Marc Desmulliez

Prof. Marc Desmulliez

Heriot Watt University
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2012 in Circuit World
Verified
Journal Article
Closed access
Gerard CumminsGerard Cummins
Gerard Cummins
MDMarc Desmulliez
Marc Desmulliez
Purpose: The purpose of this paper is to present an exhaustive review of research studies and activities in the inkjet printing of conductive materials.Design/methodology/approach: This paper gives a detailed literature survey of research carried out in inkjet printing of conductive materials.Findings: This article explains the inkjet printing process and the various types of conductive inks. It then examines the various factors that affect the quality of inkjet printed interconnects such as printing parameters, materials and substrate treatments. Methods of characterising both the inkjet printing process and the electrical properties of printed conductive materials are also presented. Finally relevant applications of this technology are described.Originality/value: Inkjet printing is currently one of the cheapest direct write techniques for manufacturing. The use of this technique in electronic manufacturing, where interconnects and other conductive features are required is an area of increasing relevance to the fields of electronics manufacturing, packaging and assembly. This review paper would therefore be of great value and interest to this community.

19 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Sadeque Reza KhanSadeque Reza Khan
Sadeque Reza Khan
SPSumanth Kumar Pavuluri
Sumanth Kumar Pavuluri
Gerard CumminsGerard Cummins
Gerard Cummins
MDMarc Desmulliez
Marc Desmulliez
Wireless power transfer (WPT) systems have become increasingly suitable solutions for the electrical powering of advanced multifunctional micro-electronic devices such as those found in current biomedical implants. The design and implementation of high power transfer efficiency WPT systems are, however, challenging. The size of the WPT system, the separation distance between the outside environment and location of the implanted medical device inside the body, the operating frequency and tissue safety due to power dissipation are key parameters to consider in the design of WPT systems. This article provides a systematic review of the wide range of WPT systems that have been investigated over the last two decades to improve overall system performance. The various strategies implemented to transfer wireless power in implantable medical devices (IMDs) were reviewed, which includes capacitive coupling, inductive coupling, magnetic resonance coupling and, more recently, acoustic and optical powering methods. The strengths and limitations of all these techniques are benchmarked against each other and particular emphasis is placed on comparing the implanted receiver size, the WPT distance, power transfer efficiency and tissue safety presented by the resulting systems. Necessary improvements and trends of each WPT techniques are also indicated per specific IMD.

1 January 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
MMMazher-Iqbal Mohammed
Mazher-Iqbal Mohammed
MDMarc Desmulliez
Marc Desmulliez
This review examines the current state of the art lab-on-a-chip and microfluidic based biosensor technologies used in the detection of cardiac biomarkers. The determination and quantification of blood based, cardiac biomarkers are crucial in the triage and management of a range of cardiac related conditions, where time delay has a major impact on short and longer-term outcomes of a patient. The design and manufacturing of biomarker detection systems are multi-disciplinary in nature and require researchers to have knowledge of both life sciences and engineering for the full potential of this field to be realised. This review will therefore provide a comprehensive overview of chip based immunosensing technology as applied to cardiac biomarker detection, while discussing the potential suitability and limitations of each configuration for incorporation within a clinical diagnostics device suitable for point-of-care applications.

19 June 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
JNJoseph C. Norton
Joseph C. Norton
PSPiotr R. Slawinski
Piotr R. Slawinski
HLHolly Lay
Holly Lay
JMJames W. Martin
James W. Martin
BCBenjamin F. Cox
Benjamin F. Cox
PVPietro Valdastri
Pietro Valdastri
A capsule robot uses magnetic control and microultrasound feedback for in situ autonomous positioning and diagnostics of microanatomy.

1 August 2016 in World Neurosurgery
Verified
Journal Article
Closed access
SMSyed Mahboob
Syed Mahboob
RMRachael McPhillips
Rachael McPhillips
Zhen QiuZhen Qiu
Zhen Qiu
YJYun Jiang
Yun Jiang
CMCarl Meggs
Carl Meggs
SESamy Eljamel
Samy Eljamel

8 May 2009 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
MKMaiwenn KERSAUDY-KERHOAS
Maiwenn KERSAUDY-KERHOAS
RDResham Dhariwal
Resham Dhariwal
MDMarc Desmulliez
Marc Desmulliez
LJLionel Jouvet
Lionel Jouvet