With an increasing number of naturally ventilated dairy barns (NVDBs), the emission of ammonia and greenhouse gases into the surrounding environment is expected to increase as well. It is very challenging to accurately determine the amount of gases released from a NVDB on-farm. Moreover, control options for the micro-climate to increase animal welfare are limited in an NVDB at present. Both issues are due to the complexity of the NVDB micro-environment, which is subject to temporal (such as wind direction and temperature) and spatial (such as openings and animals acting as airflow obstacles) fluctuations. The air exchange rate (AER) is one of the most valuable evaluation entities, since it is directly related to the gas emission rate and animal welfare. In this context, our study determined the general and local AERs of NVDBs of different shapes under diverse airflow conditions. Previous works identified main influencing parameters for the general AER and mathematically linked them together to predict the AER of the barn as a whole. The present research study is a continuation and extension of previous studies about the determination of AER. It provides new insights into the influence of convection flow regimes. In addition, it goes further in precision by determining the local AERs, depending on the position of the considered volume inside the barn. After running several computational fluid dynamics (CFD) simulations, we used the statistical tool of general linear modeling in order to identify quantitative relationships between the AER and the following five influencing parameters, the length/width ratio of the barn, the side opening configuration, the airflow temperature, magnitude and incoming direction. The work succeeded in taking the temperature into account as a further influencing parameter in the model and, thus, for the first time, in analysing the effect of the different types of flow convection in this context. The resulting equations predict the barn AER with an equals 0.98 and the local AER with a mean equals around 0.87. The results go a step further in the precise determination of the AER of NVDB and, therefore, are of fundamental importance for a better and deeper understanding of the interaction between the driving forces of AER in NVDB.
The tracer gas method is one of the common ways to evaluate the air exchange rate in a naturally ventilated barn. One crucial condition for the accuracy of the method is that both considered gases (pollutant and tracer) are perfectly mixed at the points where the measurements are done. In the present study, by means of computational fluids dynamics (CFD), the mixing ratio NH/CO is evaluated inside a barn in order to assess under which flow conditions the common height recommendation guidelines for sampling points (sampling line and sampling net) of the tracer gas method are most valuable. Our CFD model considered a barn with a rectangular layout and four animal-occupied zones modeled as a porous medium representing pressure drop and heat entry from lying and standing cows. We studied three inflow angles and six combinations of air inlet wind speed and temperatures gradients covering the three types of convection, i.e., natural, mixed, and forced. Our results showed that few cases corresponded to a nearly perfect gas mixing ratio at the currently common recommendation of at least a 3 m measurement height, while the best height in fact lied between 1.5 m and 2.5 m for most cases.
Ammonia and greenhouse gases have a negative impact on the environment. The most important agricultural sources of ammonia are dairy cattle housing systems, which are mainly naturally ventilated. Estimating emissions for naturally ventilated barns (NVB) is challenging due to the large number of influencing factors. Most notably, the direct coupling of the inside flow regime with ambient and turbulent weather conditions causes difficulties in measuring ventilation rates, gas concentrations and emissions; thus, different methods are available. In this study, we compared the outputs of total volume flow obtained by two indirect methods (CO mass balance) to the direct method. The latter we assume in this study as the reference method since it is a fundamental approach that estimates airflow on the inlet. In the context of mass balancing, we compared wind related (sampling method 1) and non-wind related (sampling method 2) approaches for measuring CO concentrations. The total volume flow calculations were based on hourly measurements of CO concentrations obtained by Fourier transform infrared (FTIR) spectrometer. Data were collected over a period of six months. The values of the total volume flow were filtered for prevailing southern winds (90 angle). The wind related method (sampling method 1) in stable cross-inflow conditions produces more accurate and realistic values in terms of the general representation of the values in comparison with direct method and can be considered further for measurements of volume flow in the NVBs.