Ilona Sylwia Karpiel

Dr. Ilona Sylwia Karpiel

Łukasiewicz Research Network - Institute of Medical Technology and Equipment, Zabrze, Śląskie, Poland
+4
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
IKIlona Sylwia Karpiel
Ilona Sylwia Karpiel
AZAdam Ziębiński
Adam Ziębiński
Marek KluszczyńskiMarek Kluszczyński
Marek Kluszczyński
DFDaniel Feige
Daniel Feige
The purpose of this article is to present diagnostic methods used in the diagnosis of scoliosis in the form of a brief review. This article aims to point out the advantages of select methods. This article focuses on general issues without elaborating on problems strictly related to physiotherapy and treatment methods, which may be the subject of further discussions. By outlining and categorizing each method, we summarize relevant publications that may not only help introduce other researchers to the field but also be a valuable source for studying existing methods, developing new ones or choosing evaluation strategies.

15 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
IKIlona Sylwia Karpiel
Ilona Sylwia Karpiel
MRMonika Richter-Laskowska
Monika Richter-Laskowska
DFDaniel Feige
Daniel Feige
AGAdam Gacek
Adam Gacek
ASAleksander Sobotnicki
Aleksander Sobotnicki
Accurate and reliable determination of the characteristic points of the impedance cardiogram (ICG) is an important research problem with a growing range of applications in the cardiological diagnostics of patients with heart failure (HF). The shapes of the characteristic waves of the ICG signal and the temporal location of the characteristic points B, C, and X provide significant diagnostic information. On this basis, essential diagnostic cardiological parameters can be determined, such as, e.g., cardiac output (CO) or stroke volume (SV). Although the importance of this problem is obvious, we face many challenges, including noisy signals and the big variability in the morphology, which altogether make the accurate identification of the characteristic points quite difficult. The paper presents an effective method of ICG points identification intended for conducting experimental research in the field of impedance cardiography. Its effectiveness is confirmed in clinical pilot studies.

11 March 2025 in Foods
Verified
Journal Article
Open access
PDF file
MKMirella Kluza
Mirella Kluza
IKIlona Sylwia Karpiel
Ilona Sylwia Karpiel
KDKlaudia Duch
Klaudia Duch
DKDariusz Komorowski
Dariusz Komorowski
SSSzymon Sieciński
Szymon Sieciński
This study evaluates the use of bioimpedance spectroscopy (BIS) as a non-invasive method to assess the freshness of fruits and vegetables by measuring impedance, its components, and phase angle. Over nine days, three vegetables (potato, pumpkin, and red pepper) and two fruits (apple and banana) were assessed using the Analog Discovery 3 device, covering a frequency range of 50 Hz to 1 MHz. The results showed a consistent decrease in impedance and an increase in phase angle during ripening, with statistical significance observed for pumpkin and potato (p < 0.05). The findings confirm BIS as an effective, objective, and non-destructive alternative to traditional chemical methods for monitoring freshness, despite challenges such as structural damage in red pepper. This integration of BIS into food quality assessment and healthcare provides a multidisciplinary approach to improving nutrition and health.

19 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
IKIlona Sylwia Karpiel
Ilona Sylwia Karpiel
ZKZofia Agata Kurasz
Zofia Agata Kurasz
RKRafał Kurasz
Rafał Kurasz
KDKlaudia Duch
Klaudia Duch
The raw EEG signal is always contaminated with many different artifacts, such as muscle movements (electromyographic artifacts), eye blinking (electrooculographic artifacts) or power line disturbances. All artifacts must be removed for correct data interpretation. However, various noise reduction methods significantly influence the final shape of the EEG signal and thus its characteristic values, latency and amplitude. There are several types of filters to eliminate noise early in the processing of EEG data. However, there is no gold standard for their use. This article aims to verify and compare the influence of four various filters (FIR, IIR, FFT, NOTCH) on the latency and amplitude of the EEG signal. By presenting a comparison of selected filters, the authors intend to raise awareness among researchers as regards the effects of known filters on latency and amplitude in a selected area—the sensorimotor area.

11 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
IKIlona Sylwia Karpiel
Ilona Sylwia Karpiel
MMMaciej Mysiński
Maciej Mysiński
KOKamil Olesz
Kamil Olesz
MCMarek Czerw
Marek Czerw
Between 2018 and 2024, the global market has experienced significant advancements in sensor technologies for monitoring patients’ health conditions, which have demonstrated a pivotal role in diagnostics, treatment monitoring, and healthcare optimization. Progress in microelectronics, device miniaturization, and wireless communication technologies has facilitated the development of sophisticated sensors, including wearable devices such as smartwatches and fitness trackers, enabling the real-time monitoring of key health parameters. These devices are widely employed across clinical settings, nursing care, and daily life to collect critical data on vital signs, including heart rate, blood pressure, oxygen saturation, and respiratory rate. A systematic review of the developments within this period highlights the transformative potential of AI and IoT-based technologies in healthcare personalization, particularly in disease symptom prediction and public health management. Furthermore, innovative techniques such as respiratory inductive plethysmography (RIP) and millimeter-wave radar systems (mmTAA) have emerged as precise, non-contact solutions for respiratory monitoring, with applications spanning diagnostics, therapeutic interventions, and enhanced safety in daily life.

21 December 2018 in Journal of Neuroscience Research
Verified
Journal Article
Closed access
PDF file
IKIlona Sylwia Karpiel
Ilona Sylwia Karpiel
UKUwe Klose
Uwe Klose
zofia drzazgazofia drzazga
zofia drzazga