Tae-Heon Yang

Prof. Tae-Heon Yang

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2019 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
TYTae-Heon Yang
Tae-Heon Yang
GJGwanghyun Jo
Gwanghyun Jo
JKJeong-Hoi Koo
Jeong-Hoi Koo
SWSamYong Woo
SamYong Woo
Jaeuk KimJaeuk Kim
Jaeuk Kim
YKYoung-Min Kim
Young-Min Kim
There exists a growing need for a cost-effective, reliable, and portable pulsation simulator that can generate a wide variety of pulses depending on age and cardiovascular disease. For constructing compact pulsation simulator, this study proposes to use a pneumatic actuator based on cam-follower mechanism controlled by a DC motor. The simulator is intended to generate pulse waveforms for a range of pulse pressures and heart beats that are realistic to human blood pulsations. This study first performed in vivo testing of a healthy young man to collect his pulse waveforms using a robotic tonometry system (RTS). Based on the collected data a representative human radial pulse waveform is obtained by conducting a mathematical analysis. This standard pulse waveform is then used to design the cam profile. Upon fabrication of the cam, the pulsatile simulator, consisting of the pulse pressure generating component, pressure and heart rate adjusting units, and the real-time pulse display, is constructed. Using the RTS, a series of testing was performed on the prototype to collect its pulse waveforms by varying the pressure levels and heart rates. Followed by the testing, the pulse waveforms generated by the prototype are compared with the representative, in vivo, pulse waveform. The radial Augmentation Index analysis results show that the percent error between the simulator data and human pulse profiles is sufficiently small, indicating that the first two peak pressures agree well. Moreover, the phase analysis results show that the phase delay errors between the pulse waveforms of the prototype and the representative waveform are adequately small, confirming that the prototype simulator is capable of simulating realistic human pulse waveforms. This study demonstrated that a very accurate radial pressure waveform can be reproduced using the cam-based simulator. It can be concluded that the same testing and design methods can be used to generate pulse waveforms for other age groups or any target pulse waveforms. Such a simulator can make a contribution to the research efforts, such as development of wearable pressure sensors, standardization of pulse diagnosis in oriental medicine, and training medical professionals for pulse diagnosis techniques.

17 August 2022 in Advanced Science
Verified
Journal Article
Open access
GHGui Won Hwang
Gui Won Hwang
HLHeon Joon Lee
Heon Joon Lee
DKDa Wan Kim
Da Wan Kim
TYTae-Heon Yang
Tae-Heon Yang
CPChanghyun Pang
Changhyun Pang
Bioinspired soft devices, which possess high adaptability to targeted objects, provide promising solutions for a variety of industrial and medical applications. However, achieving stable and switchable attachment to objects with curved, rough, and irregular surfaces remains difficult, particularly in dry and underwater environments. Here, a highly adaptive soft microstructured switchable adhesion device is presented, which is inspired by the geometric and material characteristics of the tiny denticles on the surface of an octopus sucker. The contact interface of the artificial octopus sucker (AOS) is imprinted with soft, microscale denticles that interact adaptably with highly rough or curved surfaces. Robust and controllable attachment of the AOS with soft microdenticles (AOS‐sm) to dry and wet surfaces with diverse morphologies is achieved, allowing conformal attachment on curved and soft objects with high roughness. In addition, AOS‐sms assembled with an octopus‐arm‐inspired soft actuator demonstrate reliable grasping and the transport of complex polyhedrons, rough objects, and soft, delicate, slippery biological samples.

17 August 2020 in IEEE Transactions on Haptics
Verified
Journal Article
Closed access
TYTae-Heon Yang
Tae-Heon Yang
HSHyungki Son
Hyungki Son
SBSangkyu Byeon
Sangkyu Byeon
HGHyunjae Gil
Hyunjae Gil
IHInwook Hwang
Inwook Hwang
JKJin Ryong Kim
Jin Ryong Kim
In this article, present RealWalk, a pair of haptic shoes for HMD-based VR, designed to create realistic sensations of ground surface deformation, and texture using Magnetorheological fluid (MR fluid). RealWalk offers a novel interaction scheme through the physical interaction between the shoes, and the ground surfaces while walking in VR. Each shoe consists of two MR fluid actuators, an insole pressure sensor, and a foot position tracker. The MR fluid actuators are designed in the form of multi-stacked disc structure with a long flow path to maximize the flow resistance. With changing the magnetic field intensity in MR fluid actuators based on the ground material in the virtual scene, the viscosity of MR fluid is changed accordingly. When a user steps on the ground with the shoes, the two MR fluid actuators are pressed down, creating a variety of ground material deformation such as snow, mud, and dry sand. We built an interactive VR application, and compared RealWalk with vibrotactile-based haptic shoes in four different VR scenes: grass, sand, mud, and snow. We report that, compared to vibrotactile-haptic shoes, RealWalk provides higher ratings in all scenes for discrimination, realism, and satisfaction. We also report qualitative user feedback for their experiences.

11 February 2019 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
TYTae-Heon Yang
Tae-Heon Yang
Jaeuk KimJaeuk Kim
Jaeuk Kim
YKYoung-Min Kim
Young-Min Kim
JKJeong-Hoi Koo
Jeong-Hoi Koo
SWSamYong Woo
SamYong Woo
To meet the need for “standard” testing system for wearable blood pressure sensors, this study intends to develop a new radial pulsation simulator that can generate age-dependent reference radial artery pressure waveforms reflecting the physiological characteristics of human cardiovascular system. To closely duplicate a human cardiovascular system, the proposed simulator consists of a left ventricle simulation module, an aorta simulation module, a peripheral resistance simulation module, and a positive/negative pressure control reservoir module. Simulating physiologies of blood pressure, the compliance chamber in the simulator can control arterial stiffness to produce age-dependent pressure waveforms. The augmentation index was used to assess the pressure waveforms generated by the simulator. The test results show that the simulator can generate and control radial pressure waveforms similar to human pulse signals consisting of early systolic pressure, late systolic pressure, and dicrotic notch. Furthermore, the simulator’s left ventricular pressure-volume loop results demonstrate that the simulator exhibits mechanical characteristics of the human cardiovascular system. The proposed device can be effectively used as a “standard” radial artery pressure simulator to calibrate the wearable sensor’s measurement characteristics and to develop more advanced sensors. The simulator is intended to serve as a platform for the development, performance verification, and calibration of wearable blood pressure sensors. It will contribute to the advancement of the wearable blood pressure sensor technology, which enables real-time monitoring of users’ radial artery pressure waveforms and eventually predicting cardiovascular diseases.

6 August 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JJJae-Hak Jeong
Jae-Hak Jeong
YKYoung-Min Kim
Young-Min Kim
BLBomi Lee
Bomi Lee
JHJunki Hong
Junki Hong
Jaeuk KimJaeuk Kim
Jaeuk Kim
Yong-Hwa ParkYong-Hwa Park
Yong-Hwa Park
This study presents a design and evaluation of a mock circulatory platform, which can reproduce blood pressure and its waveforms to provide palpation experience based on the human cardiovascular physiology. To reproduce the human cardiovascular behavior, especially the blood pressure, the proposed platform includes three major modules: heart, artery and reservoir modules. The heart module reproduces source pressure exerted on the whole system with a controlled time-profile. The artery module consists of a resistance valve to adjust the open area of the vessel and a compliance chamber adjusting the wall stiffness of the ascending aorta. The designed platform was cross validated by comparing the theory with a lumped model, i.e., the windkessel model, the measurements from the mock circulatory platform and the real human body data. As a result, the ventricular and aortic pressure waveforms measured from the designed platform were well matched with those of the actual human body. Parametric studies regarding peripheral resistance and aortic compliance were done for the detailed correlation analysis between human cardiovascular physiology and blood pressure. Since the proposed platform is based on the actual cardiovascular physiology, adjusting the structural parameters of the components can reproduce realistic blood pressure waveforms in a controllable manner. This platform is applicable to blood pressure measurement sensor calibration, palpation training, and haptic feedback.

6 April 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
AMAlex Mazursky
Alex Mazursky
JKJeong-Hoi Koo
Jeong-Hoi Koo
TYTae-Heon Yang
Tae-Heon Yang
Robust haptic devices that can convey the entire spectrum of human touch perception are necessary to afford realistic haptic experiences. For vivid and immersive interaction, a combination of both tactile and kinesthetic information must be presented to users. While vibrotactile feedback has become ubiquitous in today’s handheld devices, traditional kinesthetic actuators present significant challenges to miniaturization. Moreover, only limited success has been achieved in developing haptic actuators capable of conveying both tactile and kinesthetic sensations for small consumer electronics. Therefore, this study presents a compact actuator based on electrorheological (ER) fluid for generating a wide range of concurrent kinesthetic and tactile feedback. The design focus for the proposed actuator is to activate multiple operating modes of ER fluid to maximize the force generated by the actuator within a given small size constraint. To this end, the design incorporated two ground electrodes (a stationary ring electrode and a movable electrode attached to a spring element) for tuning the fluid’s yield stress in both flow and squeeze modes. After fabricating a prototype actuator, testing was performed with a dynamic mechanical analyzer (DMA) and an accelerometer to evaluate its ability to produce a wide range of kinesthetic feedback, as well as distinct vibrotactile feedback up to the limit of human perception. The results of kinesthetic testing indicate that the actuator can generate large forces (6.2 N maximum at 4 kV) at rates greater than the just-noticeable difference, indicating that the actuator can convey a wide range of kinesthetic sensations. Tactile evaluation using DMA and the processed acceleration response demonstrated that the actuator can generate both low and high frequency (up to 300 Hz) vibrotactile sensations at perceivably high intensity.