Tadeusz Sondej

Dr. Tadeusz Sondej

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TSTadeusz Sondej
Tadeusz Sondej
MBMariusz Bednarczyk
Mariusz Bednarczyk
This paper presents an energy-efficient and high-accuracy sampling synchronization approach for real-time synchronous data acquisition in wireless sensor networks (saWSNs). A proprietary protocol based on time-division multiple access (TDMA) and deep energy-efficient coding in sensor firmware is proposed. A real saWSN model based on 2.4 GHz nRF52832 system-on-chip (SoC) sensors was designed and experimentally tested. The obtained results confirmed significant improvements in data synchronization accuracy (even by several times) and power consumption (even by a hundred times) compared to other recently reported studies. The results demonstrated a sampling synchronization accuracy of 0.8 μs and ultra-low power consumption of 15 μW per 1 kb/s throughput for data. The protocol was well designed, stable, and importantly, lightweight. The complexity and computational performance of the proposed scheme were small. The CPU load for the proposed solution was <2% for a sampling event handler below 200 Hz. Furthermore, the transmission reliability was high with a packet error rate (PER) not exceeding 0.18% for TXPWR ≥ −4 dBm and 0.03% for TXPWR ≥ 3 dBm. The efficiency of the proposed protocol was compared with other solutions presented in the manuscript. While the number of new proposals is large, the technical advantage of our solution is significant.

1 December 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RSRyszard Szplet
Ryszard Szplet
PKPawel Kwiatkowski
Pawel Kwiatkowski
KRK. Różyc
K. Różyc
ZJZ. Jachna
Z. Jachna
TSTadeusz Sondej
Tadeusz Sondej
This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

1 April 2019 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
TSTadeusz Sondej
Tadeusz Sondej
KSKrzysztof Sieczkowski
Krzysztof Sieczkowski
RORobert Olszewski
Robert Olszewski
ADAndrzej Dobrowolski
Andrzej Dobrowolski

28 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Piotr ŁubkowskiPiotr Łubkowski
Piotr Łubkowski
JKJaroslaw Krygier
Jaroslaw Krygier
TSTadeusz Sondej
Tadeusz Sondej
ADAndrzej P. Dobrowolski
Andrzej P. Dobrowolski
LALukasz Apiecionek
Lukasz Apiecionek
POPawel Oskwarek
Pawel Oskwarek
The area of military operations is a big challenge for medical support. A particularly important factor that allows medical services to react quickly in the case of mass casualties is the ability to rapidly evacuation of wounded soldiers from a battlefield. To meet this requirement, an effective medical evacuation system is essential. The paper presented the architecture of the electronically supported decision support system for medical evacuation during military operations. The system can also be used by other services such as police or fire service. The system meets the requirements for tactical combat casualty care procedures and is composed of following elements: measurement subsystem, data transmission subsystem and analysis and inference subsystem. The system, based on the continuous monitoring of selected soldiers’ vital signs and biomedical signals, automatically proposes a medical segregation of wounded soldiers (medical triage). The information on the triage was visualized using the Headquarters Management System for medical personnel (first responders, medical officers, medical evacuation groups) and for commanders, if required. All elements of the architecture were described in the paper.

22 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
IJIwona Jannasz
Iwona Jannasz
TSTadeusz Sondej
Tadeusz Sondej
TTTomasz Targowski
Tomasz Targowski
MMMałgorzata Mańczak
Małgorzata Mańczak
KOKarolina Obiała
Karolina Obiała
RORobert Olszewski
Robert Olszewski
Artery stiffness is a risk factor for cardiovascular disease (CVD). The measurement of pulse wave velocity (PWV) between the carotid artery and the femoral artery (cfPWV) is considered the gold standard in the assessment of arterial stiffness. A relationship between cfPWV and regional PWV has not been established. The aim of this study was to evaluate the influence of gender on arterial stiffness measured centrally and regionally in the geriatric population. The central PWV was assessed by a SphygmoCor XCEL, and the regional PWV was assessed by a new device through the photoplethysmographic measurement of multi-site arterial pulse wave velocity (MPPT). The study group included 118 patients (35 males and 83 females; mean age 77.2 ± 8.1 years). Men were characterized by statistically significantly higher values of cfPWV than women (cfPWV 10.52 m/s vs. 9.36 m/s; p = 0.001). In the measurement of regional PWV values using MPPT, no such relationship was found. Gender groups did not statistically differ in the distribution of atherosclerosis risk factors. cfPWV appears to be more accurate than regional PWV in assessing arterial stiffness in the geriatric population.

5 December 2016
Verified
Conference Paper
Closed access
KSKrzysztof Sieczkowski
Krzysztof Sieczkowski
TSTadeusz Sondej
Tadeusz Sondej
ADAndrzej P. Dobrowolski
Andrzej P. Dobrowolski
RORobert Olszewski
Robert Olszewski
This article concerns an autocorrelation algorithm for determining a pulse wave delay. The pulse wave delay is defined as difference between the characteristic points i.e. the difference between the R wave in the electrocardiogram signal (ECG) and distinctive point in the photoplethysmogram (PPG) waveform. Obtaining values of the characteristic points (time stamps) are realized by correlation function. The known values of the time stamps can be used to estimate change of blood pressure. In the proposed algorithm using the autocorrelation function is calculated signal pattern. Then, this pattern is used for further correlation calculations. In the algorithm all the time is analysed the quality of the measured signal. In the next part of article was described method of measurement and the results calculated the time of the characteristic points to determine the pulse wave delay.