Alena Stepanova

Dr. Alena Stepanova

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Nikita A. KuznetsovNikita A. Kuznetsov
Nikita A. Kuznetsov
IMIvan Murashov
Ivan Murashov
VCVera Chernonosova
Vera Chernonosova
BCBoris P. Chelobanov
Boris P. Chelobanov
ASAlena Stepanova
Alena Stepanova
PLPavel P. Laktionov
Pavel P. Laktionov
A stenting procedure aimed at blood flow restoration in stenosed arteries significantly improves the efficiency of vascular surgery. However, the current challenge is to prevent neointimal growth, which reduces the vessel lumen, in the stented segments in the long run. We tested in vivo drug-eluting coating applied by electrospinning to metal vascular stents to inhibit the overgrowth of neointimal cells via both the drug release and mechanical support of the vascular wall. The blend of polycaprolactone with human serum albumin and paclitaxel was used for stent coating by electrospinning. The drug-eluting stents (DESs) were placed using a balloon catheter to the rabbit common iliac artery for 1, 3, and 6 months. The blood flow rate was ultrasonically determined in vivo. After explantation, the stented arterial segment was visually and histologically examined. Any undesirable biological responses (rejection or hemodynamically significant stenosis) were unobservable in the experimental groups. DESs were less traumatic and induced weaker neointimal growth; over six months, the blood flow increased by 37% versus bare-metal stents, where it increased by at least double the rate. Thus, electrospun-coated DESs demonstrate considerable advantages over the bare-metal variants.

2 November 2018 in Materials
Verified
Journal Article
Open access
PDF file
Nikita A. KuznetsovNikita A. Kuznetsov
Nikita A. Kuznetsov
ASAlena Stepanova
Alena Stepanova
RKRen Kvon
Ren Kvon
TDTimothy Douglas
Timothy Douglas
Nikita A. KuznetsovNikita A. Kuznetsov
Nikita A. Kuznetsov
PLPavel P. Laktionov
Pavel P. Laktionov
Paclitaxel is a natural, highly lipophilic anti proliferative drug widely used in medicine. We have studied the release of tritium-labeled paclitaxel (3H-PTX) from matrices destined for the coating of vascular stents and produced by the electrospinning method from the solutions of polycaprolactone (PCL) with paclitaxel (PTX) in hexafluoisopropanol (HFIP) and/or solutions of PCL with PTX and human serum albumin (HSA) in HFIP or HIFP-dimethyl sulphoxide (DMSO) blend. The release of PTX has been shown to depend on the composition of electrospinning solution, as well as the surrounding medium, particularly the concentration of free PTX and PTX-binding biomolecules present in human serum. It was shown that 3D matrices can completely release PTX without weight loss. Two-phase PTX release from optimized 3D matrices was obtained: ~27% of PTX was released in the first day, another 8% were released over the next 26 days. Wherein ~2.8%, ~2.3%, and ~0.25% of PTX was released on day 3, 9, and 27, respectively. Considering PTX toxicity, the rate of its diffusion through the arterial wall, and the data obtained the minimum cytostatic dose of the drug in the arterial wall will be maintained for at least three months.

6 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
ASAlena Stepanova
Alena Stepanova
PLPetr P. Laktionov
Petr P. Laktionov
ACAnna V. Cherepanova
Anna V. Cherepanova
VCVera Chernonosova
Vera Chernonosova
GSGeorgiy Yu. Shevelev
Georgiy Yu. Shevelev
PLPavel P. Laktionov
Pavel P. Laktionov
Endothelization of the luminal surface of vascular grafts is required for their long-term functioning. Here, we have cultivated human endothelial cells (HUVEC) on different 3D matrices to assess cell proliferation, gene expression and select the best substrate for endothelization. 3D matrices were produced by electrospinning from solutions of poly(D,L-lactide-co-glycolide) (PLGA), polycaprolactone (PCL), and blends of PCL with gelatin (Gl) in hexafluoroisopropanol. Structure and surface properties of 3D matrices were characterized by SEM, AFM, and sessile drop analysis. Cell adhesion, viability, and proliferation were studied by SEM, Alamar Blue staining, and 5-ethynyl-2’-deoxyuridine (EdU) assay. Gene expression profiling was done on an Illumina HiSeq 2500 platform. Obtained data indicated that 3D matrices produced from PCL with Gl and treated with glutaraldehyde provide the most suitable support for HUVEC adhesion and proliferation. Transcriptome sequencing has demonstrated a minimal difference of gene expression profile in HUVEC cultivated on the surface of these matrices as compared to tissue culture plastic, thus confirming these matrices as the best support for endothelization.

1 April 2017 in Biochemistry (Moscow), Supplement Series B: Biomedical Chemistry
Verified
Journal Article
Closed access
PDF file
VCVera Chernonosova
Vera Chernonosova
RKRen Kvon
Ren Kvon
EKElena Kiseleva
Elena Kiseleva
ASAlena Stepanova
Alena Stepanova
PLPetr P. Laktionov
Petr P. Laktionov
Matrices fabricated by electrospinning from polycaprolactone solutions with human albumin or gelatin to 1,1,1,3,3,3-hexafluoroisopropanol have been investigated. Microstructure of matriх surface was analyzed using scanning electron microscopy. Protein distribution in the surface layer was studied by modification with N-(2-hydroxyethyl)phenazine and X-ray photoelectron spectroscopy. The protein concentration in the surface layer of matrices was up to 12 times higher than in the initial solution, and the lower the protein concentration in the solution, the higher the relative protein content is on the surface of matrices. During incubation of matrices in aqueous solutions protein concentration in the surface layer decreased by less than 10% during the first 30–60 min and remained at this level for a long time (seven days). Treatment with proteinase K resulted in about one-third decrease in protein concentration in the surface layer. Thus, both methods used in this study are applicable for analysis of the surface layer of materials fabricated by electrospinning from mixtures of synthetic and natural polymers; however, X-ray photoelectron spectroscopy appears to be a more informative and convenient method.

26 December 2025 in Journal of Bioactive and Compatible Polymers
Verified
Journal Article
Closed access
ASAlena Stepanova
Alena Stepanova
MKMaria Kharkova
Maria Kharkova
OOOlesia Osipova
Olesia Osipova
BCBoris Chelobanov
Boris Chelobanov
YCYuriy Chesalov
Yuriy Chesalov
PLPavel P. Laktionov
Pavel P. Laktionov
Three-dimensional scaffolds produced by electrospinning from blends of Tecothane™ TT-1074A (Tect) with varying concentrations of gelatin (Gl) in hexafluoroisopropanol were investigated for their physicochemical properties, stability at different pH levels, and bio- and hemocompatibility. To enhance hemocompatibility, bivalirudin (Bv) was incorporated into the surface layer of the scaffold fibers. All scaffolds exhibited good strength (up to 22 MPa) with a high yield point (about 400%). Storage for 1 month at different pH levels leads to moderate decrease of stiffness with bell-shape variation of the elongation at break. IR spectra did not reveal discernible hydrolysis of pH-sensitive bonds. These changes also did not correlate with fiber diameters and may be attributed to inter-fiber contacts and rearrangements in the fiber inner structure. Scaffolds containing 10% Gl and 1.5% Bv demonstrated good biocompatibility in terms of human umbilical vein endothelial cell (HUVEC) adhesion and proliferation, as well as minimal platelet adhesion, aggregation induction, and hemolysis. In conclusion, these findings indicate the suitability of Tect-based scaffolds for vascular graft production.