Guolu Yin

Dr. Guolu Yin

Key Laboratory of Optoelectronic Technology & Systems (Ministry of Education), Chongqing University, Chongqing 400044, China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JZJiangtao Zhou
Jiangtao Zhou
YWYiping Wang
Yiping Wang
CLChangrui Liao
Changrui Liao
BSBing Sun
Bing Sun
Jun HeJun He
Jun He
JZJing Zhao
Jing Zhao

26 January 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
BSBing Sun
Bing Sun
Yiping WangYiping Wang
Yiping Wang
Junle QuJunle Qu
Junle Qu
CLChangrui Liao
Changrui Liao
Guolu YinGuolu Yin
Guolu Yin
YLYingjie Liu
Yingjie Liu
We investigated a novel and ultracompact polymer-capped Fabry-Perot interferometer, which is based on a polymer capped on the endface of a single mode fiber (SMF). The proposed Fabry-Perot interferometer has advantages of easy fabrication, low cost, and high sensitivity. The variation of the Fabry-Perot cavity length can be easily controlled by using the motors of a normal arc fusion splicer. Moreover, the enhanced mechanical strength of the Fabry-Perot interferometer makes it suitable for high sensitivity pressure and temperature sensing in harsh environments. The proposed interferometer exhibits a wavelength shift of the interference fringes that corresponds to a temperature sensitivity of 249 pm/°C and a pressure sensitivity of 1130 pm/MPa, respectively, around the wavelength of 1560 nm.

1 January 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Open access
BJBiqiang Jiang
Biqiang Jiang
KZKaiming Zhou
Kaiming Zhou
CWChangle Wang
Changle Wang
QSQizhen Sun
Qizhen Sun
Guolu YinGuolu Yin
Guolu Yin
LZLin Zhang
Lin Zhang

11 April 2018 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
Yongfeng LiuYongfeng Liu
Yongfeng Liu
XTXiaosheng Tang
Xiaosheng Tang
Tao ZhuTao Zhu
Tao Zhu
MDMing Deng
Ming Deng
IIIroegbu Paul Ikechukwu
Iroegbu Paul Ikechukwu
FQFeng Qiu
Feng Qiu
Pollutions caused by heavy metals has become a wordwide concerned issue. Herein, CsPbBr 3 perovskite quantum dots are used as fluorescent probe for selective detection of copper ions in organic phase with a limit of detection (LOD) down to 0.1 nM.

16 January 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
JZJiangtao Zhou
Jiangtao Zhou
Changrui LiaoChangrui Liao
Changrui Liao
Yiping WangYiping Wang
Yiping Wang
Guolu YinGuolu Yin
Guolu Yin
XZXiaoyong Zhong
Xiaoyong Zhong
ZLZhengyong Li
Zhengyong Li
We demonstrated a novel fiber in-line Mach-Zehnder interferometer (MZI) with a large fringe visibility of up to 17 dB, which was fabricated by misaligned splicing a short section of thin core fiber between two sections of standard single-mode fiber. Such a MZI could be used to realize simultaneous measurement of tensile strain and temperature. Tensile strain was measured with an ultrahigh sensitivity of −0.023 dB/μɛ via the intensity modulation of interference fringes, and temperature was measured with a high sensitivity of 51 pm/°C via the wavelength modulation of interference fringe. That is, the MZI-based sensor overcomes the cross-sensitivity problem between tensile strain and temperature by means of different demodulation methods. Moreover, this proposed sensor exhibits the advantages of low-cost, extremely simple structure, compact size (only about 10 mm), and good repeatability.

5 January 2015 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SLShen Liu
Shen Liu
KYKaiming Yang
Kaiming Yang
Yiping WangYiping Wang
Yiping Wang
Junle QuJunle Qu
Junle Qu
CLChangrui Liao
Changrui Liao
JZJing Zhao
Jing Zhao
We demonstrated a unique rectangular air bubble by means of splicing two sections of standard single mode fibers together and tapering the splicing joint. Such an air bubble can be used to develop a promising high-sensitivity strain sensor based on Fabry-Perot interference. The sensitivity of the strain sensor with a cavity length of about 61 μm and a wall thickness of about 1 μm was measured to be up to 43.0 pm/με and is the highest strain sensitivity among the in-fiber FPI-based strain sensors with air cavities reported so far. Moreover, our strain sensor has a very low temperature sensitivity of about 2.0 pm/°C. Thus, the temperature-induced strain measurement error is less than 0.046 με/°C.