Christian Rotsch

Mr. Christian Rotsch

Fraunhofer IWU
+1
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2017 in Materials
Verified
Journal Article
Open access
PDF file
JMJana Markhoff
Jana Markhoff
MKMartin Krogull
Martin Krogull
CSChristian Schulze
Christian Schulze
CRChristian Rotsch
Christian Rotsch
SHSandra Hunger
Sandra Hunger
RBRainer Bader
Rainer Bader
The biomaterials used to maintain or replace functions in the human body consist mainly of metals, ceramics or polymers. In orthopedic surgery, metallic materials, especially titanium and its alloys, are the most common, due to their excellent mechanical properties, corrosion resistance, and biocompatibility. Aside from the established Ti6Al4V alloy, shape memory materials such as nickel-titanium (NiTi) have risen in importance, but are also discussed because of the adverse effects of nickel ions. These might be reduced by specific surface modifications. In the present in vitro study, the osteoblastic cell line MG-63 as well as primary human osteoblasts, fibroblasts, and macrophages were cultured on titanium alloys (forged Ti6Al4V, additive manufactured Ti6Al4V, NiTi, and Diamond-Like-Carbon (DLC)-coated NiTi) to verify their specific biocompatibility and inflammatory potential. Additive manufactured Ti6Al4V and NiTi revealed the highest levels of metabolic cell activity. DLC-coated NiTi appeared as a suitable surface for cell growth, showing the highest collagen production. None of the implant materials caused a strong inflammatory response. In general, no distinct cell-specific response could be observed for the materials and surface coating used. In summary, all tested titanium alloys seem to be biologically appropriate for application in orthopedic surgery.

3 September 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LPLuigi Pelliccia
Luigi Pelliccia
MLMario Lorenz
Mario Lorenz
CHChristoph-E. Heyde
Christoph-E. Heyde
MKMaximilian Kaluschke
Maximilian Kaluschke
PKPhilipp Klimant
Philipp Klimant
NHNiels Hammer
Niels Hammer
Total hip arthroplasty (THA) is a highly successful surgical procedure, but complications remain, including aseptic loosening, early dislocation and misalignment. These may partly be related to lacking training opportunities for novices or those performing THA less frequently. A standardized training setting with realistic haptic feedback for THA does not exist to date. Virtual Reality (VR) may help establish THA training scenarios under standardized settings, morphology and material properties. This work summarizes the development and acquisition of mechanical properties on hip reaming, resulting in a tissue-based material model of the acetabulum for force feedback VR hip reaming simulators. With the given forces and torques occurring during the reaming, Cubic Hermite Spline interpolation seemed the most suitable approach to represent the nonlinear force–displacement behavior of the acetabular tissues over Cubic Splines. Further, Cubic Hermite Splines allowed for a rapid force feedback computation below the 1 ms hallmark. The Cubic Hermite Spline material model was implemented using a three-dimensional-sphere packing model. The resulting forces were delivered via a human–machine-interaction certified KUKA iiwa robotic arm used as a force feedback device. Consequently, this novel approach presents a concept to obtain mechanical data from high-force surgical interventions as baseline data for material models and biomechanical considerations; this will allow THA surgeons to train with a variety of machining hardness levels of acetabula for haptic VR acetabulum reaming.

1 May 2007
Verified
Conference Paper
Closed access
GLGeert Langereis
Geert Langereis
LVLenneke de Voogd-Claessen
Lenneke de Voogd-Claessen
ASArthur Spaepen
Arthur Spaepen
ASAuli Siplia
Auli Siplia
CRChristian Rotsch
Christian Rotsch
TLTorsten Linz
Torsten Linz
The aim of the ConText project is to develop a vest with integrated sensors and electronics for constant monitoring of muscle activity. The vest measures muscle activity in order to derive the psychological stress level of a person. The ConText project proposes to develop a sensor technology, which requires no direct contact with the body, and to achieve a high level of integration of the sensors and electronics into textile. The realisation of contactless EMG sensors, textile integration of the sensors and the creation of a textile substrate with conductive wiring for data transmission and power supply will be the important parts of the project. The prototype will be used for dissemination and application development.

31 January 2018 in JOM
Verified
Journal Article
Closed access
PDF file
TTThomas Töppel
Thomas Töppel
HLHolger Lausch
Holger Lausch
MBMichael Brand
Michael Brand
EHEric Hensel
Eric Hensel
MAMichael Arnold
Michael Arnold
CRChristian Rotsch
Christian Rotsch

18 November 2019 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
MWMichael Werner
Michael Werner
NHNiels Hammer
Niels Hammer
CRChristian Rotsch
Christian Rotsch
IBIsabell Berthold
Isabell Berthold
MLMario Leimert
Mario Leimert

8 January 2018 in Patient Safety in Surgery
Verified
Journal Article
Open access
PDF file
RGRonny Grunert
Ronny Grunert
SSStefan Schleifenbaum
Stefan Schleifenbaum
RMRobert Möbius
Robert Möbius
MKMichael Kopper
Michael Kopper
CRChristian Rotsch
Christian Rotsch
TPTorsten Prietzel
Torsten Prietzel
The modularity in total hip arthroplasty (THA) allows orthopaedic surgeons for an exact reconstruction of hip biomechanical parameters especially in revision and tumor arthroplasty. Modular structured femoral stems using taper junctions showed increased implant breakage in the recent past. We hypothesize that a novel modular stem-neck-interface leads to less implant breakage compared to conventional femoral stems. For this purpose, a novel modular femoral stem for THA was to design and manufacture. Therefore, three different variants of interface mechanisms were developed that enable a simple connection between the stem and the neck modules and allow for intra-operatively adjustment. Three prototypes A, B and C were manufactured and subsequently dynamic fatigue (ISO 7206–6) and body donor tested. Modularity in THA is mainly applied in THA as well as in revision and tumor arthroplasty. Modular implants are barely used because of the high risk of breakage. Another risks in this context are taper fretting, corrosion and disconnection. With the novel design, it should be possible to detach the stem and neck module intra-operatively to adapt the anatomical situation. The novel coupling mechanism of the rotating interface seems to be the most suitable for a secure stem-neck connection and is characterized by good intraoperative handling.