Mohammad Nikkhoo

Dr. Mohammad Nikkhoo

Science and Research Branch, Islamic Azad University, Tehran, Iran
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2019 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Mohammad NikkhooMohammad Nikkhoo
Mohammad Nikkhoo
CCChih-Hsiu Cheng
Chih-Hsiu Cheng
JWJaw-Lin Wang
Jaw-Lin Wang
ZKZahra Khoz
Zahra Khoz
MEMarwan El-Rich
Marwan El-Rich
KKKinda Khalaf
Kinda Khalaf

10 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
GAGhasem Akbari
Ghasem Akbari
Mohammad NikkhooMohammad Nikkhoo
Mohammad Nikkhoo
Lizhen WangLizhen Wang
Lizhen Wang
CCCarl P. C. Chen
Carl P. C. Chen
DHDer-Sheng Han
Der-Sheng Han
HCHsin-Yi Cheng
Hsin-Yi Cheng
Frailty is one of the most important geriatric syndromes, which can be associated with increased risk for incident disability and hospitalization. Developing a real-time classification model of elderly frailty level could be beneficial for designing a clinical predictive assessment tool. Hence, the objective of this study was to predict the elderly frailty level utilizing the machine learning approach on skeleton data acquired from a Kinect sensor. Seven hundred and eighty-seven community elderly were recruited in this study. The Kinect data were acquired from the elderly performing different functional assessment exercises including: (1) 30-s arm curl; (2) 30-s chair sit-to-stand; (3) 2-min step; and (4) gait analysis tests. The proposed methodology was successfully validated by gender classification with accuracies up to 84 percent. Regarding frailty level evaluation and prediction, the results indicated that support vector classifier (SVC) and multi-layer perceptron (MLP) are the most successful estimators in prediction of the Fried’s frailty level with median accuracies up to 97.5 percent. The high level of accuracy achieved with the proposed methodology indicates that ML modeling can identify the risk of frailty in elderly individuals based on evaluating the real-time skeletal movements using the Kinect sensor.

1 April 2020 in The Spine Journal
Verified
Journal Article
Closed access
WHWei-Li Hsu
Wei-Li Hsu
CCCarl Pc Chen
Carl Pc Chen
Mohammad NikkhooMohammad Nikkhoo
Mohammad Nikkhoo
CLCheng-Feng Lin
Cheng-Feng Lin
CCCongo Tak Shing Ching
Congo Tak Shing Ching
HCHsin-Yi Cheng
Hsin-Yi Cheng

1 March 2020 in Journal of Biomechanics
Verified
Journal Article
Closed access
Mohammad NikkhooMohammad Nikkhoo
Mohammad Nikkhoo
ZKZahra Khoz
Zahra Khoz
HCHsin-Yi Cheng
Hsin-Yi Cheng
CNChi-Chien Niu
Chi-Chien Niu
MEMarwan El-Rich
Marwan El-Rich
KKKinda Khalaf
Kinda Khalaf

4 January 2021 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
SBSami Beirami
Sami Beirami
Mohammad NikkhooMohammad Nikkhoo
Mohammad Nikkhoo
KHKamran Hassani
Kamran Hassani
AKAlireza Karimi
Alireza Karimi
The locking compression plate (LCP) system has several advantages in fracture fixation combining angular stability with the use of locking screws with traditional fixation techniques. However, the system is complex and requiring careful attention to biomechanical principles and good surgical technique. Due to the set of complicate stresses and strains in the LCP system after implantation, the material, which is being used here, is deemed important. However, so far the materials have been limited to the stainless steel (SS) or titanium (Ti). This study was therefore aimed at investigate the biomechanical performance of the internal tibial locked plates at different material properties, including SS, Ti, carbon/polyether ether ketone (PEEK) composite, in treating medial tibial fracture using patient-specific finite element (FE) model of the human tibia. The carbon/PEEK composite materials were used at three different fiber plies configurations. Simulated loading was applied at 60:40 ratios on the medial:lateral aspect. The model was fixed distally in all degrees of freedom. The results revealed the highest stress (307.10 MPa) and the lowest strain (0.14%) at Ti LCP system. The carbon/PEEK LCP system at configuration I and III showed low stress (∼60 MPa) and high strain (0.70%), which are suitable points for designing of an internal LCP system. On the other hand, the highest value of stress in callus region was 4.78 MPa (Carbon PEEK/Configuration I) and the strain variations of callus region were between 1.46% and 3.82% among all materials. These results implied the advantage of carbon/PEEK composite materials in LCP system as they can tolerate higher strains at lower stresses.