Emilio Lorenzani

Prof. Emilio Lorenzani

Department of Sciences and Methods for Engineering, University of Modena and Reggio Emilia, 42122 Reggio Emilia, Italy

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Giampaolo ButicchiGiampaolo Buticchi
Giampaolo Buticchi
DBDavide Barater
Davide Barater
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
Carlo ConcariCarlo Concari
Carlo Concari
GFGiovanni Franceschini
Giovanni Franceschini
This paper presents a single-phase transformerless grid-connected photovoltaic converter based on two cascaded full bridges with different dc-link voltages. The converter can synthesize up to nine voltage levels with a single dc bus, since one of the full bridges is supplied by a flying capacitor. The multilevel output reduces harmonic distortion and electromagnetic interference. A suitable switching strategy is employed to regulate the flying-capacitor voltage, improve the efficiency (most devices switch at the grid frequency), and minimize the common-mode leakage current with the help of a novel dedicated circuit (transient circuit). Simulations and experiments confirm the feasibility and good performance of the proposed converter.

3 April 2012 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Giampaolo ButicchiGiampaolo Buticchi
Giampaolo Buticchi
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
GFGiovanni Franceschini
Giovanni Franceschini
In low-power renewable systems, a single-phase grid-connected converter is usually adopted. This paper deals with a novel five-level converter topology that follows this trend. A review of the state of the art of the five-level topologies and a theoretical power loss comparison with the proposed solution is realized. The proposed converter architecture is based on a full-bridge topology with two additional power switches and two diodes connected to the midpoint of the dc link. Since the two added levels are obtained by the discharge of the two capacitors of the dc link, the balancing of the midpoint voltage is obtained with a specific pulse width modulation (PWM) strategy. Simulation and experimental results show the effectiveness of the proposed solution.

23 December 2019 in IEEE Industrial Electronics Magazine
Verified
Journal Article
Open access
VMVincenzo Madonna
Vincenzo Madonna
Giovanni MigliazzaGiovanni Migliazza
Giovanni Migliazza
PGPaolo Giangrande
Paolo Giangrande
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
Giampaolo ButicchiGiampaolo Buticchi
Giampaolo Buticchi
Michael GaleaMichael Galea
Michael Galea
It is well known and widely accepted that the voltage source inverter (VSI) now dominates the world of electrical drives. Its success is probably due to its simplicity, high efficiency, and the widespread availability of VSs. This popularity has, in turn, influenced the evolution of the semiconductor industry, which has focused in recent years on devices tailored for VSIs. Thus, products such as depletion devices (normally off) and those without reverse voltage blocking have been widely marketed and used.

3 April 2012 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
Giampaolo ButicchiGiampaolo Buticchi
Giampaolo Buticchi
DBDavide Barater
Davide Barater
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
GFGiovanni Franceschini
Giovanni Franceschini
The design of a photovoltaic (PV) grid-connected converter usually comprehends a galvanic isolation between the grid and the photovoltaic panels. Recently, in low power systems, the galvanic isolation has been removed with the aim to increase efficiency and reduce the cost of the converter. Due to the presence of a parasitic capacitance between the photovoltaic cells and the metal frame of the PV panel, usually connected to earth, a high value of common mode current (i.e., ground leakage current) can arise. In order to limit the ground leakage current (which deteriorates the power quality and generates EMI), new converter topologies have been proposed. Their effectiveness is based on the symmetrical (ideal) commutations of the power switches and some of them adopt a further voltage level derived from a capacitive divider of the DC bus voltage. Unfortunately, in actual implementations, asymmetrical power switches transients and variations of this added voltage lead to higher ground leakage current with respect to the ideal case. After a review of the state of the art this paper investigates these two issues and presents a particular solution (based on digital control and PWM strategy) that, in conjunction with a compensation strategy of power switches actual commutations, guarantees low ground leakage current regardless the parameters tolerance of the power circuit. Simulation and experimental results confirm the effectiveness of the proposed solution.

1 October 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DBDavide Barater
Davide Barater
Giampaolo ButicchiGiampaolo Buticchi
Giampaolo Buticchi
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
Carlo ConcariCarlo Concari
Carlo Concari
This paper proposes a solution for reducing the ground leakage current in transformerless single-phase grid-connected photovoltaic converters. This is obtained with the introduction of an active common-mode filter able to compensate for variations of the output common-mode voltage of the power converter. The active common-mode filter is applied to a widespread and efficient full-bridge driven by a three-level pulse width modulation, allowing the power converter to operate with low ground leakage current and with an arbitrary power factor. After showing the desired voltage waveform for common-mode voltage compensation, this paper presents the design guidelines for the needed additional magnetic component together with the power loss considerations for all the devices added for the proposed solution. Experimental results show the performance of the proposed solution in terms of ground leakage current reduction, effectiveness of dead-time compensation, total harmonic distortion of the injected grid current, and power losses.

15 May 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
Claudio BianchiniClaudio Bianchini
Claudio Bianchini
Fabio ImmovilliFabio Immovilli
Fabio Immovilli
Emilio LorenzaniEmilio Lorenzani
Emilio Lorenzani
Alberto BelliniAlberto Bellini
Alberto Bellini
MDMatteo Davoli
Matteo Davoli
Internal permanent-magnet synchronous machines are spreading in industrial production. They feature high torque density and extended speed range that are key issues in many fields of applications, however their cogging torque is typically quite high. Many methods and design guidelines for cogging torque reduction exist in literature and this paper compares them. For this purpose, the different design guidelines are applied to a common reference machine in order to assess their effectiveness. Computer finite element analysis (FEA) are carried out for each case in order to compare the cogging torque reduction capability of the different techniques. The side effects of these techniques, such as back-EMF and rated torque profile distortions, will be taken into account. The paper contribution is to compare the various cogging torque reduction techniques and magnetic geometries on a common reference machine to identify the most effective ones.