1 April 2022 in International Journal of Computer Assisted Radiology and Surgery
Purpose: Intra-retinal delivery of novel sight-restoring therapies will require the precision of robotic systems accompanied by excellent visualisation of retinal layers. Intra-operative Optical Coherence Tomography (iOCT) provides cross-sectional retinal images in real time but at the cost of image quality that is insufficient for intra-retinal therapy delivery.This paper proposes a super-resolution methodology that improves iOCT image quality leveraging spatiotemporal consistency of incoming iOCT video streams.Methods: To overcome the absence of ground truth high-resolution (HR) images, we first generate HR iOCT images by fusing spatially aligned iOCT video frames. Then, we automatically assess the quality of the HR images on key retinal layers using a deep semantic segmentation model. Finally, we use image-to-image translation models (Pix2Pix and CycleGAN) to enhance the quality of LR images via quality transfer from the estimated HR domain.Results: Our proposed methodology generates iOCT images of improved quality according to both full-reference and no-reference metrics. A qualitative study with expert clinicians also confirms the improvement in the delineation of pertinent layers and in the reduction of artefacts. Furthermore, our approach outperforms conventional denoising filters and the learning-based state-of-the-art.Conclusions: The results indicate that the learning-based methods using the estimated, through our pipeline, HR domain can be used to enhance the iOCT image quality. Therefore, the proposed method can computationally augment the capabilities of iOCT imaging helping this modality support the vitreoretinal surgical interventions of the future.
16 January 2024 in Biomedical Optics Express
Regenerative therapies show promise in reversing sight loss caused by degenerative eye diseases. Their precise subretinal delivery can be facilitated by robotic systems alongside with Intra-operative Optical Coherence Tomography (iOCT). However, iOCT’s real-time retinal layer information is compromised by inferior image quality. To address this limitation, we introduce an unpaired video super-resolution methodology for iOCT quality enhancement. A recurrent network is proposed to leverage temporal information from iOCT sequences, and spatial information from pre-operatively acquired OCT images. Additionally, a patchwise contrastive loss enables unpaired super-resolution. Extensive quantitative analysis demonstrates that our approach outperforms existing state-of-the-art iOCT super-resolution models. Furthermore, ablation studies showcase the importance of temporal aggregation and contrastive loss in elevating iOCT quality. A qualitative study involving expert clinicians also confirms this improvement. The comprehensive evaluation demonstrates our method’s potential to enhance the iOCT image quality, thereby facilitating successful guidance for regenerative therapies.
30 November 2025 in Clinical and Experimental Otorhinolaryngology
Objectives. The primary objective was to determine which of the following angular insertion depth (AID) estimation methods showed the strongest correlation with the postoperative AID (AIDpostop) of a lateral wall (LW) electrode: the Escudé formula, based on the largest distance from the round window (RW) to the LW (distance A); the elliptic-circular approximation (ECA) method, based on both distance A and the perpendicular distance (distance B); and a three-dimensional (3D) reconstruction method. The secondary objective was to assess the impact of using the actual electrode insertion length on the evaluation of AID estimation methods.Methods. This study included 45 cochleae implanted with the Advanced Bionics SlimJ electrode, with all 16 active electrode contacts positioned intracochlear. Distance A, distance B, and a 3D reconstruction along the LW were evaluated on preoperative magnetic resonance imaging using 3D Slicer. The AIDpostop and insertion length were assessed using cone-beam computed tomography. Two sets of estimated AID values were obtained: assuming a perfect 23-mm insertion length with the reference electrode at the RW (AID23mm); and using the actual insertion length (AIDinsertionlength). Spearman’s rank correlation coefficient was used to assess the association between the estimated AID values and AIDpostop.Results. A moderately positive correlation was observed between AID23mm and AIDpostop for all three approaches, with no statistically significant differences among them (rs=0.410–0.579). When the analysis was repeated using AIDinsertionlength, the strength of the correlation with AIDpostop increased significantly for all three methods, with the 3D reconstruction method showing a stronger correlation (rs=0.952) than the Escudé formula (rs=0.734) or the ECA method (rs=0.787) (P<0.001).Conclusion. The 3D reconstruction approach has the potential to improve prediction of the AID for LW electrode arrays compared to spiral formulae based on 2D cochlear dimensions. Accurate assessment of the actual insertion length is important for the proper evaluation of AID estimation methods.
10 September 2025 in Computers in Biology and Medicine
Domain generalization techniques involve training a model on one set of domains and evaluating its performance on different, unseen domains. In contrast, test-time adaptation optimizes the model specifically for the target domain during inference. Both approaches improve diagnostic accuracy in medical imaging models. However, no research to date has leveraged the advantages of both approaches in an end-to-end fashion. Our paper introduces RetiGen, a test-time optimization framework designed to be integrated with existing domain generalization approaches. With an emphasis on the ophthalmic imaging domain, RetiGen leverages unlabeled multi-view color fundus photographs-a critical optical technology in retinal diagnostics. By utilizing information from multiple viewing angles, our approach significantly enhances the robustness and accuracy of machine learning models when applied across different domains. By integrating class balancing, test-time adaptation, and a multi-view optimization strategy, RetiGen effectively addresses the persistent issue of domain shift, which often hinders the performance of imaging models. Experimental results demonstrate that our method outperforms state-of-the-art techniques in both domain generalization and test-time optimization. Specifically, RetiGen increases the generalizability of the MFIDDR dataset, improving the AUC from 0.751 to 0.872, a 0.121 improvement. Similarly, for the DRTiD dataset, the AUC increased from 0.794 to 0.879, a 0.085 improvement. The code for RetiGen is publicly available at https://github.com/RViMLab/RetiGen.