The noninvasive sensing of the blood glucose concentration is usually based on optical, electrical, or acoustical signals induced by blood glucose; these signals are extremely weak and subject to fluctuations caused by the variation in the body or surroundings. Therefore, it is challenging to detect blood glucose noninvasively with high accuracy, and no successful accurate and noninvasive clinical application has been reported. We found that there are two key measurement issues to be addressed: systematic errors, such as the errors induced by the drifts of devices or by variations in body temperature, among others, are too large to guarantee the trueness of measurement at present; and random disturbances in repeated tests, such as disturbances associated with variations in the human–machine interface, pulses, and the thermal noise of the devices, cause larger repeated measurement errors and compromise precision. Recent novel reference measurements based on differential near-infrared (NIR) spectroscopy are considered promising for solving the systematic error issue by establishing matched references, collected at another detection site or at another time, and subsequently differencing to remove the common systematic errors. However, differencing weakens the signal of interest itself and enlarges the effects of the second issue, random disturbances affecting the precision. It is understood that only reference measurements that can meet the precision requirement will be promising for future applications. Therefore, this study quantitatively evaluates the precision of the main differential NIR spectroscopy measurements considering similar conditions and minimized random disturbances. The precision of the measurements under these conditions should represent their optimal precision levels. After the evaluation, noninvasive glucose-sensing methods that hold promise for future clinical application are proposed. Finally, the evaluation criteria could be a reference for the noninvasive detection of other physiological components.

24 May 2022 in Applied Spectroscopy
Verified
Journal Article
Closed access
THTongshuai Han
Tongshuai Han
JLJin Liu
Jin Liu
RLRong Liu
Rong Liu
WCWenliang Chen
Wenliang Chen
MYMingfei Yao
Mingfei Yao
KXKexin Xu
Kexin Xu
In optical noninvasive glucose detection, how to detect the glucose-caused signals from the constant human variations and disturbed probing conditions is always the biggest challenge. Developing effective measurement strategies is essential to realize the detection. A near-infrared (NIR) spectroscopy-based strategy is studied to effectively solve the in vivo measurement issues, obtaining clean blood glucose-caused signals. Two solutions composing our strategy are applied to the NIR spectroscopy-based measurement system to acquire clean raw signals in the data collection, which are a customized high signal-to-noise ratio multi-ring InGaAs detector to reduce the influence of human variations, and a fixing and aiming method to reproduce a consistent measurement condition. Seventeen cases of glucose tolerance test (GTT) on healthy and diabetic volunteers were conducted to validate the strategy. The human experiment results clearly show that the expected blood glucose changes have been detected at 1550 nm. The average correlation coefficient of the 17 cases of GTT between light signal and glucose reference reaches 0.84. The proposed measurement strategy is verified feasible for the glucose detecting in vivo. The strategy provides references to further studies and product developments for the NIR spectroscopy-based glucose measurement and references to other optical measurements in vivo.

10 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
QGQing Ge
Qing Ge
THTongshuai Han
Tongshuai Han
RLRong Liu
Rong Liu
ZZZengfu Zhang
Zengfu Zhang
DSDi Sun
Di Sun
KXKexin Xu
Kexin Xu
In non-invasive blood glucose measurement, the sensitivity of glucose-induced optical signals within human tissue is a crucial reference point. This study evaluates the sensitivity of glucose-induced diffuse reflectance in the 1000–1700 nm range. A key factor in understanding this sensitivity is the rate at which the scattering coefficient changes due to glucose, as it is significantly higher than in non-living media and predominantly influences the diffuse light signal level when blood glucose levels change. The study measured and calculated the changes in the scattering coefficient at 1314 nm, a wavelength chosen for its minimal interference from glucose absorption and other bodily constituents. Based on the Mie scattering theory and the results at 1314 nm, the changes in the scattering coefficient within the 1000–1700 nm range were estimated. Subsequently, the sensitivity of the glucose signal across this range was determined through Monte Carlo (MC) simulations. The findings from 25 human trials indicate that the measured sensitivities at five other typical wavelengths within this band generally align with the sensitivities calculated using the aforementioned method. This research can guide the identification of blood glucose signals and the selection of wavelengths for non-invasive blood glucose measurements.

27 August 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
JLJin Liu
Jin Liu
THTongshuai Han
Tongshuai Han
JJJinying Jiang
Jinying Jiang
KXKexin Xu
Kexin Xu
We present an approach for accurate glucose sensing in turbid media using a spectrally resolved reflectance setup. Our proposed reflectance setup uses specialized source-detector separations (SDSs) to enable an effective separation of diffusion and absorption signals. Additionally, we adjust the selected SDSs to their optimal values to acquire maximum sensitivity to glucose in the two signals. The separation can help to enhance the sensitivity to glucose both for the diffusion and absorption signals, as they always suppress each other by causing opposite effects on the reflected diffuse light intensity. Monte Carlo simulations and experiments for glucose sensing are used to test the method. The acquired optimal SDSs could provide a reference for noninvasive blood glucose sensing.

22 August 2016 in Spectroscopy Letters
Verified
Journal Article
Closed access
ZZZiyang Zhang
Ziyang Zhang
ZCZijin Cai
Zijin Cai
GHGuang Han
Guang Han
WSWeinan Sheng
Weinan Sheng
JLJin Liu
Jin Liu
A method to estimate the absorbance spectrum caused by the variation in the concentration of a substance in a medium at the optimum pathlength for every wavelength on a wide waveband without adjusting the cell’s size precisely was presented in the paper. This spectrum could be used to evaluate the absorption of certain substance at the optimum pathlength at each wavelength, instead of using a uniform pathlength like absorption coefficient. And the absorbance spectra of glucose in aqueous solution at optimum pathlength for every wavelength at 900–2500 nm were estimated by using this method. Moreover, the glucose absorbance spectra show an unexpected result that the absorption peaks at different overtones of the oxygen–hydrogen and carbon–hydrogen bonds are of similar amplitudes.

2 November 2018 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
JLJin Liu
Jin Liu
CZCaigang Zhu
Caigang Zhu
JJJingying Jiang
Jingying Jiang
KXKexin Xu
Kexin Xu
We report a novel approach for the accurate measurement of glucose absorption in turbid media using a spectrally resolved reflectance setup. Our proposed reflectance setup with specialized variable source-detector separations enables scattering-independent absorption measurement, which is critical to in vivo long-term glucose concentration monitoring. Starting from the first-order approximation of the radiative transfer equation (RTE), we developed a scattering-independent glucose absorption measurement method and then evaluated this approach by Monte Carlo simulations as well as tissue-mimicking phantom studies in which glucose concentration was accurately measured. Our study demonstrates the potential of our proposed scattering-independent absorption measurement technique as an effective tool to quantify glucose levels in turbid media, which is an important step towards future in vivo long-term glucose concentration monitoring in human subjects.