Gurcan ATAKOK

Dr. Gurcan ATAKOK

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2022 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
GAGurcan ATAKOK
Gurcan ATAKOK
Menderes KAMMenderes KAM
Menderes KAM
Hanife Bukre KOÇ GÜNEŞSUHanife Bukre KOÇ GÜNEŞSU
Hanife Bukre KOÇ GÜNEŞSU

1 September 2009 in Materials & Design (1980-2015)
Verified
Journal Article
Closed access
MKMustafa Kurt
Mustafa Kurt
OKO. Saban Kamber
O. Saban Kamber
YKYusuf Kaynak
Yusuf Kaynak
GAGurcan ATAKOK
Gurcan ATAKOK
OGOguz Girit
Oguz Girit

18 December 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
GAGurcan ATAKOK
Gurcan ATAKOK
DYDUDU MERTGENÇ YOLDAŞ
DUDU MERTGENÇ YOLDAŞ
Macroscopic structures consisting of two or more materials are called composites. The decreasing reserves of the world’s oil reserve and the environmental pollution of existing energy and production resources made the use of recycling methods inevitable. There are mechanical, thermal, and chemical recycling methods for the recycling of thermosets among composite materials. The recycling of thermoset composite materials economically saves resources and energy in the production of reinforcement and matrix materials. Due to the superior properties such as hardness, strength, lightness, corrosion resistance, design width, and the flexibility of epoxy/vinylester/polyester fibre formation composite materials combined with thermoset resin at the macro level, environmentally friendly sustainable development is happening with the increasing use of composite materials in many fields such as the maritime sector, space technology, wind energy, the manufacturing of medical devices, robot technology, the chemical industry, electrical electronic technology, the construction and building sector, the automotive sector, the defence industry, the aviation sector, the food and agriculture sector, and sports equipment manufacturing. Bonded joint studies in composite materials have generally been investigated at the level of a single composite material and single joint. The uncertainty of the long-term effects of different composite materials and environmental factors in single-lap bonded joints is an important obstacle in applications. The aim of this study is to investigate the effects of single-lap bonded GFRP (glass fibre-reinforced polymer) and CFRP (carbon fibre-reinforced polymer) specimens on the material at the end of seawater exposure. In this study, 0/90 orientation twill weave seven-ply GFRP and eight-ply CFRP composite materials were used in dry conditions (without seawater soaking) and the hand lay-up method. Seawater was taken from the Aegean Sea, İzmir province (Selçuk/Pamucak), in September at 23.5 °C. This seawater was kept in different containers in seawater for 1 month (30 days), 2 months (60 days), and 3 months (90 days) separately for GFRP and CFRP composite samples. They were cut according to ASTM D5868-01 for single-lap joint connections. Moisture retention percentages and axial impact tests were performed. Three-point bending tests were then performed according to ASTM D790. Damage to the material was examined with a ZEISS GEMINESEM 560 scanning electron microscope (SEM). The SEM was used to observe the interface properties and microstructure of the fracture surfaces of the composite samples by scanning images with a focused electron beam. Damage analysis imaging was performed on CFRP and GFRP specimens after sputtering with a gold compound. Moisture retention rates (%), axial impact tests, and three-point bending test specimens were kept in seawater with a seawater salinity of 3.3–3.7% and a seawater temperature of 23.5 °C for 1, 2, and 3 months. Moisture retention rates (%) are 0.66%, 3.43%, and 4.16% for GFRP single-lap bonded joints in a dry environment and joints kept for 1, 2, and 3 months, respectively. In CFRP single-lap bonded joints, it is 0.57%, 0.86%, and 0.87%, respectively. As a result of axial impact tests, under a 30 J impact energy level, the fracture toughness of GFRP single-lap bonded joints kept in a dry environment and seawater for 1, 2, and 3 months are 4.6%, 9.1%, 14.7%, and 11.23%, respectively. At the 30 J impact energy level, the fracture toughness values of CFRP single-lap bonded joints in a dry environment and in seawater for 1, 2, and 3 months were 4.2%, 5.3%, 6.4%, and 6.1%, respectively. As a result of three-point bending tests, GFRP single-lap joints showed a 5.94%, 8.90%, and 12.98% decrease in Young’s modulus compared to dry joints kept in seawater for 1, 2, and 3 months, respectively. CFRP single-lap joints showed that Young’s modulus decreased by 1.28%, 3.39%, and 3.74% compared to dry joints kept in seawater for 1, 2, and 3 months, respectively. Comparing the GFRP and CFRP specimens formed by a single-lap bonded connection, the moisture retention percentages of GFRP specimens and the amount of energy absorbed in axial impact tests increased with the soaking time in seawater, while Young’s modulus was less in three-point bending tests, indicating that CFRP specimens have better mechanical properties.

14 May 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MEHMET AKİF KARTALMEHMET AKİF KARTAL
MEHMET AKİF KARTAL
GAGurcan ATAKOK
Gurcan ATAKOK
Sezgin ErsoySezgin Ersoy
Sezgin Ersoy
Cooling processes are responsible for a significant portion (20%) of global energy consumption and raise environmental concerns such as ozone depletion, the greenhouse effect, and high energy use. This study investigates the potential of R152a, a refrigerant with low global warming potential (GWP), as a more sustainable alternative. The performance, safety, and operational efficiency of R152a were evaluated under various conditions. Although R152a offers high performance and low GWP, its flammability necessitates caution, especially in certain mixtures. A 12-pass tube-type heat exchanger model was simulated using computational fluid dynamics (CFD) to analyze the fluid behavior within the exchanger. The pressure, density, dynamic pressure, Prandtl number, total pressure, and temperature distributions for both R152a and H2O (water) were visualized using contour plots. The simulations comprehensively examined the fluid behavior inside and outside the heat exchanger. The results revealed the influence of the temperature on the internal dynamic pressure and density of R152a. Compared with R134a, R152a demonstrated superior performance but a lower coefficient of performance (COP) than R32. Studies also suggest that R152a exhibits lower irreversibility in Organic Rankine Cycle (ORC) systems than R245fa. These findings suggest that R152a holds promise for future refrigeration systems, as supported by existing research on its performance and compatibility. One study focused on optimizing the heat exchanger performance by maximizing the heat capacity and minimizing the pressure drop. This study employed a parallel-flow heat exchanger with R152a as the coolant for the hot process water. The temperature changes, pressure drops, and resulting energy efficiency and thermal performance of both fluids were analyzed. The results highlight the distinct energy efficiencies and thermal performance of the employed fluids.
1

24 March 2025 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
GAGurcan ATAKOK
Gurcan ATAKOK
DYDudu Mertgenc Yoldas
Dudu Mertgenc Yoldas
Composites consisting of two or more different macroscopic structures are becoming increasingly popular. This study investigates the long-term effects of single lap-joined GFRP and CFRP specimens on the material after exposure to seawater. Seven-ply GFRP and eight-ply CFRP composite materials were used under dry (without immersion in sea water) conditions and by hand lay-up method. Both GFRP and CFRP samples were 0/90 oriented twill braided. In September, sea water at 23.5°C temperature in Izmir province (Selçuk/Pamucak) region was kept in different containers for 1 month (30 days), 2 months (60 days), and 3 months (90 days) separately for GFRP and CFRP composites. They were cut for single lap joints according to ASTM D5868-01. Axial impact tests and moisture retention percentages were performed. Three-point bending tests were then performed in accordance with ASTM D790. Moisture retention rates (%), axial impact tests, and three point bending test specimens were kept in seawater with 3.3%–3.7% salinity for 1, 2, and 3 months. As a result of the three-point bending tests, it was observed that the Young modulus of the GFRP single lap joints decreased by 5.94%, 8.90%, and 12.98%, respectively, compared to the dry joints held for 1, 2, and 3 months. It was observed that the Young modulus of the CFRP single lap joints decreased by 1.28%, 3.39%, and 3.74%, respectively, compared to the dry joints held for 1, 2, and 3 months.

11 September 2020 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
OGOguz Girit
Oguz Girit
GAGurcan ATAKOK
Gurcan ATAKOK
Sezgin ErsoySezgin Ersoy
Sezgin Ersoy
Vibration and temperature data of a servo motor are analyzed with PLC which is widely used in the industry. With this system, power supply can be detected on the servo motors. In this way, undesirable situations such as disruptions in production and productivity loss can be prevented from occurring. It is an important problem for businesses to detect malfunctions that may occur in servo motor dysfunction. Previously, methods such as ultrasonic sound measurements, thermal cameras, endoscopy equipment, and energy analysis have been used and discussed in the literature. Our study offers a PLC-based vibration and temperature measurement system designed as a solution of this problem. In this system, vibration and temperature measurements were made while the servo motor was kept running. These measurements were measured with or without load, considering the operating ranges of the servo motor, and the compatibility of the data was evaluated.