Zhongjun Liu

Prof. Zhongjun Liu

Peking University Third Hospital

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Bioactive Materials
Verified
Journal Article
Open access
TZTeng Zhang
Teng Zhang
QWQingguang Wei
Qingguang Wei
HZHua Zhou
Hua Zhou
ZJZehao Jing
Zehao Jing
XLXiaoguang Liu
Xiaoguang Liu
ZLZhongjun Liu
Zhongjun Liu
Bone defect repairs are based on bone graft fusion or replacement. Current large bone defect treatments are inadequate and lack of reliable technology. Therefore, we aimed to investigate a simple technique using three-dimensional (3D)-printed individualized porous implants without any bone grafts, osteoinductive agents, or surface biofunctionalization to treat large bone defects, and systematically study its long-term therapeutic effects and osseointegration characteristics. Twenty-six patients with large bone defects caused by tumor, infection, or trauma received treatment with individualized porous implants; among them, three typical cases underwent a detailed study. Additionally, a large segmental femur defect sheep model was used to study the osseointegration characteristics. Immediate and long-term biomechanical stability was achieved, and the animal study revealed that the bone grew into the pores with gradual remodeling, resulting in a long-term mechanically stable implant-bone complex. Advantages of 3D-printed microporous implants for the repair of bone defects included 1) that the stabilization devices were immediately designed and constructed to achieve early postoperative mobility, and 2) that osseointegration between the host bone and implants was achieved without bone grafting. Our osseointegration method, in which the “implant-bone” interface fusion concept was used instead of “bone-bone” fusion, subverts the traditional idea of osseointegration.

30 April 2020 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
TZTeng Zhang
Teng Zhang
QWQingguang Wei
Qingguang Wei
HZHua Zhou
Hua Zhou
WZWenhao Zhou
Wenhao Zhou
DFDaoyang Fan
Daoyang Fan
ZLZhongjun Liu
Zhongjun Liu
Elimination of infection and enhancement of osteogenesis by orthopaedic implants are two critical factors in the treatment of complex bone infections. A prolonged and expensive procedure requiring two surgical steps and a 6–8-week period of joint immobilisation is utilised as a primary treatment for revision arthroplasty of an infected prosthesis, greatly affecting long-term patient care for the ageing population. Here, we evaluated the effects of vancomycin-loaded in micro-arc oxidised (MAO) three-dimensional (3D) printed porous Ti6Al4V scaffolds on osteogenesis. This system showed a high loading capacity and sustained vancomycin release kinetics, as demonstrated using high-performance liquid chromatography. In vivo, 0.1 mL of 108 colony forming units (CFU) methicillin-resistant Staphylococcus aureus was injected into the tibias of rabbits to induce severe osteomyelitis. Physical, haematological, radiographic, microbiological, and histopathological analyses were performed to evaluate the effects of treatment. Rabbits with vancomycin-loaded in MAO scaffolds showed the inhibition of bone infection and enhancement of osteogenesis, resulting in better outcomes than in the other groups. Overall, these findings demonstrated the potential of this 3D printed porous Ti6Al4V, with good osteogenesis and sustained vancomycin release properties, for application in the treatment of complex bone infections.

25 June 2021 in Bioactive Materials
Verified
Journal Article
Open access
CYChuan Yin
Chuan Yin
TZTeng Zhang
Teng Zhang
QWQingguang Wei
Qingguang Wei
HCHong Cai
Hong Cai
YCYan Cheng
Yan Cheng
ZLZhongjun Liu
Zhongjun Liu
Three-dimensional (3D)-printed porous Ti6Al4V implants play an important role in the reconstruction of bone defects. However, its osseointegration capacity needs to be further improved, and related methods are inadequate, especially lacking customized surface treatment technology. Consequently, we aimed to design an omnidirectional radiator based on ultraviolet (UV) photofunctionalization for the surface treatment of 3D-printed porous Ti6Al4V implants, and studied its osseointegration promotion effects in vitro and in vivo, while elucidating related mechanisms. Following UV treatment, the porous Ti6Al4V scaffolds exhibited significantly improved hydrophilicity, cytocompatibility, and alkaline phosphatase activity, while preserving their original mechanical properties. The increased osteointegration strength was further proven using a rabbit condyle defect model in vivo, in which UV treatment exhibited a high efficiency in the osteointegration enhancement of porous Ti6Al4V scaffolds by increasing bone ingrowth (BI), the bone-implant contact ratio (BICR), and the mineralized/osteoid bone ratio. The advantages of UV treatment for 3D-printed porous Ti6Al4V implants using the omnidirectional radiator in the study were as follows: 1) it can significantly improve the osseointegration capacity of porous titanium implants despite the blocking out of UV rays by the porous structure; 2) it can evenly treat the surface of porous implants while preserving their original topography or other morphological features; and 3) it is an easy-to-operate low-cost process, making it worthy of wide clinical application.

16 December 2019 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
TZTeng Zhang
Teng Zhang
QWQingguang Wei
Qingguang Wei
DFDaoyang Fan
Daoyang Fan
XLXiaoguang Liu
Xiaoguang Liu
WLWeishi Li
Weishi Li
ZLZhongjun Liu
Zhongjun Liu
3D-printed porous implant can be easily inserted using a rhBMP-2 tablet during surgery for an ideal rhBMP-2 release and osseointegration.

29 December 2021 in Proteomics – Clinical Applications
Verified
Journal Article
Closed access
PDF file
TZTengjiao Zhu
Tengjiao Zhu
QTQizhao Tan
Qizhao Tan
XXXing Xin
Xing Xin
FLFeng Li
Feng Li
KZKe Zhang
Ke Zhang
YTYun Tian
Yun Tian

24 March 2021 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
ZYZhenguo Yu
Zhenguo Yu
HCHong Cai
Hong Cai
BYBin Yang
Bin Yang
JYJie Yao
Jie Yao
KZKe Zhang
Ke Zhang
ZLZhongjun Liu
Zhongjun Liu
Background: To manage patellofemoral joint disorders, a complete understanding of the in vivo patellofemoral kinematics is critical. However, as one of the parameters of joint kinematics, the location and orientation of the patellofemoral finite helical axis (FHA) remains unclear. The purpose of this study is to quantify the location and orientation of the patellar FHA, both in vivo and non-invasively at various flexion angles, and evaluate the relationship of the FHA and the trans-epicondylar axis (TEA). Methods: The magnetic resonance (MR) images of 18 unilateral knees were collected at full extension, 30°, 60°, 90°, and maximum angle of knee flexion. Three-dimensional models of the knee joint at different flexion angles were created using the MR images, and then used to calculate the patellar tracking and FHA with a spline interpolation algorithm. By using a coordinate system based on the TEA, the FHA tracking was quantified. Six parameters concerning the location and orientation of the patellar FHA were analysed. Results: The average patellar FHA drew an L-shaped tracking on the midsagittal plane moving from the posteroinferior to the anterosuperior side of the TEA with knee flexion. Before 90° flexion, the patellar rotational radius decreased slightly, with an average value of 5.65 ± 1.09 cm. During 20° to 90° knee flexion, the average angle between the patellar FHA and the TEA was approximately 10° and that between the FHA and the coronal plane was maintained at about 0°, while that between the FHA and the level plane fluctuated between − 10° and 10°. Conclusions: This study quantitatively reported the continuous location and direction of the patellar FHA during knee flexion. The patellar FHA was close to but not coincident with the femoral TEA both in location and orientation, and the patellar rotational radius decreased slightly with knee flexion. These findings could provide a clear direction for further studies on the difference in patellofemoral FHA among various types of patellofemoral disorders, and provide a foundation for the application of FHA in surgical evaluation, preoperative planning and prosthesis design, thereby assisting in the diagnosis and treatment of patellofemoral disorders.