Sebastián Eugenio Godoy

Dr. Sebastián Eugenio Godoy

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
BCBraulio Contreras-Trigo
Braulio Contreras-Trigo
VDVictor Diaz
Victor Diaz
EGEnrique Guzmán-Gutiérrez
Enrique Guzmán-Gutiérrez
ISIgnacio Sanhueza
Ignacio Sanhueza
PCPablo Coelho
Pablo Coelho
Patricio OyarzunPatricio Oyarzun
Patricio Oyarzun
Gold nanoparticles (AuNPs) are currently under intense investigation for biomedical and biotechnology applications, thanks to their ease in preparation, stability, biocompatibility, multiple surface functionalities, and size-dependent optical properties. The most commonly used method for AuNP synthesis in aqueous solution is the reduction of tetrachloroauric acid (HAuCl4) with trisodium citrate. We have observed variations in the pH and in the concentration of the gold colloidal suspension synthesized under standard conditions, verifying a reduction in the reaction yield by around 46% from pH 5.3 (2.4 nM) to pH 4.7 (1.29 nM). Citrate-capped AuNPs were characterized by UV-visible spectroscopy, TEM, EDS, and zeta-potential measurements, revealing a linear correlation between pH and the concentration of the generated AuNPs. This result can be attributed to the adverse effect of protons both on citrate oxidation and on citrate adsorption onto the gold surface, which is required to form the stabilization layer. Overall, this study provides insight into the effect of the pH over the synthesis performance of the method, which would be of particular interest from the point of view of large-scale manufacturing processes.

22 March 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
SGSebastián Eugenio Godoy
Sebastián Eugenio Godoy
MHMajeed M. Hayat
Majeed M. Hayat
DRDavid A. Ramirez
David A. Ramirez
SMStephen A. Myers
Stephen A. Myers
RPR. Steven Padilla
R. Steven Padilla
SKSanjay Krishna
Sanjay Krishna
Skin cancer is the most common cancer in the United States with over 3.5M annual cases. Presently, visual inspection by a dermatologist has good sensitivity (> 90%) but poor specificity (< 10%), especially for melanoma, which leads to a high number of unnecessary biopsies. Here we use dynamic thermal imaging (DTI) to demonstrate a rapid, accurate and non-invasive imaging system for detection of skin cancer. In DTI, the lesion is cooled down and the thermal recovery is recorded using infrared imaging. The thermal recovery curves of the suspected lesions are then utilized in the context of continuous-time detection theory in order to define an optimal statistical decision rule such that the sensitivity of the algorithm is guaranteed to be at a maximum for every prescribed false-alarm probability. The proposed methodology was tested in a pilot study including 140 human subjects demonstrating a sensitivity in excess of 99% for a prescribed specificity in excess of 99% for detection of skin cancer. To the best of our knowledge, this is the highest reported accuracy for any non-invasive skin cancer diagnosis method.

1 May 2015 in Infrared Physics & Technology
Verified
Journal Article
Closed access
SGSebastián Eugenio Godoy
Sebastián Eugenio Godoy
DRDavid A. Ramirez
David A. Ramirez
SMStephen A. Myers
Stephen A. Myers
GWGreg von Winckel
Greg von Winckel
SKSanjay Krishna
Sanjay Krishna
PSPradeep Sen
Pradeep Sen

14 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PGPablo Gutierrez
Pablo Gutierrez
SGSebastián Eugenio Godoy
Sebastián Eugenio Godoy
STSERGIO TORRES
SERGIO TORRES
Patricio OyarzunPatricio Oyarzun
Patricio Oyarzun
ISIgnacio Sanhueza
Ignacio Sanhueza
PCPablo Coelho
Pablo Coelho
In this article we present the development of a biosensor system that integrates nanotechnology, optomechanics and a spectral detection algorithm for sensitive quantification of antibiotic residues in raw milk of cow. Firstly, nanobiosensors were designed and synthesized by chemically bonding gold nanoparticles (AuNPs) with aptamer bioreceptors highly selective for four widely used antibiotics in the field of veterinary medicine, namely, Kanamycin, Ampicillin, Oxytetracycline and Sulfadimethoxine. When molecules of the antibiotics are present in the milk sample, the interaction with the aptamers induces random AuNP aggregation. This phenomenon modifies the initial absorption spectrum of the milk sample without antibiotics, producing spectral features that indicate both the presence of antibiotics and, to some extent, its concentration. Secondly, we designed and constructed an electro-opto-mechanic device that performs automatic high-resolution spectral data acquisition in a wavelength range of 400 to 800 nm. Thirdly, the acquired spectra were processed by a machine-learning algorithm that is embedded into the acquisition hardware to determine the presence and concentration ranges of the antibiotics. Our approach outperformed state-of-the-art standardized techniques (based on the 520/620 nm ratio) for antibiotic detection, both in speed and in sensitivity.

4 August 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
ZTZ.-B. Tian
Z.-B. Tian
SGSebastián Eugenio Godoy
Sebastián Eugenio Godoy
HKH. S. Kim
H. S. Kim
TST. Schuler-Sandy
T. Schuler-Sandy
JMJ. A. Montoya
J. A. Montoya
SKSanjay Krishna
Sanjay Krishna
In this paper, we report the initial demonstration of mid-infrared interband cascade (IC) photodetector focal plane arrays with multiple-stage/junction design. The merits of IC photodetectors include low noise and efficient photocarrier extraction, even for zero-bias operation. By adopting enhanced electron barrier design and a total absorber thickness of 0.7 μm, the 5-stage IC detectors show very low dark current (1.10 × 10−7 A/cm2 at −5 mV and 150 K). Even with un-optimized fabrication and standard commercial (mis-matched) read-out circuit technology, infrared images are obtained by the 320 × 256 IC focal plane array up to 180 K with f/2.3 optics. The minimum noise equivalent temperature difference of 28 mK is obtained at 120 K. These initial results indicate great potential of IC photodetectors, particularly for high operating temperature applications.

8 October 2008 in Applied Optics
Verified
Journal Article
Closed access
PDF file
SGSebastián Eugenio Godoy
Sebastián Eugenio Godoy
JPJorge E. Pezoa
Jorge E. Pezoa
STSergio N. Torres
Sergio N. Torres
The spatial fixed-pattern noise (FPN) inherently generated in infrared (IR) imaging systems compromises severely the quality of the acquired imagery, even making such images inappropriate for some applications. The FPN refers to the inability of the photodetectors in the focal-plane array to render a uniform output image when a uniform-intensity scene is being imaged. We present a noise-cancellation-based algorithm that compensates for the additive component of the FPN. The proposed method relies on the assumption that a source of noise correlated to the additive FPN is available to the IR camera. An important feature of the algorithm is that all the calculations are reduced to a simple equation, which allows for the bias compensation of the raw imagery. The algorithm performance is tested using real IR image sequences and is compared to some classical methodologies.