Sumanth Kumar Pavuluri

Dr. Sumanth Kumar Pavuluri


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Sadeque Reza KhanSadeque Reza Khan
Sadeque Reza Khan
SPSumanth Kumar Pavuluri
Sumanth Kumar Pavuluri
Gerard CumminsGerard Cummins
Gerard Cummins
MDMarc Desmulliez
Marc Desmulliez
Wireless power transfer (WPT) systems have become increasingly suitable solutions for the electrical powering of advanced multifunctional micro-electronic devices such as those found in current biomedical implants. The design and implementation of high power transfer efficiency WPT systems are, however, challenging. The size of the WPT system, the separation distance between the outside environment and location of the implanted medical device inside the body, the operating frequency and tissue safety due to power dissipation are key parameters to consider in the design of WPT systems. This article provides a systematic review of the wide range of WPT systems that have been investigated over the last two decades to improve overall system performance. The various strategies implemented to transfer wireless power in implantable medical devices (IMDs) were reviewed, which includes capacitive coupling, inductive coupling, magnetic resonance coupling and, more recently, acoustic and optical powering methods. The strengths and limitations of all these techniques are benchmarked against each other and particular emphasis is placed on comparing the implanted receiver size, the WPT distance, power transfer efficiency and tissue safety presented by the resulting systems. Necessary improvements and trends of each WPT techniques are also indicated per specific IMD.

3 November 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
JFJulia Faerber
Julia Faerber
RGRachael Gregson
Rachael Gregson
RCRichard Clutton
Richard Clutton
Sadeque Reza KhanSadeque Reza Khan
Sadeque Reza Khan
SCSandy Cochran
Sandy Cochran
CCCiaran Connor
Ciaran Connor
This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a $\text{10\,mm\,}\times \,\text{30\,mm}$ capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of –10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10−3 packet error rate and 10−5 bit error rate and no temperature increase of the tissue according to IEEE standards.

3 May 2021 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Open access
KKKonstantinos Kossenas
Konstantinos Kossenas
PSPodilchak Symon
Podilchak Symon
DCDavide Comite
Davide Comite
PRPascual D. Hilario Re
Pascual D. Hilario Re
GGGeorge Goussetis
George Goussetis
MDMarc Desmulliez
Marc Desmulliez
This paper describes an innovative remote surface sterilization approach applicable to the new coronavirus, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The process is based on the application of a liquid film on the surface or object under sterilization (OUS). A beacon signal is used to self-steer the transmitted power from the designed retrodirective antenna array (RDA) towards the OUS using circularly polarized fields; then, the sterilization is completed by raising and maintaining the required temperature for a certain time. Results suggest that the process takes 5 minutes or less for an angular coverage range over 60 degrees whilst abiding by the relevant safety protocols. This paper also models the power incident onto the OUS, providing consistent results with full-wave simulations. A practical RDA system is developed using a 2 × 1 microstrip patch array operating at 2.5 GHz and tested through the positioning of a representative target surface. Measurements, developed by sampling the power transmitted by the heterodyne RDA, are reported for various distances and angles, operating in the near-field of the system. To further validate the methodology, an additional experiment investigating virus deactivation through microwave heating was also developed. Measurements have been performed with an open cavity microwave oven on the Coronavirus (strain 229E) and egg white protein in a cuvette. This demonstrates that the temperature increases of aqueous films up to 70 $^{\circ }$ C by remote microwave-induced heat can denature proteins and deactivate viruses. Possible applications of the method include sterilization of ambulances, medical equipment, and internet of things (IoT) devices.

23 July 2018 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
RARaphael Adamietz
Raphael Adamietz
MDMarc Desmulliez
Marc Desmulliez
SPSumanth Kumar Pavuluri
Sumanth Kumar Pavuluri
TTTim Tilford
Tim Tilford
CBChristopher Bailey
Christopher Bailey
JWJens Warmuth
Jens Warmuth
In this paper, the influence of microwave curing on the reliability of a representative electronic package is examined by reliability testing and measurement of residual stresses. A LM358 voltage regulator die was mounted to an open quad flat no-leads (QFN) package for reliability testing. For the stress measurement, a specifically designed stress measurement die was mounted to the QFN package. The chips were encapsulated with Hysol EO1080 thermosetting polymer material. Curing was performed using an open-ended microwave oven system equipped with in situ temperature control. Three different temperature profiles for microwave curing were selected according to the requested degree of cure and chemical composition of the cured material. A convection cure profile was selected for the control group samples. Temperature cycle tests and highly accelerated stress tests (HAST) were performed on a total number of 80 chips. Ninety-five QFN packages with stress measurement chips were also manufactured. The increased lifetime expectancy of the microwave-cured packaged chips was experimentally demonstrated and measured between the 62% and 149% increased lifetime expectancies after temperature cycle test (TCT), and between 63% and 331% after a HAST and TCT compared to conventionally cured packages. The analysis of specifically designed stress test chips showed significantly lower residual stresses ranging from 26 to 58.3 MPa within the microwave-cured packages compared to conventionally cured packaged chips, which displayed residual stresses ranging from 54 to 80.5 MPa. Therefore, this paper provides additional confidence in the industrial relevance of the microwave curing system and its advantages compared to the traditional convection oven systems.