In the modern power system, Flexible Alternating Current Transmission System (FACTS) devices are widely used. An increased share of the distributed generation (DG) and the development of microgrids change the power flows in the existing distribution networks as well as a conventional power flow direction from the transmission to the distribution network level which may affect the overall stability aspects. The paper shows the FACTS devices’ implementation influence on the performance of the distribution network with integrated renewable energy sources (RES) observing the aspects of the oscillatory stability and the low-voltage motor starting. The FACTS devices, in particular the static var compensators (SVC), have been allocated according to a novel algorithm proposed in the paper. The algorithm uses an iterative process to determine an optimal location for implementation and rating power of SVC considering active power losses minimization, improvement of the voltage profile and maximizing return of investment (ROI) of FACTS devices. Novel constraints—transformer station construction constraint, SVC industrial nominal power value constraint and the constraint of distribution system operator (DSO) economic willingness to investment in the distribution network development are considered in the proposed algorithm. The analysis has been performed on 20 kV rural distribution network model in DIgSILENT PowerFactory software.
Microgrids (MG) take a significant part of the modern power system. The presence of distributed generation (DG) with low inertia contribution, low voltage feeders, unbalanced loads, specific X/R ratio and the low short-circuit power values makes the observation of the MG stability aspects different from the conventional bulk power system stability. This paper presents a review on the voltage and the frequency stability control methods applicable on the MGs. A brief overview of classification of MGs and MG operating modes is given. Some methods of voltage and frequency control are proposed and hierarchical frequency control is presented.
One of the main characteristics of power systems is keeping voltages within given limits, done by implementing fast automatic voltage regulators (AVR), which can raise generator voltage (i.e., excitation voltage) in a short time to ceiling voltage limits while simultaneously affecting the damping component of the synchronous generator electromagnetic torque. The efficient way to increase damping in the power system is to implement a power system stabilizer (PSS) in the excitation circuit of the synchronous generator. This paper proposes an enhanced algorithm for PSS tuning in the multimachine system. The algorithm is based on the analysis of system participation factors and the pole placement method while respecting the time domain behavior of the system after being subdued with a small disturbance. The observed time-domain outputs, namely active power, speed, and rotor angle of the synchronous generator, have been classified and validated with proposed weight functions based on the minimal square deviation between the initial values in a steady-state and all sampled values during the transitional process. The system weight function proposed in this algorithm comprises s-domain and time-domain indices and represents a novel approach for PSS tuning. The proposed algorithm performance is validated on IEEE 14-bus system with a detailed presentation of the results in a graphical and table form.
Driven by the need for sustainable and efficient energy systems, the optimal management of distributed generation, including photovoltaic systems and battery energy storage systems within prosumer households, is of crucial importance. This requires a comprehensive cost–benefit analysis to assess their viability. In this study, an optimization model formulated as a mixed-integer linear programming problem is proposed to evaluate the integration of battery storage systems for 10 prosumers on the radial feeder in Croatia and to quantify the benefits both from the prosumers’ perspective and that of the reduction in grid losses. The results show significant annual cost reductions for prosumers, totaling EUR 1798.78 for the observed feeder, with some achieving a net profit. Grid losses are significantly reduced by 1172.52 kWh, resulting in an annual saving of EUR 216.25 for the distribution system operator. However, under the current Croatian market conditions, the integration of battery storage systems is not profitable over the entire lifetime due to the high initial investment costs of EUR 720/kWh. The break-even analysis reveals that investment cost needs to decrease by 52.78%, or an inflation rate of 4.87% is required, to reach prosumer profitability. This highlights the current financial barriers to the widespread adoption of battery storage systems and emphasizes the need for significant cost reductions or targeted incentives.
The increasing spread of photovoltaic systems for private households (PVs) and electric vehicles (EVs) in order to reduce carbon emissions significantly impacts operation conditions in existing distribution networks. Variable and unpredictable PVs can stress distribution network operation, mainly manifested in voltage violations during the day. On the other hand, variable loads such as EV chargers which have battery storage in their configuration have the ability of storying a surplus energy and, if it is necessary, support a distribution network with energy, commonly known as vehicle-to-grid concept (V2G), to help voltage stability network enhancement. This paper proposes an optimal power flow (OPF)-based model for EV charging to minimize power exchange between the superior-10 kV grid and the observed distribution feeder. The optimization procedure is realized using the co-simulation approach that connects power flow analysis software and optimization method. Three different scenarios are observed and analysed. The first scenario is referred to as a base case without optimization. The second and third scenarios include optimal EV charging and discharging patterns under different constraints. To test the optimization model, a 90-bus unbalanced distribution feeder modelled based on real-life examples is used. The obtained results suggest that this optimization model does not only significantly reduce the power exchange between an external network and the distribution feeder but also improves voltage stability and demand curve in the distribution feeder.
This paper aims to present carefully selected scientific papers that have pushed the boundaries in the application of advanced computational intelligence–based methods in power engineering, mainly in optimal power system management. Contemporary development of the Smart Grid and detailed framework for power grid digitalization enabled the real and efficient application of advanced optimization algorithms presented in this paper. Papers that are not directly related to Smart Grid management are also considered, since they solve the partial challenges of planning and development with metaheuristic procedures, and according to the authors, they are highly applicable and represent a fundamental starting point for wider application. This paper covers papers and research whose results are reproducible and can be realized in production-grade software. The emphasis of the paper is on the considerate and impartial way of providing a concise overview of the methods for solving technical challenges within the accepted Smart Grid architecture. The paper is the result of many years of research and commitment to this field and represents the foundation for present research and development.