim
We configured a long-distance ranging apparatus to test the principle of dual-comb time-of-flight measurement using ultrashort lasers. Emphasis was given to the evaluation of open-air performance quantitatively in terms of the measurement resolution and stability. The test results revealed that our dual-comb asynchronous optical pulse sampling permits micrometer-resolved ranging with a repeatability of 2.05 μm over a 648 m distance in dry weather conditions. Further atmospheric effects were evaluated in three different weather conditions with corresponding Allan deviations. Finally, the capability of simultaneous determination of multiple targets was verified with the potential of advanced industrial applications, such as manufacturing, surveying, metrology, and geodesy.