Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter–tissue contact impact lesion formation during PFA. A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter–tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.
Background: Insulin resistance (IR) in patients with type 2 diabetes mellitus (T2DM) represents a predictor of coronary artery disease (CAD). However, how IR is able to impact the severity of coronary atherosclerosis in non-diabetic patients is unknown. Objectives. We investigated the relation between the IR and the extent and severity of coronary atherosclerosis in non-diabetic patients referred to coronary angiography (CA) Methods: Consecutive patients undergoing to CA for acute coronary syndromes or stable angina were analyzed. The IR was assessed by mean of the homeostasis model assessment of insulin resistance (HOMA-IR) whereas the SYNTAX score (SS) was used as index of the severity of coronary atherosclerosis Results: Overall, 126 patients were included, with a median SS of 12 (IQR 5.25–20.5). Patients were divided in four groups according to the distribution in quartiles of SS (SS1-2-3-4). A significant correlation between HOMA-IR and SS was observed, especially in women. A progressive increase of HOMA-IR was observed in parallel with the increasing severity (from SS1 to SS4) and extension (1-2-3-vessel disease) of coronary atherosclerosis. Multivariable analysis showed that the HOMA-IR was the strongest independent predictor of severe (SS4) and extensive (three-vessel disease) coronary atherosclerosis. Conclusion: Insulin resistance goes hand in hand with the extension and severity of coronary atherosclerosis in non-diabetic patients. The HOMA index is an independent predictor of three-vessel disease at CA. The HOMA index could be useful for risk stratification of CAD even in absence of T2DM.
1 January 2002 in Journal of Neurological Surgery Part B: Skull Base
The registration accuracy of skin- and bone-implanted fiducials using a frameless stereotactic system were analyzed prospectively.Twenty-eight patients underwent resection of intra-axial neoplasmas after both skin- and bone-implantable fiducial markers were placed. Both sets of fiducials were independently co-registered to a magnetic resonance imaging data set acquired preoperatively using the ISG Viewing Wandtrade mark. Root mean square errors were recorded as an objective measure of registration accuracy of the two types of fiducials.Root mean square errors of bone-implanted fiducials registration were lower than those of skin fiducials; however, this difference was not statistically significant (p = 0.206).The registration accuracy of skin- and bone-implanted fiducials appears to be similar. Still, bone-implanted fiducials may be advantageous compared to skin fiducials when re-registration of the patient-image space is desired intraoperatively such as during major drift in the patient's position or after surgical repositioning.
Background: More and more heart failure (HF) patients aged ≥ 75 years undergo cardiac resynchronization therapy (CRT) device implantation, however the data regarding the outcomes and their predictors are scant. We investigated the mid- to long-term outcomes and their predictors in CRT patients aged ≥ 75 years. Methods: Patients in the Cardiac Resynchronization Therapy Modular (CRT MORE) Registry were divided into three age-groups: 80 years, chronic obstructive pulmonary disease (COPD) and chronic kidney disease (CKD). Over long-term follow-up (1020 days (IQR 680-1362)) mortality was higher in patients ≥ 75 years than in the other two groups. Hospitalization and composite event rates were similar in patients ≥ 75 years and those aged 65–74 (9 vs. 11.8%; p = 0.26, and 26.7 vs. 20.5%; p = 0.06). Conclusion: Positive clinical response and hospitalization rates do not differ between CRT recipients ≥ 75 years and those aged 65–74. However, age > 80 years, COPD and CKD are predictors of worse outcomes.
Aims: Intracardiac echocardiography-based electroanatomical mapping (EAM) improves procedural efficiency and safety in atrial fibrillation (AF) ablation and remains the standard of care. The CARTOSOUND FAM (AI FAM) module uses a deep-learning algorithm that automates left atrial reconstruction without manual contouring. This study aims to evaluate the 1-year outcomes of AI FAM compared to standard-of-care EAM in AF ablation. Methods and results: This study included 298 patients undergoing radiofrequency AF ablation between January 2021 and December 2023. Patients treated before January 2023 underwent standard-of-care EAM, while those in 2023 utilized AI FAM-based reconstruction. Baseline demographics, comorbidities, AF type, and medication use were recorded. Procedural characteristics, acute success, complications, and AF recurrence at 1-year follow-up were analysed. Of the 298 patients, 115 underwent mapping with AI FAM and 183 with EAM. Baseline characteristics were comparable. AI FAM reduced mean total procedure time (122.5 ± 23.5 vs. 129.0 ± 30.4 min, P = 0.040) and left atrial (LA) dwell time (78.3 ± 21.45 vs. 87.5 ± 28.2 min, P = 0.001). Acute procedural success was 98.3% in AI FAM vs. 98.9% in EAM with fewer complications observed in the AI FAM group (1 vs. 4). At 1 year, freedom from AF recurrence was comparable (80.0% AI FAM vs. 81.4% EAM at 1 year, LogRank P = 0.610). Conclusion: AI FAM was associated with incremental but significant procedural advantages over conventional contouring via reduced total procedure time and LA dwell time, without compromising acute and long-term safety and rhythm control efficacy. AI FAM integration with pulsed field ablation will mark another step towards making AF ablation more streamlined and accessible.
Pregnancy entails notable physiological alterations and hormonal fluctuations that affect the well-being of both the fetus and the mother. Cardiovascular events and arrhythmias are a major concern during pregnancy, especially in women with comorbidities or a history of arrhythmias. This paper provides an overview of the prevalence, therapies, and prognoses of different types of arrhythmias during pregnancy. The administration of antiarrhythmic drugs (AADs) during pregnancy demands careful consideration because of their possible effect on the mother and fetus. AADs can cross the placenta or be present in breast milk, potentially leading to adverse effects such as teratogenicity, growth restriction, or premature birth. The safety profiles of different classes of AADs are discussed. Individualized treatment approaches and close monitoring of pregnant women prescribed AADs are essential to ensure optimal maternal and fetal outcomes.