Serena Summa

Dr. Serena Summa

Industrial Engineering and Mathematical Sciences Department, Marche Polytechnic University, Ancona, Marche, Italy
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2020 in Climate
Verified
Journal Article
Open access
PDF file
Serena SummaSerena Summa
Serena Summa
LTLuca Tarabelli
Luca Tarabelli
GUGiulia Ulpiani
Giulia Ulpiani
CPCostanzo Di Perna
Costanzo Di Perna
Climate change is posing a variety of challenges in the built realm. Among them is the change in future energy consumption and the potential decay of current energy efficient paradigms. Indeed, today’s near-zero Energy buildings (nZEBs) may lose their virtuosity in the near future. The objective of this study is to propose a methodology to evaluate the change in yearly performance between the present situation and future scenarios. Hourly dynamic simulations are performed on a residential nZEB located in Rome, built in compliance with the Italian legislation. We compare the current energy consumption with that expected in 2050, according to the two future projections described in the Fifth Assessment Report (AR5) by the Intergovernmental Panel on Climate Change (IPCC). Implications for thermal comfort are further investigated by assuming no heating and cooling system, and by tracking the free-floating operative temperature. Compared to the current weather conditions, the results reveal an average temperature increase of 3.4 °C and 3.9 °C under RCP4.5 and RCP8.5 scenarios, estimated through ERA-Interim/UrbClim. This comes at the expense of a 47.8% and 50.3% increase in terms of cooling energy needs, and a 129.5% and 185.8% decrease in terms of heating needs. The annual power consumption experiences an 18% increase under both scenarios due to (i) protracted activation of the air conditioning system and (ii) enhanced peak power requirements. A 6.2% and 5.1% decrease in the hours of adaptive comfort is determined under the RCP4.5 and RCP8.5′s 2050 scenarios out of the concerted action of temperature and solar gains. The results for a newly proposed combined index for long-term comfort assessments reveal a milder future penalty, owing to less pronounced excursions and milder daily temperature swings.

1 March 2019 in Solar Energy
Verified
Journal Article
Closed access
GUGiulia Ulpiani
Giulia Ulpiani
Serena SummaSerena Summa
Serena Summa
CPCostanzo di Perna
Costanzo di Perna

11 May 2024 in Energy and Buildings
Verified
Journal Article
Closed access
ORO. Roig
O. Roig
Serena SummaSerena Summa
Serena Summa
CPC. Pardal
C. Pardal
Antonio IsalgueAntonio Isalgue
Antonio Isalgue
CPC. Di Perna
C. Di Perna
FRANCESCA STAZIFRANCESCA STAZI
FRANCESCA STAZI

29 April 2023 in Energy and Buildings
Verified
Journal Article
Open access
Serena SummaSerena Summa
Serena Summa
GRGiada Remia
Giada Remia
CPC. Di Perna
C. Di Perna
FRANCESCA STAZIFRANCESCA STAZI
FRANCESCA STAZI

15 August 2024 in Building and Environment
Verified
Journal Article
Closed access
Serena SummaSerena Summa
Serena Summa
GRGiada Remia
Giada Remia
CPCostanzo Di Perna
Costanzo Di Perna
FRANCESCA STAZIFRANCESCA STAZI
FRANCESCA STAZI

3 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CTChiara Tribuiani
Chiara Tribuiani
LTLuca Tarabelli
Luca Tarabelli
Serena SummaSerena Summa
Serena Summa
CPCostanzo Di Perna
Costanzo Di Perna
In the Mediterranean climate, indoor overheating and, thus, excessive use of cooling systems represents one of the main problems both for the occupants’ health and energy consumption. In order to limit this problem, an appropriate design or energy retrofitting of the building envelope is of utmost importance. The predominance of massive buildings in the Italian territory and the need to comply with Italian regulations often leads technicians to not optimal energy saving solutions. To this purpose, this experimental research was conducted on a mockup building, located in Fabriano and characterized by high thermal mass walls (W0) and two different external insulating systems: Cork based lightweight plaster (W1) and Extruded polystyrene foam panel (XPS) (W2). Furthermore, a virtual model in TRNSYS, a transient simulation software, was used to compare analytical and simulated values. Results show that W2 undergoes a higher level of thermal stress than W1, due to higher peaks in the external surface temperature and larger fluctuations in daily temperature. Therefore, a high value of thermal resistance of the external insulation and low value of external areal heat capacity on a massive building causes external surface overheating problems, thus, not representing the optimal construction solution.