Kamil Staněk

Dr. Kamil Staněk

University Centre for Energy Efficient Buildings, Czech Technical University in Prague, Prague, Praha, Hlavní Město, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Composites Part B: Engineering
Verified
Journal Article
Closed access
Anuj KumarAnuj Kumar
Anuj Kumar
KSKamil Staněk
Kamil Staněk
PRPavla Ryparová
Pavla Ryparová
Petr HajekPetr Hajek
Petr Hajek
JTJan Tywoniak
Jan Tywoniak

1 January 2016 in Procedia Engineering
Verified
Journal Article
Open access
JRJan Richter
Jan Richter
KSKamil Staněk
Kamil Staněk
Values of water vapour resistance factor (μ-value) are one of crucial parameters for numerical modelling in building physics. To obtain a reliable μ-value is not so straight forward and requires good measurement equipment and skills. This paper at first briefly introduces a cup test which is commonly used method for evaluation of μ-values. Consequently a new test cups made out of fiberglass were tested regarding their vapour tightness as well as different sealant materials. Additionally the μ-values of three types of gypsum plasterboards were evaluated and data compared with values from other material databases. A good agreement of measured data was achieved

28 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
JRJan Richter
Jan Richter
KSKamil Staněk
Kamil Staněk
JTJan Tywoniak
Jan Tywoniak
PKPavel Kopecký
Pavel Kopecký
During the last few decades, unheated attic spaces (so-called “cold attics”) have been one of the most moisture-problematic spaces in the building practices of Europe and North America. Problems with such spaces are usually associated with condensation, frost formation, and mould growth on the lower surfaces of the roof deck. To solve these problems, a number of qualitative studies were performed. Although these studies revealed many important pieces of information, some of them are seemingly not in accordance with one another. Therefore, there has not yet been presented cold attic design which is suitable (especially moisture-safe) for the whole target region. The aim of this paper is to determine whether such a design can be determined or state the reasons why it is not possible. Based on a review of published studies, 38 cold attic designs were selected for detailed analysis. Their comparative parameters were established, quantified, and compared. The moisture-safeness of each design was evaluated using an original approach, and the designs were sorted into groups based on their similarities. Despite many uncertainties, it was found that the criteria for moisture-safe cold attic design in the target region can likely be stated.

1 October 2017 in Energy Procedia
Verified
Journal Article
Open access
PKPavel Kopecký
Pavel Kopecký
KSKamil Staněk
Kamil Staněk
MBMichal Bureš
Michal Bureš
JRJan Richter
Jan Richter
JTJan Tywoniak
Jan Tywoniak

1 November 2021 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
JRJan Richter
Jan Richter
KSKamil Staněk
Kamil Staněk
Although the water vapour permeability of wood has been determined many times, there can be found a wide spread of values even related to only one wood specie and its single anatomical direction. This spread can possibly be attributed to the measurement method itself, since the cup method often shows high inter-laboratory error. However, even if the measurement and evaluation processes are well performed and under control, there were found several factors that can still highly affect the resulting value – up to ca. 70 %. These factors are neither mentioned in standards, nor were found in other sources. This paper theoretically describes those factors and their possible impact to the final value of water vapour permeability. Paper also presents one particular measurement scheme and obtained data from four cup tests performed on spruce wood in transverse direction.

16 June 2019 in Energies
Verified
Journal Article
Open access
PDF file
JTJan Tywoniak
Jan Tywoniak
VCVítězslav Calta
Vítězslav Calta
KSKamil Staněk
Kamil Staněk
JNJiří Novák
Jiří Novák
LMLenka Maierová
Lenka Maierová
This paper deals with a small but important component in a building envelope, namely roof windows in pitched roofs. Building physics methods were used to support the search for new solutions which correspond to the maximum extent for requirements for passive house level design. The first part of the paper summarizes the key phenomena of heat transfer, mainly based on a comparison of vertical windows in walls. The results of repeated two-dimensional heat transfer calculations in the form of parametric studies are presented in order to express the most important factors influencing thermal transmittance and minimum surface temperatures. Several configuration variants suitable for technical design are discussed. It was found that a combination of wood and hardened plastics in the window frame and sash is the preferred solution. The resulting thermal transmittance can be up to twice as low as usual (from 0.7 down to 0.5 W/(m2·K), with further development ongoing. Surface temperature requirements to avoid the risk of condensation can be safely fulfilled. Concurrently, it is shown that the relative influence of thermal coupling between the window and roof construction increases with the improvement of window quality. Specific attention was given to the effect of the slanting of the side lining, which was analyzed by simulation and measurement in a daylight laboratory. The increase in thermal coupling due to slanting was found to be negligible. Motivations for specific building physics research are mentioned, such as the need to study the surface heat transfer in the case of inclined windows placed in a deep lining.