Pekik Argo Dahono

Prof. Pekik Argo Dahono


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2021 in Energies
Verified
Journal Article
Open access
PDF file
TATri Ardriani
Tri Ardriani
PDPekik Argo Dahono
Pekik Argo Dahono
ARARWINDRA RIZQIAWAN
ARWINDRA RIZQIAWAN
EGErna Garnia
Erna Garnia
PSPungky Dwi Sastya
Pungky Dwi Sastya
MRMuhammad Ridwan
Muhammad Ridwan
DC microgrid has been gaining popularity as solution as a more efficient and simpler power system especially for remote areas, where the main grid has yet to be built. This paper proposes a DC microgrid system based on renewable energy sources that employs decentralized control and without communication between one grid point and another. It can be deployed as an individual isolated unit or to form an expandable DC microgrid through DC bus for better reliability and efficiency. The key element of the proposed system is the power conditioner system (PCS) that works as an interface between energy sources, storage system, and load. PCS consists of modular power electronics devices and a power management unit, which controls power delivery to the AC load and the grid as well as the storage system charging and discharging sequence. Prototypes with 3 kWp solar PV and 13.8 kWh energy storage were developed and adopt a pole-mounted structure for ease of transportation and installation that are important in remote areas. This paper presents measurement results under several conditions of the developed prototypes. The evaluation shows promising results and a solid basis for electrification in remote areas.

28 April 2006
Verified
Conference Paper
Closed access
PDPekik Argo Dahono
Pekik Argo Dahono
DWD.P. Wulandari
D.P. Wulandari
A new concept of virtual inductor is introduced in this paper. Virtual inductor is defined as an additional control algorithm that changes the system behavior into the one that has an additional inductor connected on it. The virtual nature of the inductor makes the inductance can be designed without weight and volume restrictions. How to use the virtual inductor to improve the performance of converter current controller is discussed in this paper. Several simulated and experimental results are included to show the validity of the proposed concept

1 November 2007
Verified
Conference Paper
Closed access
DEDeni
Deni
ESE. G. Supriatna
E. G. Supriatna
PDPekik Argo Dahono
Pekik Argo Dahono
An output current ripple analysis of five phase PWM inverters under sinusoidal and nonsinusoidal operations is presented in this paper. A general expression of output current ripple of five-phase PWM inverters under nonsinusoidal operation is first derived. Under sinusoidal operation it is found that the optimum reference signal that results in minimum output current ripple is a sinusoidal reference signal. Under nonsinusoidal operation, however, it is found that fifth harmonic injection can be used to reduce the output current ripple. Moreover, fifth harmonic injection is useful to increase the maximum modulation index of five-phase PWM inverter. Simulation and experimental results are included to show the validity of the derived expressions.

1 January 2011 in ITB Journal of Engineering Science
Verified
Journal Article
Open access
PDPekik Argo Dahono
Pekik Argo Dahono
ETEen Taryana
Een Taryana
A new voltage control method for single-phase full-bridge PWM inverters that having an output LC filter is proposed in this paper. The proposed voltage controller has a capability to realize a zero steady-state output voltage error with fast response. The zero steady-state output voltage error is achieved by using a controller that is derived by using the virtual LC resonant circuit. Fast response is obtained by using a virtual resistance that is connected in parallel with the filter capacitor. The validity of the proposed method is verified by experimental results

1 April 2007
Verified
Conference Paper
Closed access
PDPekik Argo Dahono
Pekik Argo Dahono
Under unbalanced operations, the rectifier produces significant subharmonic ripples that are difficult to filter out by using a real passive filter because the frequency is very low. In this paper, a new approach to reduce the low frequency ripples of a polyphase rectifier is proposed. In the proposed approach, the low frequency ripples of a polyphase rectifier output are minimized by using a virtual LC filter. Because this filter is virtual, the subharmonic ripples can be reduced significantly without using a large and expensive passive filter. Moreover, it can be designed in such way so it only responds to the disturbance signals and does not respond to the reference ones. So, the low-frequency ripples can be reduced without influencing the system response to reference. Experimental and simulated results are included to verify the proposed concept.

1 June 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
SWSulistyo Wijanarko
Sulistyo Wijanarko
GHGifari Iswandi Hasyim
Gifari Iswandi Hasyim
JFJihad Furqani
Jihad Furqani
ARARWINDRA RIZQIAWAN
ARWINDRA RIZQIAWAN
PDPekik Argo Dahono
Pekik Argo Dahono
AMAnwar Muqorobin
Anwar Muqorobin
One way to increase electric vehicle (EV) battery utilization is to connect it to a dc microgrid. The EV battery can assume the role of an energy storage from the grid point of view. A bidirectional DC-DC converter will be needed to transfer power between them back and forth. This paper proposes the converter design considering its functional objective, including interleaved phase number determination. Efficiency performance evaluation is presented by power loss analysis with the parasitic-parameters consideration of the components. Finding optimum switching frequency based on power loss analysis is performed independently between input and output sides of the converter. Finally, experiments using a scaled-down prototype are shown to verify the analytical analysis of the converter. The experimental results properly validate the power loss analytic analysis carried out in this paper with a maximum error of 2.04% at 1131-watt, 60 V battery voltage, and 140 V grid voltage. Maximum efficiency 96.97% is obtained at 301-watt, 130 V battery voltage, and 151 V grid voltage. Overall, the converter has a simple structure, capable to be operated in various levels of input and output voltages with a minimum battery side current ripple.