Antonio Fratini

Dr. Antonio Fratini

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2015 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
Antonio FratiniAntonio Fratini
Antonio Fratini
MSMario Sansone
Mario Sansone
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Mario CesarelliMario Cesarelli
Mario Cesarelli
During last decade the use of ECG recordings in biometric recognition studies has increased. ECG characteristics made it suitable for subject identification: it is unique, present in all living individuals, and hard to forge. However, in spite of the great number of approaches found in literature, no agreement exists on the most appropriate methodology. This study aimed at providing a survey of the techniques used so far in ECG-based human identification. Specifically, a pattern recognition perspective is here proposed providing a unifying framework to appreciate previous studies and, hopefully, guide future research. We searched for papers on the subject from the earliest available date using relevant electronic databases (Medline, IEEEXplore, Scopus, and Web of Knowledge). The following terms were used in different combinations: electrocardiogram, ECG, human identification, biometric, authentication and individual variability. The electronic sources were last searched on 1st March 2015. In our selection we included published research on peer-reviewed journals, books chapters and conferences proceedings. The search was performed for English language documents. 100 pertinent papers were found. Number of subjects involved in the journal studies ranges from 10 to 502, age from 16 to 86, male and female subjects are generally present. Number of analysed leads varies as well as the recording conditions. Identification performance differs widely as well as verification rate. Many studies refer to publicly available databases (Physionet ECG databases repository) while others rely on proprietary recordings making difficult them to compare. As a measure of overall accuracy we computed a weighted average of the identification rate and equal error rate in authentication scenarios. Identification rate resulted equal to 94.95 % while the equal error rate equal to 0.92 %. Biometric recognition is a mature field of research. Nevertheless, the use of physiological signals features, such as the ECG traits, needs further improvements. ECG features have the potential to be used in daily activities such as access control and patient handling as well as in wearable electronics applications. However, some barriers still limit its growth. Further analysis should be addressed on the use of single lead recordings and the study of features which are not dependent on the recording sites (e.g. fingers, hand palms). Moreover, it is expected that new techniques will be developed using fiducials and non-fiducial based features in order to catch the best of both approaches. ECG recognition in pathological subjects is also worth of additional investigations.

4 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Daniele EspositoDaniele Esposito
Daniele Esposito
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
Antonio FratiniAntonio Fratini
Antonio Fratini
GGGaetano Gargiulo
Gaetano Gargiulo
SSSergio Savino
Sergio Savino
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Measurement of muscle contraction is mainly achieved through electromyography (EMG) and is an area of interest for many biomedical applications, including prosthesis control and human machine interface. However, EMG has some drawbacks, and there are also alternative methods for measuring muscle activity, such as by monitoring the mechanical variations that occur during contraction. In this study, a new, simple, non-invasive sensor based on a force-sensitive resistor (FSR) which is able to measure muscle contraction is presented. The sensor, applied on the skin through a rigid dome, senses the mechanical force exerted by the underlying contracting muscles. Although FSR creep causes output drift, it was found that appropriate FSR conditioning reduces the drift by fixing the voltage across the FSR and provides voltage output proportional to force. In addition to the larger contraction signal, the sensor was able to detect the mechanomyogram (MMG), i.e., the little vibrations which occur during muscle contraction. The frequency response of the FSR sensor was found to be large enough to correctly measure the MMG. Simultaneous recordings from flexor carpi ulnaris showed a high correlation (Pearson’s r > 0.9) between the FSR output and the EMG linear envelope. Preliminary validation tests on healthy subjects showed the ability of the FSR sensor, used instead of the EMG, to proportionally control a hand prosthesis, achieving comparable performances.

1 August 2009 in Journal of Electromyography and Kinesiology
Verified
Journal Article
Closed access
Antonio FratiniAntonio Fratini
Antonio Fratini
Mario CesarelliMario Cesarelli
Mario Cesarelli
PBPaolo Bifulco
Paolo Bifulco
MRMaria Romano
Maria Romano

2 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
Jordan BirdJordan Bird
Jordan Bird
MPMichael George Pritchard
Michael George Pritchard
Antonio FratiniAntonio Fratini
Antonio Fratini
AEAniko Ekart
Aniko Ekart
Diego Resende FariaDiego Resende Faria
Diego Resende Faria
Synthetic data augmentation is of paramount importance for machine learning classification, particularly for biological data, which tend to be high dimensional and with a scarcity of training samples. The applications of robotic control and augmentation in disabled and able-bodied subjects still rely mainly on subject-specific analyses. Those can rarely be generalised to the whole population and appear to over complicate simple action recognition such as grasp and release (standard actions in robotic prosthetics and manipulators). We show for the first time that multiple GPT-2 models can machine-generate synthetic biological signals (EMG and EEG) and improve real data classification. Models trained solely on GPT-2 generated EEG data can classify a real EEG dataset at 74.71% accuracy and models trained on GPT-2 EMG data can classify real EMG data at 78.24% accuracy. Synthetic and calibration data are then introduced within each cross validation fold when benchmarking EEG and EMG models. Results show algorithms are improved when either or both additional data are used. A Random Forest achieves a mean 95.81% (1.46) classification accuracy of EEG data, which increases to 96.69% (1.12) when synthetic GPT-2 EEG signals are introduced during training. Similarly, the Random Forest classifying EMG data increases from 93.62% (0.8) to 93.9% (0.59) when training data is augmented by synthetic EMG signals. Additionally, as predicted, augmentation with synthetic biological signals also increases the classification accuracy of data from new subjects that were not observed during training. A Robotiq 2F-85 Gripper was finally used for real-time gesture-based control, with synthetic EMG data augmentation remarkably improving gesture recognition accuracy, from 68.29% to 89.5%.

17 January 2020 in Frontiers in Neurorobotics
Verified
Journal Article
Open access
Daniele EspositoDaniele Esposito
Daniele Esposito
Emilio AndreozziEmilio Andreozzi
Emilio Andreozzi
GGGaetano D. Gargiulo
Gaetano D. Gargiulo
Antonio FratiniAntonio Fratini
Antonio Fratini
GDGiovanni D’aDdio
Giovanni D’aDdio
Paolo BifulcoPaolo Bifulco
Paolo Bifulco
Human Machine Interfaces (HMIs) are employed in a broad range of applications, spanning from assistive devices for disability to remote manipulation and gaming controllers. In this study, a new piezoresistive sensors array armband is proposed for hand gesture recognition. The armband encloses only three sensors targeting specific forearm muscles, with the aim to discriminate eight hand movements. Each sensor is made by a Force Sensitive Resistor (FSR) with a dedicated mechanical coupler and is designed to sense muscle swelling during contraction. The armband is designed to be easily wearable and adjustable for any user and was tested on 10 volunteers. Hand gestures are classified by means of different machine learning algorithms and classification performances are assessed applying both, the 10-fold and leave-one-out cross-validations. A Linear Support Vector Machine provided 96% mean accuracy across all participants. Ultimately, this classifier was implemented on an Arduino platform and allowed successful control for videogames in real-time. The low power consumption together with the high level of accuracy, suggests the potential of this device for exergames commonly employed for neuromotor rehabilitation. The reduced number of sensors makes this HMI also suitable for hand-prosthesis control.

1 February 2018 in Contact Lens and Anterior Eye
Verified
Journal Article
Open access
FMFrancesco Menduni
Francesco Menduni
LDLeon N. Davies
Leon N. Davies
DCDavid Madrid Costa
David Madrid Costa
Antonio FratiniAntonio Fratini
Antonio Fratini
James S. WolffsohnJames S. Wolffsohn
James S. Wolffsohn
To characterise the anatomical parameters of the porcine eye for potentially using it as a laboratory model of dry eye. Anterior chamber depth and angle, corneal curvature, shortest and longest diameter, endothelial cell density, and pachymetry were measured in sixty freshly enucleated porcine eyeballs. Corneal steepest meridian was 7.85±0.32mm, corneal flattest meridian was 8.28±0.32mm, shortest corneal diameter was 12.69±0.58mm, longest corneal diameter was 14.88±0.66mm and central corneal ultrasonic pachymetry was 1009±1μm. Anterior chamber angle was 28.83±4.16°, anterior chamber depth was 1.77±0.27mm, and central corneal thickness measured using OCT was 1248±144μm. Corneal endothelial cell density was 3250±172 cells/mm2. Combining different clinical techniques produced a pool of reproducible data on the porcine eye anatomy, which can be used by researchers to assess the viability of using the porcine eye as an in-vitro/ex-vivo model for dry eye. Due to the similar morphology with the human eye, porcine eyeballs may represent a useful and cost effective model to individually study important key factors in the development of dry eye, such as environmental and mechanical stresses.