Climate change is posing a variety of challenges in the built realm. Among them is the change in future energy consumption and the potential decay of current energy efficient paradigms. Indeed, today’s near-zero Energy buildings (nZEBs) may lose their virtuosity in the near future. The objective of this study is to propose a methodology to evaluate the change in yearly performance between the present situation and future scenarios. Hourly dynamic simulations are performed on a residential nZEB located in Rome, built in compliance with the Italian legislation. We compare the current energy consumption with that expected in 2050, according to the two future projections described in the Fifth Assessment Report (AR5) by the Intergovernmental Panel on Climate Change (IPCC). Implications for thermal comfort are further investigated by assuming no heating and cooling system, and by tracking the free-floating operative temperature. Compared to the current weather conditions, the results reveal an average temperature increase of 3.4 °C and 3.9 °C under RCP4.5 and RCP8.5 scenarios, estimated through ERA-Interim/UrbClim. This comes at the expense of a 47.8% and 50.3% increase in terms of cooling energy needs, and a 129.5% and 185.8% decrease in terms of heating needs. The annual power consumption experiences an 18% increase under both scenarios due to (i) protracted activation of the air conditioning system and (ii) enhanced peak power requirements. A 6.2% and 5.1% decrease in the hours of adaptive comfort is determined under the RCP4.5 and RCP8.5′s 2050 scenarios out of the concerted action of temperature and solar gains. The results for a newly proposed combined index for long-term comfort assessments reveal a milder future penalty, owing to less pronounced excursions and milder daily temperature swings.
In the Mediterranean climate, indoor overheating and, thus, excessive use of cooling systems represents one of the main problems both for the occupants’ health and energy consumption. In order to limit this problem, an appropriate design or energy retrofitting of the building envelope is of utmost importance. The predominance of massive buildings in the Italian territory and the need to comply with Italian regulations often leads technicians to not optimal energy saving solutions. To this purpose, this experimental research was conducted on a mockup building, located in Fabriano and characterized by high thermal mass walls (W0) and two different external insulating systems: Cork based lightweight plaster (W1) and Extruded polystyrene foam panel (XPS) (W2). Furthermore, a virtual model in TRNSYS, a transient simulation software, was used to compare analytical and simulated values. Results show that W2 undergoes a higher level of thermal stress than W1, due to higher peaks in the external surface temperature and larger fluctuations in daily temperature. Therefore, a high value of thermal resistance of the external insulation and low value of external areal heat capacity on a massive building causes external surface overheating problems, thus, not representing the optimal construction solution.
1 September 2019 in IOP Conference Series: Materials Science and Engineering
The EU Directive 2010/31 abstained from prescribing harmonized and strict requirements for nearly Zero Energy Buildings (nZEBs), to provide EU countries flexibility and room for maneuver in setting national targets, in view of the impact of local climatic conditions and specific territorial and socio-economical features on heating and cooling needs. Benchmarks are usually provided in terms of primary energy needs, however the definition of accurate calculation methodologies, notably as regards the cooling share, is a rather challenging task. Nonetheless, its accomplishment is cardinal to countries, like Mediterranean ones, were the building performance is mostly dictated by summertime sensitivities. This paper presents a cutting-edge approach to nZEB performance analysis: the monthly quasi steady-state (EN 13790 as implemented in Italian UNI/TS 11300) and hourly dynamic calculation methods (developed under the standard UNI EN ISO 52016-1:2018) are compared, with due attention to the cooling energy consumption, to spot pros and cons of a finer temporal discretization. Potential nZEB design alternatives in three different Italian climatic zones are contemplated and used to confront the effectiveness of the above procedures.
Living walls (LWs) are bio-based systems with potential to improve indoor air quality (IAQ) by mitigating carbon dioxide (CO2) accumulation. This study experimentally assessed the CO2 phytoremediation performance of two passive LWs installed in a full-scale climatic chamber (4.3 × 3.3 × 2.7 m) and composed of the species Spathiphyllum, Philodendron hederaceum, and Epipremnum aureum. Tests were performed at 20 °C and 24 °C under three lighting levels (LED OFF, LED ON 50 %, and LED ON 100 %) using decay and pulse protocols. Decay tests quantified intrinsic CO2 removal through the decay constant k, half-decay time t1/2, cumulative exposure M, and equivalent airflow rate Q. Under illumination, k increased from 0.00566 min-1 (OFF) to 0.00816 min-1 at 20 °C and 0.01105 min-1 at 24 °C, reducing cumulative exposure by up to 44 %. The equivalent airflow rate increased from 13.0 m3 h-1 (OFF) to 18.8 m3 h-1 and 27.6 m3 h-1 at 20 °C and 24 °C, respectively. Pulse tests simulated the CO2 production of approximately three school-age children and were evaluated relative to the LED OFF condition. The final CO2 increase was reduced by 20% to 27% and 35% to 39% at 20 °C for 50% and 100% LED intensity, and by 26% to 27% and 33% to 37% at 24 ◦C. Under full illumination, the apparent respiratory load decreased from 3.3 to 2.1 occupants. Overall, passive LWs provide a measurable contribution to indoor CO2 mitigation and can complement hybrid ventilation strategies.