Anwar Muqorobin

Dr. Anwar Muqorobin

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
ARAgus Risdiyanto
Agus Risdiyanto
AKAnt. Ardath Kristi
Ant. Ardath Kristi
AJAgus Junaedi
Agus Junaedi
BSBambang Susanto
Bambang Susanto
NRNoviadi A. Rachman
Noviadi A. Rachman
AFAhmad Fudholi
Ahmad Fudholi
In solar power systems, irradiance value data are among the most important parameters. Such data can be used in installing photovoltaic (PV) modules, such as determining the exact location, tilt angle, and required area, for optimal power efficiency. In this study, the comprehensive simulation and implementation of a solar radiation meter with a PV cell and temperature sensor are presented. The irradiance measurement value is based on the power reading generated by the small capacity of the PV cell at a specific load converted into a digital value in the microcontroller using the implicit Newton polynomial interpolation (NPI) equation as a low-cost alternative method. The effect of temperature is included in the conversion to obtain precise measurement results. Firstly, the structure and characteristics of the PV cell are discussed. Secondly, the parameters, measuring method, and conversion of the measurement reading data using the NPI equation are presented to assess the results. Finally, the simulation of the solar radiation meter using the PSIM and implementation of the hardware are conducted to validate the concepts and compare their results. The proposed hardware has an average error of 2.72% in the implementation of the measurement test.

1 February 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
PIPudji Irasari
Pudji Irasari
PWPuji Widiyanto
Puji Widiyanto
AMAnwar Muqorobin
Anwar Muqorobin
MHMuhammad Fathul Hikmawan
Muhammad Fathul Hikmawan
This paper analyzes the feasibility of converting brushed direct current (BDC) to brushless direct current (BLDC) motor by substituting the wound rotor with a permanent magnet. The aim is to overcome the low quality of rewinding of wound rotors. The conversion was performed by redesigning the motor, referring to the old stator dimensions and motor specifications. Some suitable speed control systems were also examined. Technical analysis was executed by simulating motor characteristics, covering torque-speed curve, cogging, and ripple torques. Afterward, an economic analysis was done to determine the cost of making one rotor unit and the speed control and then compare it with the price of a new BDC motor with equivalent power. The results show that the motor produces 3.6 kW, 18.86 V, 176.71 A, and 28.53 Nm at 2,460 rpm with 2 phases configuration. The maximum cogging torque is 2.9 Nm. The cost of making one rotor unit plus speed control is higher than that of a new BDC motor. These results show that it is technically feasible to convert BDC into a BLDC motor but not economically or vice versa.

1 June 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
SWSulistyo Wijanarko
Sulistyo Wijanarko
GHGifari Iswandi Hasyim
Gifari Iswandi Hasyim
JFJihad Furqani
Jihad Furqani
ARARWINDRA RIZQIAWAN
ARWINDRA RIZQIAWAN
PDPekik Argo Dahono
Pekik Argo Dahono
AMAnwar Muqorobin
Anwar Muqorobin
One way to increase electric vehicle (EV) battery utilization is to connect it to a dc microgrid. The EV battery can assume the role of an energy storage from the grid point of view. A bidirectional DC-DC converter will be needed to transfer power between them back and forth. This paper proposes the converter design considering its functional objective, including interleaved phase number determination. Efficiency performance evaluation is presented by power loss analysis with the parasitic-parameters consideration of the components. Finding optimum switching frequency based on power loss analysis is performed independently between input and output sides of the converter. Finally, experiments using a scaled-down prototype are shown to verify the analytical analysis of the converter. The experimental results properly validate the power loss analytic analysis carried out in this paper with a maximum error of 2.04% at 1131-watt, 60 V battery voltage, and 140 V grid voltage. Maximum efficiency 96.97% is obtained at 301-watt, 130 V battery voltage, and 151 V grid voltage. Overall, the converter has a simple structure, capable to be operated in various levels of input and output voltages with a minimum battery side current ripple.

1 December 2022 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
PIPudji Irasari
Pudji Irasari
AMAnwar Muqorobin
Anwar Muqorobin
PWPuji Widiyanto
Puji Widiyanto
TNTajuddin Nur
Tajuddin Nur
IDI Nengah Diasta
I Nengah Diasta
PSPriyono Soetikno
Priyono Soetikno
This paper analyzes the performance of a pico hydropower plant consisting of an axial hydro turbine integrated with a permanent magnet generator (PMG) and connected to a power converter. The proposed system is aimed to obtain a wide system operation range to gain more power captured while maintaining time-harmonic distortion in voltage (THDv) that meets the standard. The PMG specification is 1 kW, 1 phase, 235 V, 50 Hz, 83 rpm. The design and simulation of PMG were carried out by analytical and numerical calculations using FEMM 4.2. The power converter was simulated using PSIM and functions to reduce the THDv and pass the generator voltage between 50–500 V. The results show the THDv of the generating system at the upper and lower limits of the passed voltage having a THDv below 5%. Meanwhile, the PMG performance characteristics at various currents and rotations produce efficiency of 87.20% at nominal current. From these results, it can be concluded that the pico hydropower plant works well as desired.

Verified
Journal Article
Open access
PDF file
RRRina Ristiana
Rina Ristiana
JWJony winaryo Wibowo
Jony winaryo Wibowo
TSTaufik Ibnu Ibnu Salim
Taufik Ibnu Ibnu Salim
Aam MuharamAam Muharam
Aam Muharam
AMAmin
Amin
SWSulistyo Wijanarko
Sulistyo Wijanarko
Reliable steering regulation under varying road curvature and actuator constraints remains a central challenge in autonomous electric vehicles (AEVs). Many exiting approaches rely on reactive error correction or treat preview information solely as a reference adjustment, limiting anticipation and physical consistency. This study proposes a prediction–preview steering control (PSC) framework in which future curvature information within state propagation and constraint handling enables forward-looking steering decisions while respecting dynamic and actuator limits. The method is evaluated using a lateral-heading vehicle model with real-road geometric variation. Experimental results indicate significant improvement in tracking performance, reducing lateral RMSE from 0.1747 m to 0.0074 m with a maximum deviation of 0.0889 m and limiting heading RMSE to 0.0867° (maximum 1.2046°). Steering angle commands remain bounded within ±8.7°, while steering angle rate is maintained within 40–60°/s, ensuring smooth and dynamically admissible operation. The proposed strategy offers a computationally efficient solution for embedded AEV steering systems and demonstrates improved robustness under practical curvature transitions.

6 March 2026 in Modelling
Verified
Journal Article
Open access
PDF file
SWSulistyo Wijanarko
Sulistyo Wijanarko
RRRina Ristiana
Rina Ristiana
AMAnwar Muqorobin
Anwar Muqorobin
PID (proportional integral derivative) control has been widely used in industry due to its simplicity in implementation and satisfactory performance. However, the controller tuning is very troublesome when used in complex and nonlinear systems. The full bridge boost converter (FBBC) is a nonlinear system, so the PID control application in this converter should be further explored. This paper introduces a control approach that integrates PID control with a Linear Quadratic Regulator (LQR) for FBBC. To enable linear control design, the FBBC is linearized around its steady state operating points. The control architecture is structured into four cases: Case 1: PI-LQR Output Feedback, Case 2: PI-LQR State Feedback, Case 3: PID-LQR Output Feedback, and Case 4: PID-LQR State Feedback. The analysis aims to identify the most reliable system performance under input voltage change and load variation. The simulation results indicate that under the input voltage and load changes, cases 2 and 4 produce faster settling times, each with a settling time of 0.025 s and 0.015 s, respectively. However, both controllers produce negligible steady state error (less than 1%). Overall, Case 4 (PID-LQR State Feedback) consistently delivers the best performance, characterized by faster settling time, negligible steady state error, optimal control signal, and significantly reduced oscillation in both the inductor current and output voltage.