The EN ISO 52016-1:2017 standard introduced a new methodology for the hourly calculation of energy needs that allows the study of the dynamic energy performance of buildings. In this study, a comparative analysis was carried out between two heat transfer models for opaque building elements: the one described in the new standard EN ISO 52016-1:2017 (Annex B) and that proposed by the Italian national annex (Annex A). The analysis, carried out on 1854 cases, showed better results for the heating period than for the cooling period, with a lower Root-Mean-Square Error and Coefficient of Variation of the Root-Mean-Square Error for the model proposed by the Italian National Annex. Increasing the performance of the building by decreasing the solar transmission coefficient of the glazed surfaces leads to a worse Root-Mean-Square Error of about 11%. In addition, a sensitivity analysis of the thermo-physical parameters of the opaque building components was carried out and an alternative method for the calculation of the solar transmission coefficient was evaluated. The latter was able to improve the Root-Mean-Square Error of summer solar gains by 46.7% compared to the method proposed by the standard.
To solve the series of heat balances that EN ISO 52016-1 uses to simulate the dynamic hourly energy requirements of a building, detailed climatic data are required as input. Differently from air temperatures, relative humidity and wind speed, which are easily measurable and available in databases, the direct and diffuse solar irradiances incident on the different inclined and oriented surfaces, which are fundamental for the evaluation of solar gains, must be estimated using one of the many regression models available in the literature. Therefore, in this work, the energy needs of buildings were evaluated with the simplified hourly dynamic method of EN ISO 52016-1 by varying the solar irradiance sets on inclined and oriented surfaces obtained from EN ISO 52010-1 and three other pairs of solar irradiance separation and transposition models. Five European locations and two different window solar transmission coefficients (ggl) were analysed. The results showed that on average, for the heating period and for both ggl, the use of the different methods causes an average error on the calculation of the annual demand of less or slightly more than 5%; while for the cooling period, the average error on the calculation of the annual demand is 16.4% for the case study with ggl = 0.28 and 25.1% for the case study with ggl = 0.63. On the other hand, analysing the root-mean-square-error of the hourly data, using the model contained in TRNSYS as a benchmark, for most of the cases, when varying window orientations, cities and ggl, the model that diverges furthest from the others is that contained in EN ISO 52010-1.