Research Group TEP 130, Architecture, Heritage and Sustainability: Acoustics, Lighting, Optics and Energy Department of Architectural Construction, Research, University Institute of Architecture and Construction Sciences IUACC, Universidad de Sevilla, 41012 Seville, Spain
Dr. Antonio Garcia-Martinez
Research Group TEP 130, Architecture, Heritage and Sustainability: Acoustics, Lighting, Optics and Energy Department of Architectural Construction, Research, University Institute of Architecture and Construction Sciences IUACC, Universidad de Sevilla, 41012 Seville, Spain
This study investigates the diurnal, seasonal, monthly and temporal variation of land surface temperature (LST) and surface urban heat island intensity (SUHII) over the Isfahan metropolitan area, Iran, during 2003–2019 using MODIS data. It also examines the driving factors of SUHII like cropland, built-up areas (BI), the urban–rural difference in enhanced vegetation index (ΔEVI), evapotranspiration (ΔET), and white sky albedo (ΔWSA). The results reveal the presence of urban cool islands during the daytime and urban heat islands at night. The maximum SUHII was observed at 22:30 p.m., while the minimum was at 10:30 a.m. The summer months (June to September) show higher SUHII compared to the winter months (February to May). The daytime SUHII demonstrates a robust positive correlation with cropland and ΔWSA, and a negative correlation with ΔET, ΔEVI, and BI. The nighttime SUHII displays a negative correlation with ΔET and ΔEVI.
During the last decades natural polymers have become more and more frequent to replace traditional inorganic stabilizers in building materials. The purpose of this research is to establish a comparison between the most conventional building material solutions for load-bearing walls and a type of biomaterial. This comparison will focus on load-bearing walls as used in a widespread type of twentieth century dwelling construction in Europe and still used in developing countries nowadays. To carry out this analysis, the structural and thermal insulation characteristics of different construction solutions are balanced. The tool used for this evaluation is the life cycle assessment throughout the whole lifespan of these buildings. This research aims to examine the environmental performance of each material assessed: fired clay brick masonry walls (BW), concrete block masonry walls (CW), and stabilized soil block masonry walls (SW) stabilized with natural fibers and alginates. These conventional and new materials are evaluated from the point of view of both operational and embodied energy.
1 September 2018 in Journal of Architectural Engineering
Currently, Uruguay is developing several measures to reduce the environmental impact of human activities and CO2 emissions. In 2015 more than 90% of electricity was produced by renewable sources. Despite this fact, the construction, transport, and building sectors are still responsible for more than 60% of CO2 emissions. Reducing building environmental impacts is becoming an increasing challenge. Lifecycle assessment (LCA) is recognized as a method that can help to reduce the environmental impact of the building sector. The LCA can be used as an early-stage decision-making tool to assess design choices that impact the environment. The present paper developed a method based on LCA that integrates building information modeling (BIM) to assess building envelope alternatives. The method is validated by the application in a single-family house, which is the most popular typology, in Uruguay, considering three envelope alternatives including frequent and nonfrequent materials. Results focused on comparing the embodied impacts, transport, and operational energy consumptions of each scenario. The results show that the developed method can help during the building design process, especially when defining dimension and thickness of materials.
The excessive use of energy in buildings due to increased populations and economic development leads to more greenhouse gas emissions, which affect climate change and global warming. Changes in prevailing outdoor weather conditions significantly affect the energy systems of buildings through increased cooling and decreased heating. In this paper, 30 years of data of dry and wet bulb temperatures (1990–2020) with a time interval of 3 h were considered in order to estimate the climatic outdoor design conditions in the cities of Dallas–Fort Worth, Houston, and San Antonio in the state of Texas. The results suggest that the dry bulb temperature (DBT) had significantly higher increases in Dallas–Fort Worth (2.37 °C) than the wet bulb temperature (WBT) in Houston (4.1 °C) during the study period. Furthermore, this study analyzed the effects of climate change on cooling degree hours (CDH) and heating degree hours (HDH) and the results suggest the most significant drop in HDH in Dallas–Fort Worth with a maximum CDH fluctuation as compared to other two cities. The effect of climate change on the performance of cooling systems is also investigated in this study via direct evaporative coolers (DECs) and direct-indirect evaporative coolers (IDEC), which do not perform well in the selected cities. In contrast, absorption system (Abs) and vapor compression (VC) systems show an increase in the number of additional loads. The second part of this study is related to the future projection using the ARIMA model, which suggests that DBT would rise significantly in Houston (from 37.18 °C to 37.56 °C) and Dallas–Fort Worth (39.1 °C to 39.57 °C) while diminishing in San Antonio (from 34.81 °C to 33.95 °C) from 2020 to 2030. In contrast, WBT will experience an upward trend in Houston (from 36.06 °C to 37.71 °C) and Dallas–Fort Worth (from 31.32 °C to 31.38 °C) and a downward trend in San Antonio (from 32.43 °C to 31.97 °C) during 2020–2030. Additionally, the future performance prediction of Abs and VC systems is also performed, which reveals that the amount of additional load required is significantly higher in 2030 compared to 2020 and is more prominent in Houston. Conversely, amount of additional load required for cooling systems in San Antonio shows a decreasing trend in 2030.