Khosro Fallahnezhad

Mr. Khosro Fallahnezhad

Medical Device Research Institute, College of Science and Engineering, Flinders University, 1284 South Road, Clovelly Park, SA 5042, Australia

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Khosro FallahnezhadKhosro Fallahnezhad
Khosro Fallahnezhad
Reza HashemiReza Hashemi
Reza Hashemi
HBHojjat Badnava
Hojjat Badnava
MTMark Taylor
Mark Taylor

1 September 2018 in Finite Elements in Analysis and Design
Verified
Journal Article
Closed access
Khosro FallahnezhadKhosro Fallahnezhad
Khosro Fallahnezhad
Reza HashemiReza Hashemi
Reza Hashemi
MTMark Taylor
Mark Taylor

1 July 2016 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Khosro FallahnezhadKhosro Fallahnezhad
Khosro Fallahnezhad
HFHamidreza Farhoudi
Hamidreza Farhoudi
Reza HashemiReza Hashemi
Reza Hashemi
MTMark Taylor
Mark Taylor

1 April 2019 in Wear
Verified
Journal Article
Closed access
Khosro FallahnezhadKhosro Fallahnezhad
Khosro Fallahnezhad
SLSheng Liu
Sheng Liu
OBOsama Brinji
Osama Brinji
MMMalcolm Marker
Malcolm Marker
PMPaul A. Meehan
Paul A. Meehan

1 November 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
HFHamidreza Farhoudi
Hamidreza Farhoudi
Khosro FallahnezhadKhosro Fallahnezhad
Khosro Fallahnezhad
Reza HashemiReza Hashemi
Reza Hashemi
MTMark Taylor
Mark Taylor
This paper investigates the mechanical response of a modular head-neck interface of hip joint implants under realistic loads of level walking. The realistic loads of the walking activity consist of three dimensional gait forces and the associated frictional moments. These forces and moments were extracted for a 32mm metal-on-metal bearing couple. A previously reported geometry of a modular CoCr/CoCr head-neck interface with a proximal contact was used for this investigation. An explicit finite element analysis was performed to investigate the interface mechanical responses. To study the level of contribution and also the effect of superposition of the load components, three different scenarios of loading were studied: gait forces only, frictional moments only, and combined gait forces and frictional moments. Stress field, micro-motions, shear stresses and fretting work at the contacting nodes of the interface were analysed. Gait forces only were found to significantly influence the mechanical environment of the head-neck interface by temporarily extending the contacting area (8.43% of initially non-contacting surface nodes temporarily came into contact), and therefore changing the stress field and resultant micro-motions during the gait cycle. The frictional moments only did not cause considerable changes in the mechanical response of the interface (only 0.27% of the non-contacting surface nodes temporarily came into contact). However, when superposed with the gait forces, the mechanical response of the interface, particularly micro-motions and fretting work, changed compared to the forces only case. The normal contact stresses and micro-motions obtained from this realistic load-controlled study were typically in the range of 0-275MPa and 0-38µm, respectively. These ranges were found comparable to previous experimental displacement-controlled pin/cylinder-on-disk fretting corrosion studies.

1 January 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
Khosro FallahnezhadKhosro Fallahnezhad
Khosro Fallahnezhad
HFHamidreza Farhoudi
Hamidreza Farhoudi
Reza HashemiReza Hashemi
Reza Hashemi
MTMark Taylor
Mark Taylor
A finite element model was developed to investigate the effect of loading regimes caused by various daily activities on the mechanical behaviour of the head-neck taper junction in modular hip replacements. The activities included stair up, stair down, sit to stand, stand to sit, one leg standing and knee bending. To present the real mechanical environment of the junction, in addition to the force components, the frictional moments produced by the frictional sliding of the head and cup were applied to a CoCr/CoCr junction having a 12/14 taper with a proximal mismatch angle of 0.024°. This study revealed that stair up with the highest fretting work per unit of length (1.62 × 104J/m) was the most critical activity, while knee bending and stand to sit with 1.96 × 103J/m were the least critical activities. For all the activities, the superolateral region of the neck was identified as the most critical region in terms of having larger values of fretting work per unit of area. This study showed also that the relative micro-motions and contact stresses occurring at the head-neck interface for all the studied activities are mostly in the range of 0-38µm and 0-350MPa, respectively. These ranges may be accordingly employed for conducting relevant in-vitro tests to more realistically represent the mechanical environment of taper junctions with the same materials and geometry studied in this work.