Alessandra Lucchese

Prof. Alessandra Lucchese

University Milano San Raffaele
+3
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Oral Microbiology
Verified
Journal Article
Open access
Alessandra LuccheseAlessandra Lucchese
Alessandra Lucchese
LBLars Bondemark
Lars Bondemark
MMMarta Marcolina
Marta Marcolina
MMMaurizio Manuelli
Maurizio Manuelli
Background: Oral microbiota has been at the center of cultural attention in recent years. In daily clinical practice, orthodontic appliances may be associated with an increased cariogenic risk and a worsening of preexisting periodontal diseases. Objective: The purpose of this review is to investigate the available evidence regarding the association between orthodontic appliances and changes in the quality and quantity of the oral microbiota. Design: The research included every article published up to October 2017 featuring the keywords ‘Orthodontic appliance* AND (microbiological colonization OR periodontal pathogen* OR Streptococcus mutans OR Lactobacillus spp. OR Candida OR Tannerella forsythia OR Treponema denticola OR Fusobacterium nucleatum OR Aggregatibacter actinomycetemcomitans OR Prevotella intermedia OR Prevotella nigrescens OR Porphyromonas gingivalis)’ and was conducted in the major medical databases. The methodological quality of selected papers was scored using the ‘Swedish Council on Technology Assessment in Health Care Criteria for Grading Assessed Studies’ (SBU) method. Results: Orthodontic appliances influence the oral microbiota with an increase in the counts of S. mutans and Lactobacillus spp. and in the percentage of potentially pathogenic gram-negative bacteria. Conclusions: There is moderate/high evidence regarding the association between orthodontic appliances and changes in the oral microbiota. PROSPERO registration number CRD42018091589.

21 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
Antonino Lo GiudiceAntonino Lo Giudice
Antonino Lo Giudice
VRVincenzo Ronsivalle
Vincenzo Ronsivalle
Cristina GrippaudoCristina Grippaudo
Cristina Grippaudo
Alessandra LuccheseAlessandra Lucchese
Alessandra Lucchese
SMSimone Muraglie
Simone Muraglie
Gaetano IsolaGaetano Isola
Gaetano Isola
The accuracy of 3D reconstructions of the craniomaxillofacial region using cone beam computed tomography (CBCT) is important for the morphological evaluation of specific anatomical structures. Moreover, an accurate segmentation process is fundamental for the physical reconstruction of the anatomy (3D printing) when a preliminary simulation of the therapy is required. In this regard, the objective of this study is to evaluate the accuracy of four different types of software for the semiautomatic segmentation of the mandibular jaw compared to manual segmentation, used as a gold standard. Twenty cone beam computed tomography (CBCT) with a manual approach (Mimics) and a semi-automatic approach (Invesalius, ITK-Snap, Dolphin 3D, Slicer 3D) were selected for the segmentation of the mandible in the present study. The accuracy of semi-automatic segmentation was evaluated: (1) by comparing the mandibular volumes obtained with semi-automatic 3D rendering and manual segmentation and (2) by deviation analysis between the two mandibular models. An analysis of variance (ANOVA) was used to evaluate differences in mandibular volumetric recordings and for a deviation analysis among the different software types used. Linear regression was also performed between manual and semi-automatic methods. No significant differences were found in the total volumes among the obtained 3D mandibular models (Mimics = 40.85 cm3, ITK-Snap = 40.81 cm3, Invesalius = 40.04 cm3, Dolphin 3D = 42.03 cm3, Slicer 3D = 40.58 cm3). High correlations were found between the semi-automatic segmentation and manual segmentation approach, with R coefficients ranging from 0,960 to 0,992. According to the deviation analysis, the mandibular models obtained with ITK-Snap showed the highest matching percentage (Tolerance A = 88.44%, Tolerance B = 97.30%), while those obtained with Dolphin 3D showed the lowest matching percentage (Tolerance A = 60.01%, Tolerance B = 87.76%) (p < 0.05). Colour-coded maps showed that the area of greatest mismatch between semi-automatic and manual segmentation was the condylar region and the region proximate to the dental roots. Despite the fact that the semi-automatic segmentation of the mandible showed, in general, high reliability and high correlation with the manual segmentation, caution should be taken when evaluating the morphological and dimensional characteristics of the condyles either on CBCT-derived digital models or physical models (3D printing).

13 September 2016
Verified
Journal Article
Closed access
Gaetano IsolaGaetano Isola
Gaetano Isola
LRLuca Ramaglia
Luca Ramaglia
GCGiancarlo Cordasco
Giancarlo Cordasco
Alessandra LuccheseAlessandra Lucchese
Alessandra Lucchese
Luca FiorilloLuca Fiorillo
Luca Fiorillo
Giovanni MatareseGiovanni Matarese
Giovanni Matarese
Patients affected by juvenile idiopathic arthritis (JIA) may have several craniofacial growth disturbances and involvements at the temporomandibular joint (TMJ). The objectives of the present study were to evaluate the clinical effectiveness of functional therapy used to reduce asymmetry of mandibular growth and TMJ disorder in patients with JIA. By a retrospective longitudinal design, a cohort of 54 patients with JIA (mean age, 13.2±3.7 years; range, 5-17.7 years) and with TMJ involvements was enrolled in the study. Each patient, following the collection of clinical parameters, was treated for 24 months with a functional appliance individually customized by acrylic resin and resilient stainless steel with posterior and anterior metallic bite planes preventing the teeth from intercuspal contact. To evaluate differences before (T0) and after therapy (T1) of the clinical TMJ parameters, the statistical analysis by the χ2 Test was performed. All the patients completed successfully the study. In patients with JIA, the use of a functional appliance determined a statistically significant difference of the pain during jaw movement, maximal mouth opening, TMJ sounds and crepitations (P<0.001) and TMJ click, significantly reduced at T1 (P<0.05). The use of an orthodontic functional appliance determined a significant improvement, at 24 months, in many TMJ signs and symptoms in patients affected by JIA and with TMJ disorders. This study suggests that children and adolescents with JIA which presented either unilateral or bilateral moderate to severe TMJ involvement, if not treated, should be develop severe disturbances during growing.

1 March 2019 in Minerva Dental and Oral Science
Verified
Journal Article
Closed access
MMMaurizio Manuelli
Maurizio Manuelli
MMMarta Marcolina
Marta Marcolina
NNNico Nardi
Nico Nardi
DBDario Bertossi
Dario Bertossi
DSDaniele De Santis
Daniele De Santis
Alessandra LuccheseAlessandra Lucchese
Alessandra Lucchese
Orthodontic therapy is used to solve numerous oral problems, but the use of fixed oral devices can also impact negatively the oral cavity, if the treatment is not steadily under control. The aim of this study is to evaluate tooth, bone and soft tissues lesions due to the presence of fixed orthodontic appliances. One hundred patients with fixed orthodontic appliances were included in the study. In particular, 20 patients with rapid palatal expander (RPE), 20 patients with Forsus appliance, 20 patients with a fixed multibracket appliance treatment, 20 patients with just the lower vestibular multibracket treatment and 20 patients with both upper and lower vestibular multibracket treatment. An accurate oral examination of the oral cavity, comprehending teeth, bone and soft tissues, was carried out thoroughly, in order to find possible lesions caused by the fixed orthodontic treatment. Concerning RPE, 35% patients had reversible palatal lesions, while 45% patients had the impression of the appliance on the tongue. Periodontal damages were observed in 5% of the patients, as well as tooth lesions (i.e. dental caries). 20% of the patients with Forsus appliance experienced the lesion on the cheek mucosa, while 10% individuals reported periodontal problems, and 15% of the subject suffered for WSL (white spot lesion) and dental caries. Upper vestibular multibracket appliance caused superior labial lesions (15%), cheek mucosal lesions (20%), gingivitis (55%), white spot lesions (WSL) of superior teeth (15%), while dental recessions and periodontitis due to the appliance were rarely observed (5%). Lower vestibular multibracket appliance was frequently the cause of inferior labial lesions (15%), cheek mucosal lesions (15%), gingivitis (50%), WSL of inferior teeth (20%) and also in lower arch dental recessions and periodontitis due to the appliance were rarely observed (5%). Patients with both superior and inferior multibracket appliance experienced upper and/or lower lip lesions (25%), lesions of cheek mucosa (25%), gingivitis (65%) and WSL (30%), and just in few cases periodontitis (10%). Data shows a more critical oral situation in patients with both superior and inferior appliances than people with one-arch therapy. Orthodontic therapy offers a considerable number of advantages, but it is important to underline what may be the adverse consequences also. This allows the orthodontist to inform the patient of all the possible effects of their therapeutic choice. In most cases, RPE can cause an impression of the device on the tongue and reversible lesions of the palate. On the other hand, the orthodontic fixed therapy can cause gingivitis, followed by mucosal lesions, labial lesions and WSL. For these reasons, an accurate assessment of the patients before the application of fixed orthodontic treatment is necessary. Oral hygiene instructions and motivation are very important, as well as periodic controls of the fixed oral device.

1 April 2016
Verified
Journal Article
Closed access
Giovanni MatareseGiovanni Matarese
Giovanni Matarese
Gaetano IsolaGaetano Isola
Gaetano Isola
LRLuca Ramaglia
Luca Ramaglia
DOMENICO DALESSANDRIDOMENICO DALESSANDRI
DOMENICO DALESSANDRI
Alessandra LuccheseAlessandra Lucchese
Alessandra Lucchese
GCGiancarlo Cordasco
Giancarlo Cordasco

10 September 2013 in Progress in Orthodontics
Verified
Journal Article
Open access
PDF file
GCGiancarlo Cordasco
Giancarlo Cordasco
MPMarco Portelli
Marco Portelli
AMAngela Militi
Angela Militi
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
Antonino Lo GiudiceAntonino Lo Giudice
Antonino Lo Giudice
Alessandra LuccheseAlessandra Lucchese
Alessandra Lucchese
Background: The aim of this study was to evaluate the amount of radiation doses absorbed by soft tissues (entrance skin dose) with a low-dose spiral computed tomography (CT) protocol compared to conventional X-ray techniques commonly used in orthodontics. Methods: The amount of skin dose has been evaluated using a tissue-equivalent head-neck radiotherapy humanoid phantom with thermoluminescent dosimeters placed at the level of eye lens, parotid glands, and thyroid glands. CT images have been taken using a Sensation 16 Siemens CT scan and a low-dose protocol (15 mAs, 1 pitch, 2.5 mGy (CTDIvol), 80 kV, 1-mm slice thickness). Results: The difference in image quality between traditional X-ray techniques and low-dose spiral CT was statistically significant (P < 0.05). The difference in mean absorbed dose instead was not statistically significant. Conclusions: Our protocol allows a more accurate orthodontic diagnosis without an increase of radiological risk for the patients in comparison to traditional X-ray techniques.