Gaoxuan WANG

Dr. Gaoxuan WANG

Ningbo Research Institute, Zhejiang University, Ningbo 315100, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2024 in Photoacoustics
Verified
Journal Article
Open access
HMHuaiyu Mei
Huaiyu Mei
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
YXYinghe Xu
Yinghe Xu
HHHaijie He
Haijie He
JYJun Yao
Jun Yao
Sailing HeSailing He
Sailing He
Hydrocarbon gas sensing is a challenging task using laser absorption spectroscopy due to the complex and broad structure of absorption lines. This application requires quick, accurate and highly sensitive detection of hydrocarbon gases concentrations. In this paper, a compact photoacoustic spectrophone was developed to simultaneously measure methane, propane and isobutane. This spectrophone uses wavelength modulation spectroscopy (WMS) with a single acoustic resonator and a single DFB laser emitting at 3368 nm, which greatly reduces the system complexity without using time-division multiplexing technology for multi-gas sensing. Due to the complex and broadband absorption of hydrocarbon gases, a novel signal processing method based on multilinear regression with Ridge regression (MLR-RG) is proposed to reduce the measurement error caused by the nonlinearity of spectra signal. For single gas measurement, the detection limits of methane, propane, and isobutane are determined to be 828 ppb, 419 ppb, and 619 ppb (SNR = 1, integration time = 20 s), respectively. For simultaneous multi-gas sensing in a gaseous mixture, the detection limits of propane and isobutane are determined to be 7 ppb, 68 ppb with an integration time of 860 s, 460 s, respectively. The measurement accuracy of propane and isobutane using MLR-RG is higher than that of ordinary least squares regression and partial least squares regression by 75% and 60%, respectively. The proposed algorithm based on MLR-RG provides a promising approach to process the broad overlapping absorption spectra for accurately retrieving hydrocarbon gases concentrations.

13 March 2023 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
YHYan Huang
Yan Huang
TZTie Zhang
Tie Zhang
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
YXYuxin Xing
Yuxin Xing
Sailing HeSailing He
Sailing He
Precise assessment of breath acetone and methane is significant to the medical diagnosis process. A multi-gas sensing system based on wavelength-modulated differential photoacoustic spectroscopy was developed for simultaneous measurement of acetone and methane. A distributed feedback diode laser emitting in the range from 3363 to 3371 nm was employed to scan the absorption lines of acetone and methane. The cross sensitivities in terms of spectral interference among acetone, methane, and water vapor are effectively eliminated by using a linear combination method of reference spectra for accurately determining the concentration of acetone and methane. The positive effect of water vapor on photoacoustic signal resulting from the light absorption of acetone and methane was precisely evaluated. To improve the instrument performance, a differential PA cell companying with a differential amplifier circuit is experimentally demonstrated in providing a better performance of noise suppression compared with a single acoustic resonator. With a low detection limit down to 0.43 ppm and 12 ppb (integration time of 10 s) for acetone and methane, the sensor shows a great potential for medical diagnosis in simultaneous measurement of acetone and methane.

18 June 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FSFengjiao Shen
Fengjiao Shen
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
ZXZhengyue Xue
Zhengyue Xue
TTTu Tan
Tu Tan
ZCZhensong Cao
Zhensong Cao
Weidong ChenWeidong Chen
Weidong Chen
The time constant selected for lock-in amplification (LIA) has a crucial impact on observed line shapes in laser heterodyne spectroscopy, in particular in the case of ground-based remote monitoring of trace gas in the atmospheric column using laser heterodyne radiometer (LHR). Conventional simulation could not allow validation of LHR spectra measured in a real and complex atmospheric environment exhibiting large temporal and spatial variability (humidity, temperature, pressure, etc) that impact significantly the measured LHR spectra profiles. High-precision spectral measurement is thus crucial to avoid any spectral distortion resulting from the measurement. In this paper, the impact of LIA time constant on spectral line shape is investigated for LHR operating in continuous laser tuning mode, based on analysis of laboratory heterodyne spectra, in terms of signal-to-noise ratio (SNR), line width broadening, absorption depth and line shift. With respect to the given frequency scanning speed in continuous mode and to the halfwidth of the absorption feature to scan, a reasonable scanning time ΔTscan, the time needed for scanning laser frequency through the halfwidth ΔνHWHM of the absorption line, equal to or longer than 14 times of the LIA time constant τ is concluded in order to efficiently reduce the noise while without significant shift and distortion of the line shape. Experimental validation was carried out using a laser heterodyne absorption spectroscopy approach in the laboratory. Four different combinations of time constants τ and scanning time ΔTscan were used to record heterodyne spectra of a CH4 absorption line near 1242.00 cm−1 in continuous laser tuning mode. An optimal combination of a scanning time of 137 ms with a time constant of 1 ms was obtained. This optimal combination was used for ground-based measurements of CH4 and N2O in the atmospheric column by LHR. The extracted LHR spectrum is in good agreement with a referenced TCCON (Total Carbon Column Observing Network) FT-IR (Fourier-transform infrared) spectrum.

4 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YJYiming Jiang
Yiming Jiang
TZTie Zhang
Tie Zhang
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
Sailing HeSailing He
Sailing He
A dual-gas photoacoustic spectroscopy (PAS) sensor based on wavelength modulation spectroscopy (WMS) was developed and experimentally demonstrated. Distributed feedback (DFB) laser diodes, emitting at 1512 and 1653 nm, were utilized as the excitation sources for the simultaneous measurement of NH3 and CH4, respectively. The PAS signal was excited by modulating the DFB laser at the first longitudinal resonant frequency of a cylindrical acoustic resonator. Absorption lines for NH3 and CH4 were simultaneously recorded during one frequency scan of the DFB lasers without using any optical switch. The interference of NH3 and CH4 on each other was investigated for accurate detection. The limits of detection (LoDs) of the PAS sensor for NH3 and CH4 for an integration time of 100 s were determined to be 0.1 and 0.3 ppm, respectively. The present PAS sensor provides a new scheme for multi-gas analysis with the advantages of cost-effectiveness, a simple structure and multi-wavelength operation.

29 July 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TZTie Zhang
Tie Zhang
YXYuxin Xing
Yuxin Xing
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
Sailing HeSailing He
Sailing He
An optical system for gaseous chloroform (CHCl3) detection based on wavelength modulation photoacoustic spectroscopy (WMPAS) is proposed for the first time by using a distributed feedback (DFB) laser with a center wavelength of 1683 nm where chloroform has strong and complex absorption peaks. The WMPAS sensor developed possesses the advantages of having a simple structure, high-sensitivity, and direct measurement. A resonant cavity made of stainless steel with a resonant frequency of 6390 Hz was utilized, and eight microphones were located at the middle of the resonator at uniform intervals to collect the sound signal. All of the devices were integrated into an instrument box for practical applications. The performance of the WMPAS sensor was experimentally demonstrated with the measurement of different concentrations of chloroform from 63 to 625 ppm. A linear coefficient R2 of 0.999 and a detection sensitivity of 0.28 ppm with a time period of 20 s were achieved at room temperature (around 20 °C) and atmosphere pressure. Long-time continuous monitoring for a fixed concentration of chloroform gas was carried out to demonstrate the excellent stability of the system. The performance of the system shows great practical value for the detection of chloroform gas in industrial applications.

11 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LWLihui Wang
Lihui Wang
TZTie Zhang
Tie Zhang
YHYan Huang
Yan Huang
YZYuhao Zheng
Yuhao Zheng
Gaoxuan WANGGaoxuan WANG
Gaoxuan WANG
Sailing HeSailing He
Sailing He
A compact photoacoustic spectroscopy system integrated with a non-coaxial multi-pass cell was developed for improving the instrument performance in the measurement of methane. The multi-pass cell with compact light spot mode was proposed for concentrating the light radiation within a limited space, which effectively reduces the instrument dimension. A distributed feedback (DFB) laser with a central wavelength of 1653 nm was employed to excite the photoacoustic signal of methane. A total of 21 round trips of reflection were achieved in an acoustic resonant cavity with a radius of 4 mm and a length of 36 mm. Four microphones were installed around the cavity to collect the signal. An 11-fold enhancement of the photoacoustic signal was achieved through the multi-pass cell, compared to a single-pass cell with dimension of 10 cm. The system was used to measure different concentrations of methane, which showed good linearity. The continuous detection of 10 ppm methane gas was carried out for 6000 s. The Allan standard deviation analysis indicates that the limit of detection of the system was 5.7 ppb with an optimum integration time of 300 s.