Hrvoje Glavaš

Prof. Dr. Hrvoje Glavaš

Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Osijek, Osječko-Baranjska Županija, Croatia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2023 in Processes
Verified
Journal Article
Open access
PDF file
Ivan GrgićIvan Grgić
Ivan Grgić
Mirko KarakašićMirko Karakašić
Mirko Karakašić
Hrvoje GlavašHrvoje Glavaš
Hrvoje Glavaš
Pejo KonjatićPejo Konjatić
Pejo Konjatić
Fused deposition modelling (FDM) 3D printers have the highest annual growth of 21.15% in the field of 3D printing. FDM desktop 3D printers account for 23.69% of FDM printers. The major drawback of FDM desktop printers is product accuracy, which is particularly pronounced when dimensionally inaccurate and multi-part printed products need to be fit together into a functional assembly. The research presented in this paper aims to determine the accuracy limits of FDM 3D printers when producing elements for assembly using a 3D printer in a tolerance-fit system. A novel method of computer-aided design (CAD) based on ISO 286 and the systematic calibration procedure of 3D printers were presented to achieve the dimensional accuracy of 3D printed parts. For this purpose, a set of nominal dimensions within the clearance fit was selected, and various CAD models were created according to the ISO 286 system of limits and fits. The CAD Slicer software–3D printer interaction was systematically examined for the best hardware and software features. It was found that the Horizontal Expansion parameter should be 0.0 mm and the Hole Horizontal Expansion parameter should be 0.13 mm. The Linear Advance factor was found to be 25. The measurement results showed that the desired tolerance ranges, system, and type of clearance fit could be achieved with a desktop 3D printer. The roundness tolerance for all clearance fits and shaft tolerance ranges in the hole base system was determined to join the parts into a clearance fit.

28 January 2019 in Buildings
Verified
Journal Article
Open access
PDF file
Hrvoje GlavašHrvoje Glavaš
Hrvoje Glavaš
Marijana Hadzima-NyarkoMarijana Hadzima-Nyarko
Marijana Hadzima-Nyarko
IBIvana Haničar Buljan
Ivana Haničar Buljan
TBTomislav Barić
Tomislav Barić
The structure of Tvrđa and its buildings date back to the Middle Ages. Tvrđa represents the Old Town of the city of Osijek and the best-preserved and largest ensemble of Baroque buildings in Croatia. After the withdrawal of the Ottomans in 1687, during the 18th century, the Austro-Hungarian administration systematically formed a new fortification system, regulated streets and squares and built a large number of military objects. Tvrđa took its present form in the 19th century and has kept it since then. Investigating the historical development of individual buildings, in addition to archival sources and existing architectural documentation, the obvious source of information are the buildings themselves. The aim of this paper is to explore the possibilities of using infrared thermography to find structural elements and hidden openings in historic buildings in Osijek’s Tvrđa. This paper describes the exploration of the 18th century openings on the facades of the former Kostić houses. The facades were bricked into the walls in the 19th century because houses were reused and their purposes changed from commercial to residential. Infrared thermography is often a starting, nondestructive testing method (NDT) for building analyses. This paper presents thermographic analyses of two buildings. The analyses were carried out in December 2017 and January 2018. Using a steady-state thermographic analysis of a building envelope as the first step, the audit was continued with step heating (SH) of an interest point where changes in a thermal pattern were expected due to additional bricking. Heat flux was generated by the usage of a heat gun for paint removal.

21 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
FRFilip Relić
Filip Relić
Predrag MarićPredrag Marić
Predrag Marić
Hrvoje GlavašHrvoje Glavaš
Hrvoje Glavaš
Ivica PetrovićIvica Petrović
Ivica Petrović
In the modern power system, Flexible Alternating Current Transmission System (FACTS) devices are widely used. An increased share of the distributed generation (DG) and the development of microgrids change the power flows in the existing distribution networks as well as a conventional power flow direction from the transmission to the distribution network level which may affect the overall stability aspects. The paper shows the FACTS devices’ implementation influence on the performance of the distribution network with integrated renewable energy sources (RES) observing the aspects of the oscillatory stability and the low-voltage motor starting. The FACTS devices, in particular the static var compensators (SVC), have been allocated according to a novel algorithm proposed in the paper. The algorithm uses an iterative process to determine an optimal location for implementation and rating power of SVC considering active power losses minimization, improvement of the voltage profile and maximizing return of investment (ROI) of FACTS devices. Novel constraints—transformer station construction constraint, SVC industrial nominal power value constraint and the constraint of distribution system operator (DSO) economic willingness to investment in the distribution network development are considered in the proposed algorithm. The analysis has been performed on 20 kV rural distribution network model in DIgSILENT PowerFactory software.

26 March 2021 in Fermentation
Verified
Journal Article
Open access
PDF file
Emmanuel Karlo NyarkoEmmanuel Karlo Nyarko
Emmanuel Karlo Nyarko
Hrvoje GlavašHrvoje Glavaš
Hrvoje Glavaš
Kristina HabschiedKristina Habschied
Kristina Habschied
Krešimir MastanjevićKrešimir Mastanjević
Krešimir Mastanjević
Foam stability and retention is an important indicator of beer quality and freshness. A full, white head of foam with nicely distributed small bubbles of CO2 is appealing to the consumers and the crown of the production process. However, raw materials, production process, packaging, transportation, and storage have a big impact on foam stability, which marks foam stability monitoring during all these stages, from production to consumer, as very important. Beer foam stability is expressed as a change of foam height over a certain period. This research aimed to monitor the foam stability of lager beers using image analysis methods on two different types of recordings: RGB and depth videos. Sixteen different commercially available lager beers were subjected to analysis. The automated image analysis method based only on the analysis of RGB video images proved to be inapplicable in real conditions due to problems such as reflection of light through glass, autofocus, and beer lacing/clinging, which make it impossible to accurately detect the actual height of the foam. A solution to this problem, representing a unique contribution, was found by introducing the use of a 3D camera in estimating foam stability. According to the results, automated analysis of depth images obtained from a 3D camera proved to be a suitable, objective, repeatable, reliable, and sufficiently sensitive method for measuring foam stability of lager beers. The applied model proved to be suitable for predicting changes in foam retention of lager beers.

1 October 2017
Verified
Conference Paper
Closed access
Hrvoje GlavašHrvoje Glavaš
Hrvoje Glavaš
Marko VukobratovićMarko Vukobratović
Marko Vukobratović
MPMario Primorac
Mario Primorac
DMDaniel Mustran
Daniel Mustran
Paper provides an overview of passive thermographic analysis of photovoltaic panels. Operation state of real photovoltaic system, power plant ETFOS 1, is described through detailed thermographic documentation. The importance of education needed for correct measurement and interpretation of thermodynamic state of photovoltaic (PV) modules has been emphasized. Influences that can change apparent temperature as reflection, transmission and emissivity of analyzed object are described. All parameters that influence on formation of thermographic records are analyzed. Problems in determining the actual temperature of PV module are illustrated with a scientific background. Through the analysis of 16 thermographs and their corresponding visual images, the state of the photovoltaic modules was presented. Three unexpected thermal patterns were observed and compared with the relevant literature.

12 July 2023 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Časlav LivadaČaslav Livada
Časlav Livada
Hrvoje GlavašHrvoje Glavaš
Hrvoje Glavaš
ABAlfonzo Baumgartner Baumgartner
Alfonzo Baumgartner Baumgartner
Dina JukićDina Jukić
Dina Jukić
Thermography is probably the most used method of measuring surface temperature by analyzing radiation in the infrared part of the spectrum which accuracy depends on factors such as emissivity and reflected radiation. Contrary to popular belief that thermographic images represent temperature maps, they are actually thermal radiation converted into an image, and if not properly calibrated, they show incorrect temperatures. The objective of this study is to analyze commonly used image processing techniques and their impact on radiometric data in thermography. In particular, the extent to which a thermograph can be considered as an image and how image processing affects radiometric data. Three analyzes are presented in the paper. The first one examines how image processing techniques, such as contrast and brightness, affect physical reality and its representation in thermographic imaging. The second analysis examines the effects of JPEG compression on radiometric data and how degradation of the data varies with the compression parameters. The third analysis aims to determine the optimal resolution increase required to minimize the effects of compression on the radiometric data. The output from an IR camera in CSV format was used for these analyses, and compared to images from the manufacturer’s software. The IR camera providing data in JPEG format was used, and the data included thermographic images, visible images, and a matrix of thermal radiation data. The study was verified with a reference blackbody radiation set at 60 °C. The results highlight the dangers of interpreting thermographic images as temperature maps without considering the underlying radiometric data which can be affected by image processing and compression. The paper concludes with the importance of accurate and precise thermographic analysis for reliable temperature measurement.