Joan Nunez do Rio

Dr. Joan Nunez do Rio

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JRJoan Nunez do Rio
Joan Nunez do Rio
PSPiyali Sen
Piyali Sen
RRRajna Rasheed
Rajna Rasheed
ABAkanksha Bagchi
Akanksha Bagchi
LNLuke Nicholson
Luke Nicholson
SSSobha Sivaprasad
Sobha Sivaprasad
Reliable outcome measures are required for clinical trials investigating novel agents for preventing progression of capillary non-perfusion (CNP) in retinal vascular diseases. Currently, accurate quantification of topographical distribution of CNP on ultrawide field fluorescein angiography (UWF-FA) by retinal experts is subjective and lack standardisation. A U-net style network was trained to extract a dense segmentation of CNP from a newly created dataset of 75 UWF-FA images. A subset of 20 images was also segmented by a second expert grader for inter-grader reliability evaluation. Further, a circular grid centred on the FAZ was used to provide standardised CNP distribution analysis. The model for dense segmentation was five-fold cross-validated achieving area under the receiving operating characteristic of 0.82 (0.03) and area under precision-recall curve 0.73 (0.05). Inter-grader assessment on the 20 image subset achieves: precision 59.34 (10.92), recall 76.99 (12.5), and dice similarity coefficient (DSC) 65.51 (4.91), and the centred operating point of the automated model reached: precision 64.41 (13.66), recall 70.02 (16.2), and DSC 66.09 (13.32). Agreement of CNP grid assessment reached: Kappa 0.55 (0.03), perfused intraclass correlation (ICC) 0.89 (0.77, 0.93), non-perfused ICC 0.86 (0.73, 0.92), inter-grader agreement of CNP grid assessment values are Kappa 0.43 (0.03), perfused ICC 0.70 (0.48, 0.83), non-perfused ICC 0.71 (0.48, 0.83). Automated dense segmentation of CNP in UWF-FA images achieves performance levels comparable to inter-grader agreement values. A grid placed on the deep learning-based automatic segmentation of CNP generates a reliable and quantifiable method of measurement of CNP, to overcome the subjectivity of human graders.

26 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JRJoan Nunez do Rio
Joan Nunez do Rio
PNPaul Nderitu
Paul Nderitu
CBChristos Bergeles
Christos Bergeles
SSSobha Sivaprasad
Sobha Sivaprasad
GTGavin S. W. Tan
Gavin S. W. Tan
Rajiv RamanRajiv Raman
Rajiv Raman
Artificial Intelligence has showcased clear capabilities to automatically grade diabetic retinopathy (DR) on mydriatic retinal images captured by clinical experts on fixed table-top retinal cameras within hospital settings. However, in many low- and middle-income countries, screening for DR revolves around minimally trained field workers using handheld non-mydriatic cameras in community settings. This prospective study evaluated the diagnostic accuracy of a deep learning algorithm developed using mydriatic retinal images by the Singapore Eye Research Institute, commercially available as Zeiss VISUHEALTH-AI DR, on images captured by field workers on a Zeiss Visuscout® 100 non-mydriatic handheld camera from people with diabetes in a house-to-house cross-sectional study across 20 regions in India. A total of 20,489 patient eyes from 11,199 patients were used to evaluate algorithm performance in identifying referable DR, non-referable DR, and gradability. For each category, the algorithm achieved precision values of 29.60 (95% CI 27.40, 31.88), 92.56 (92.13, 92.97), and 58.58 (56.97, 60.19), recall values of 62.69 (59.17, 66.12), 85.65 (85.11, 86.18), and 65.06 (63.40, 66.69), and F-score values of 40.22 (38.25, 42.21), 88.97 (88.62, 89.31), and 61.65 (60.50, 62.80), respectively. Model performance reached 91.22 (90.79, 91.64) sensitivity and 65.06 (63.40, 66.69) specificity at detecting gradability and 72.08 (70.68, 73.46) sensitivity and 85.65 (85.11, 86.18) specificity for the detection of all referable eyes. Algorithm accuracy is dependent on the quality of acquired retinal images, and this is a major limiting step for its global implementation in community non-mydriatic DR screening using handheld cameras. This study highlights the need to develop and train deep learning-based screening tools in such conditions before implementation.

20 December 2025 in Communications Medicine
Verified
Journal Article
Open access
PDF file
PNPaul Nderitu
Paul Nderitu
JRJoan Nunez do Rio
Joan Nunez do Rio
LWLaura Webster
Laura Webster
SMSamantha S. Mann
Samantha S. Mann
DHDavid Hopkins
David Hopkins
TJTimothy L. Jackson
Timothy L. Jackson
Background: Labelled data scarcity and class imbalance are common deep learning system (DLS) development challenges. We investigated if synthetic retinal images from a conditional cascaded diffusion model (CCDM) improves prognostic DLS (pDLS) performance for 2-year incident referable diabetic retinopathy or maculopathy (rDR/rM) prediction. Methods: Macula images from 72,559 eyes (September 2013 to December 2019) from the UK South-East London Diabetic Eye Screening Programme (SEL-DESP) formed the development dataset, whilst 9,071 eyes were used for internal testing. Images from 2,842 eyes from Birmingham DESP were used for external testing. Prognostic DLS were augmented with ×1, ×2, and ×4 additional synthetic positive cases (pDLS-G) and compared to unaugmented (pDLS-N) and ×1 positive-case resampled pDLS (pDLS-R) using the Area-Under-the Receiver Operating Characteristic curve (AUROC). Results: Here we show that CCDM generate realistic synthetic retinal images that are comparable to real images and demonstrate the utility of synthetic retinal images in augmenting the development of a pDLS. The internal and external test AUROC for the pDLS are 0.827 (95% CI: 0.794–0.861) and 0.756 (0.680–0.831), respectively. Augmentation with ×2 additional synthetic positive cases (pDLS-G ×2) significantly improves the internal test AUROC to 0.845 (95% CI: 0.812–0.877, p = 0.044) but does not improve the external test AUROC 0.717 (0.633–0.828, p = 0.243). Resampling positive real cases alone does not improve pDLS-R performance. Conclusions: Augmenting pDLS with synthetic retinal images significantly improves pDLS performance on internal testing but not external testing suggesting further research is required to enhance the generalisability of synthetic retinal image augmentation.

10 September 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
GZGongyu Zhang
Gongyu Zhang
ZCZe Chen
Ze Chen
JHJiayu Huo
Jiayu Huo
JRJoan Nunez do Rio
Joan Nunez do Rio
CKCharalampos Komninos
Charalampos Komninos
TJTimothy L. Jackson
Timothy L. Jackson
Domain generalization techniques involve training a model on one set of domains and evaluating its performance on different, unseen domains. In contrast, test-time adaptation optimizes the model specifically for the target domain during inference. Both approaches improve diagnostic accuracy in medical imaging models. However, no research to date has leveraged the advantages of both approaches in an end-to-end fashion. Our paper introduces RetiGen, a test-time optimization framework designed to be integrated with existing domain generalization approaches. With an emphasis on the ophthalmic imaging domain, RetiGen leverages unlabeled multi-view color fundus photographs-a critical optical technology in retinal diagnostics. By utilizing information from multiple viewing angles, our approach significantly enhances the robustness and accuracy of machine learning models when applied across different domains. By integrating class balancing, test-time adaptation, and a multi-view optimization strategy, RetiGen effectively addresses the persistent issue of domain shift, which often hinders the performance of imaging models. Experimental results demonstrate that our method outperforms state-of-the-art techniques in both domain generalization and test-time optimization. Specifically, RetiGen increases the generalizability of the MFIDDR dataset, improving the AUC from 0.751 to 0.872, a 0.121 improvement. Similarly, for the DRTiD dataset, the AUC increased from 0.794 to 0.879, a 0.085 improvement. The code for RetiGen is publicly available at https://github.com/RViMLab/RetiGen.