Even after the Heydemann correction, residual nonlinear errors, ranging from hundreds of picometers to several nanometers, are still found in heterodyne laser interferometers. This is a crucial factor impeding the realization of picometer level metrology, but its source and mechanism have barely been investigated. To study this problem, a novel nonlinear model based on optical mixing and coupling with ghost reflection is proposed and then verified by experiments. After intense investigation of this new model’s influence, results indicate that new additional high-order and negative-order nonlinear harmonics, arising from ghost reflection and its coupling with optical mixing, have only a negligible contribution to the overall nonlinear error. In real applications, any effect on the Lissajous trajectory might be invisible due to the small ghost reflectance. However, even a tiny ghost reflection can significantly worsen the effectiveness of the Heydemann correction, or even make this correction completely ineffective, i.e., compensation makes the error larger rather than smaller. Moreover, the residual nonlinear error after correction is dominated only by ghost reflectance.
This paper reports a hitherto undiscovered cyclic error whose origin is different from that of conventional errors in homodyne interferometers. To explain this error, a model based on ghost reflections and the interference principle is developed. In general, in homodyne interferometers, multi-order Doppler frequency shift ghost beams participate in the final interference and generate multi-order cyclic errors. This “new” cyclic error is compared with conventional errors by means of Lissajous curves. And we establish a setup to validate our proposed model. We use a corner cube retroreflector to replace the mirror and we find the error is significantly reduced. We believe that our findings can contribute to the further development of highly accurate homodyne interferometers.
The phase quadrature measurement method is capable of measuring nonlinearity in heterodyne laser interferometers with picometer accuracy whereas it cannot be applied in the new kind of heterodyne interferometers with bidirectional Doppler frequency shift especially in the condition of non-uniform motion of the target. To solve this problem, a novel measurement method of nonlinearity is proposed in this paper. By employing double-channel quadrature demodulation and substituting the external reference signal with internal ones, this method is free from the type of heterodyne laser interferometer and the motion state of the target. For phase demodulation, the phase differential algorithm is utilized to improve the computing efficiency. Experimental verification is carried out and the results indicate that the proposed measurement method achieves accuracy better than 2 pm.
The tri-comb-based multi-heterodyne detection technique has been proven to be a powerful tool for precision metrology, e.g., laser ranging and spectroscopy. However, in existing tri-comb generation methods, it is difficult to provide a large and variable difference in tri-comb repetition rates. In this paper; we propose a multidimensional multiplexing mode-locked laser based on a dual-ring integrative structure. Combining the dimensions of sub-ring multiplexing and wavelength multiplexing, two modes of tri-comb generation can be achieved with the dual-ring single cavity laser. The generated combs are identified based on the relative intensity of the pulse trains and optical spectrum, and the repetition rates of dual-combs from the same sub-ring are distinguished based on dispersion analysis. With repetition rates of approximately 47 MHz and 49.6 MHz, the minimum and maximum repetition rate difference of the generated tri-comb can be changed from 2.38 kHz and 2.59526 MHz to 2.74 kHz and 2.59720 MHz merely by switching the operation mode of the dual-ring integrated mode-locked laser. The obtained results indicate that our method can offer a powerful scheme for future multi-comb generation and its application in multi-heterodyne detection-based laser ranging and spectroscopy.
16 April 2019 in IEEE Transactions on Instrumentation and Measurement
Homodyne laser vibrometer plays an essential role in the precision vibration measurement, but its application is restricted when measuring subfringe vibration and targets with various reflectivities. In order to achieve the nanoscale vibration measurement and to adapt to various reflectivities, an enhanced homodyne laser vibrometer is presented in this paper. First, an active vibration mechanism (AVM) based on a flexure hinge stimulated by a piezoelectric transducer (PZT) is introduced into the reference arm, with which the parameters for nonlinear error correction can be predetermined, and thereby the measurement of vibration less than quarter wavelength is feasible. Second, an automatic gain module is employed to optimize the intensity of the interference signals, which significantly improves the adaptability to target reflectivity. The experimental results show that the laser vibrometer proposed is capable of measuring vibration with amplitude down to 2 nm and vibration with surface reflectivity down to 0.08%.
A simple and robust analog feedforward and digital feedback compound control system is presented to lock the frequency of a slave continuous wave (CW) laser to an optical frequency comb. The beat frequency between CW laser and the adjacent comb mode was fed to an acousto-optical frequency shifter (AOFS) to compensate the frequency dithering of the CW laser. A digital feedback loop was achieved to expand the operation bandwidth limitation of the AOFS by over an order of magnitude. The signal-to-noise ratio of the interference signal was optimized using a grating-based spectral filtering detection unit. The complete system achieved an ultrastable offset-locking of the slave CW laser to the frequency comb with a relative stability of ±3.62 × 10−14. The Allan deviations of the beat frequency were 8.01 × 10−16 and 2.19 × 10−16 for a gate time of 10 s and 1000 s, respectively. The findings of this study may further improve laser interferometry by providing a simple and robust method for ultrastable frequency control.