Viera Viera Zatkalíková

Dr. Viera Viera Zatkalíková

UNIVERSITY OF ŽILINA Faculty of Mechanical Engineering
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
SPStefan Podhorsky
Stefan Podhorsky
MŠMilan Štrbák
Milan Štrbák
TLTatiana Liptáková
Tatiana Liptáková
LMLenka Markovičová
Lenka Markovičová
Lenka KucharikovaLenka Kucharikova
Lenka Kucharikova
Plasma electrolytic polishing (PEP) is an environment-friendly alternative to the conventional electrochemical polishing (EP), giving optimal surface properties and improved corrosion resistance with minimum energy and time consumption, which leads to both economic and environmental benefits. This paper is focused on the corrosion behavior of PEP treated AISI 316L stainless steel widely used as a biomaterial. Corrosion resistance of plasma electrolytic polished surfaces without/with chemical pretreatment (acid cleaning) is evaluated and compared with original non-treated (as received) surfaces by three independent test methods: electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP), and exposure immersion test. All corrosion tests are carried out in the 0.9 wt.% NaCl solution at a temperature of 37 ± 0.5 °C to simulate the internal environment of a human body. The quality of tested surfaces is also characterized by optical microscopy and by the surface roughness parameters. The results obtained indicated high corrosion resistance of PEP treated surfaces also without chemical pretreatment, which increases the ecological benefits of PEP technology.

30 November 2022 in Materials
Verified
Journal Article
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
MUMilan Uhríčik
Milan Uhríčik
LMLenka Markovičová
Lenka Markovičová
Lenka KucharikovaLenka Kucharikova
Lenka Kucharikova
Corrosion resistance of sensitized austenitic stainless steel (SS) in chloride environments is currently the subject of numerous studies. Most of them are focused on neutral chloride solutions at room temperature and the experiments are carried out on ground stainless steels surfaces. This paper deals with the corrosion behavior of sensitized AISI 304 stainless steel in acid 1 M chloride solution (pH = 1.1) at the temperatures of 20 ± 3 °C and 50 °C. The specimens after sensitization are tested as covered by high-temperature surface oxides (“heat tinted”), and also after their chemical removal to assess the impact of the surface state on corrosion resistance. Potentiodynamic polarization (PP) and exposure immersion test are used as the independent corrosion tests. Microstructure before/after exposure immersion test is evaluated by optical microscopy (OM) and SEM. The results obtained showed that sensitization significantly conditions corrosion regardless of the removal of high-temperature oxides, and the elevated temperature mainly acts as its accelerating factor.

21 August 2023 in Materials
Verified
Journal Article
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
MUMilan Uhríčik
Milan Uhríčik
LMLenka Markovičová
Lenka Markovičová
LPLucia Pastierovičová
Lucia Pastierovičová
Lenka KucharikovaLenka Kucharikova
Lenka Kucharikova
Due to the combination of high corrosion resistance and suitable mechanical properties, AISI 316L stainless steel is extensively used as the biomaterial for surgical implants. However, heat exposure in inappropriate temperatures can cause its sensitization accompanied by chromium depletion along the grain boundaries. This study deals with an assessment of the susceptibility of sensitized AISI 316L biomaterial to pitting under conditions simulating the internal environment of the human body (Hank’s balanced salt solution, 37 ± 0.5 °C). The resistance to pitting corrosion is tested by the potentiodynamic polarization and by the 50-day exposure immersion test. Corrosion damage after the exposure immersion test is evaluated in the specimens’ cross-sections by optical microscope and SEM. Despite passive behavior in potentiodynamic polarization and shallow, slight corrosion damage observed after exposure, the sensitized AISI 316L biomaterial could represent a risk, especially in long-term implantation even after the chemical removal of high-temperature oxides.

1 October 2014 in Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
LMLenka Markovičová
Lenka Markovičová
JBJuraj Belan
Juraj Belan
TLTatiana Liptáková
Tatiana Liptáková
AISI 316Ti is Cr-Ni-Mo austenitic stainless steel stabilized by Ti, recommended for construction of various industrial and medicine devices. In spite of its high Pitting Equivalent Resistance Number (PREN=23.688) it underlies local corrosion n...

4 January 2019 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
LML Markovičová
L Markovičová
AISI 304 is Cr-Ni austenitic stainless steel currently used for numerous applications that require high corrosion resistance. Due to the passive surface film this steel is resistant against a uniform corrosion, but halides present in environment can evoke local pitting. Electropolishing is recommended to obtain the high quality passive film and to increase the pitting corrosion resistance. This paper is focused on the assessment of the effect of elevated temperature (50 °C) on the resistance of AISI 304 electropolished surface to pitting corrosion in acidified 1 M chloride solution. Evaluation is based on the results of electrochemical cyclic potentiodynamic polarization tests (determination and comparison of pitting potentials Ep) and on the microscopic observation of specimen surfaces attacked by pitting during performed testing procedure.

12 November 2013 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
FSFrantisek Schlosser
Frantisek Schlosser
JMJan Mikolaj
Jan Mikolaj
VZViera Viera Zatkalíková
Viera Viera Zatkalíková
JSJuraj Sramek
Juraj Sramek
DDDominika Durekova
Dominika Durekova
LRLuboš Remek
Luboš Remek
Deformation properties and fatigue performance are important characteristics of asphalt bound materials which are used for construction of pavement layers. Viscoelastic asphalt mixtures are better characterized via dynamic tests. This type of tests allows us to collate materials with regard to axle vibrations which lie usually in the range of 6 Hz–25 Hz for standard conditions. Asphalt modified for heat sensitivity in the range from −20°C to +60°C has significant impact on the overall characteristics of the mixture. Deformation properties are used as inputs for empirical mixture design, and fatigue performance of asphalt mixtures reflects the parameters of functional tests. Master curves convey properties of asphalt mixtures for various conditions and allow us to evaluate them without the need of time expensive testing.