Enrique Mancha-Sánchez

Mr. Enrique Mancha-Sánchez

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2020 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
JGJ. Carlos Gómez-Blanco
J. Carlos Gómez-Blanco
ENEsther López Nieto
Esther López Nieto
JCJavier G. Casado
Javier G. Casado
AMAntonio Macías-García
Antonio Macías-García
J. Blas PagadorJ. Blas Pagador
J. Blas Pagador
Nowadays, bioprinting is rapidly evolving and hydrogels are a key component for its success. In this sense, synthesis of hydrogels, as well as bioprinting process, and cross-linking of bioinks represent different challenges for the scientific community. A set of unified criteria and a common framework are missing, so multidisciplinary research teams might not efficiently share the advances and limitations of bioprinting. Although multiple combinations of materials and proportions have been used for several applications, it is still unclear the relationship between good printability of hydrogels and better medical/clinical behavior of bioprinted structures. For this reason, a PRISMA methodology was conducted in this review. Thus, 1,774 papers were retrieved from PUBMED, WOS, and SCOPUS databases. After selection, 118 papers were analyzed to extract information about materials, hydrogel synthesis, bioprinting process, and tests performed on bioprinted structures. The aim of this systematic review is to analyze materials used and their influence on the bioprinting parameters that ultimately generate tridimensional structures. Furthermore, a comparison of mechanical and cellular behavior of those bioprinted structures is presented. Finally, some conclusions and recommendations are exposed to improve reproducibility and facilitate a fair comparison of results.

12 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
MPManuel Matamoros Pacheco
Manuel Matamoros Pacheco
JBJuan Carlos Gómez Blanco
Juan Carlos Gómez Blanco
ÁSÁlvaro J. Sánchez
Álvaro J. Sánchez
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
J. Blas PagadorJ. Blas Pagador
J. Blas Pagador
Bioprinting is a complex process, highly dependent on bioink properties (materials and cells) and environmental conditions (mainly temperature, humidity and CO2 concentration) during the bioprinting process. To guarantee proper cellular viability and an accurate geometry, it is mandatory to control all these factors. Despite internal factors, such as printing pressures, temperatures or speeds, being well-controlled in actual bioprinters, there is a lack in the controlling of external parameters, such as room temperature or humidity. In this sense, the objective of this work is to control the temperature and humidity of a new, atmospheric enclosure system for bioprinting. The control has been carried out with a decoupled proportional integral derivative (PID) controller that was designed, simulated and experimentally tested in order to ensure the proper operation of all its components. Finally, the PID controller can stabilize the atmospheric enclosure system temperature in 311 s and the humidity in 65 s, with an average error of 1.89% and 1.30%, respectively. In this sense, the proposed atmospheric enclosure system can reach and maintain the proper temperature and humidity values during post-printing and provide a pre-incubation environment that promotes stability, integrity and cell viability of the 3D bioprinted structures.

17 July 2020 in Processes
Verified
Journal Article
Open access
PDF file
JBJuan Carlos Gómez Blanco
Juan Carlos Gómez Blanco
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
MPManuel Matamoros Pacheco
Manuel Matamoros Pacheco
ADAntonio Díaz-Parralejo
Antonio Díaz-Parralejo
J. Blas PagadorJ. Blas Pagador
J. Blas Pagador
Bioinks are usually cell-laden hydrogels widely studied in bioprinting performing experimental tests to tune their rheological properties, thus increasing research time and development costs. Computational Fluids Dynamics (CFD) is a powerful tool that can minimize iterations and costs simulating the material behavior using parametric changes in rheological properties under testing. Additionally, most bioinks have specific functionalities and their properties might widely change with temperature. Therefore, commercial bioinks are an excellent way to standardize bioprinting process, but they are not analyzed in detail. Therefore, the objective of this work is to study how three temperatures of the Cellink Bioink influence shear stress pressure and velocity through computational simulation. A comparison of three conical nozzles (20, 22, and 25G) for each temperature has been performed. The results show that shear stress, pressure, and velocity vary in negligible ranges for all combinations. Although these ranges are small and define a good thermo-responsive bioink, they do not generate a filament on the air and make drops during extrusion. In conclusion, this bioink provides a very stable behavior with low shear stress, but other bioprinting parameters must be set up to get a stable filament width.

12 November 2017
Verified
Book Chapter
Closed access
PDF file
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
JTJosé Emilio Traver
José Emilio Traver
ITInés Tejado
Inés Tejado
JPJavier Prieto
Javier Prieto
Blas M VinagreBlas M Vinagre
Blas M Vinagre
Vicente Feliu-BatlleVicente Feliu-Batlle
Vicente Feliu-Batlle

27 May 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
ASAndrés J. Serrano-Balbontín
Andrés J. Serrano-Balbontín
Inés TejadoInés Tejado
Inés Tejado
Blas M VinagreBlas M Vinagre
Blas M Vinagre
This study presents a novel capillary microgripper for manipulating micrometer-sized objects directly within aqueous environments. The system features dynamic, vision-based feedback control of a non-volatile silicone oil droplet volume, enabling precise adjustment of the capillary bridge force for the adaptable capture of varying object sizes. This approach ensures extended working time and stable operation in water, mitigating the issues associated with evaporation common in other systems. COMSOL Multiphysics simulations analyzed capillary bridge formation. Experimental validation demonstrated successful different object shapes and sizes capture in an aqueous environment and further explored active release strategies necessary due to the non-volatile fluid, confirming the system potential for robust underwater micromanipulation.

1 September 2025 in Jornadas de Automática
Verified
Journal Article
Open access
PDF file
ASAndrés J. Serrano-Balbontín
Andrés J. Serrano-Balbontín
FNFrancisco Javier Nevado-Moya
Francisco Javier Nevado-Moya
Inés TejadoInés Tejado
Inés Tejado
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
Blas M VinagreBlas M Vinagre
Blas M Vinagre
El campo de la ingeniería biomédica evoluciona constantemente a medida que los investigadores exploran nuevos materiales y tecnologías para mejorar los resultados de los pacientes. Los catéteres se utilizan habitualmente tanto en cirugía mínimamente invasiva como en diagnóstico, y la mayoría de ellos se guían externa y manualmente. Este artículo presenta una prueba de concepto de nuestros avances actuales en catéteres robóticos con navegación autónoma. El catéter consta básicamente de un actuador hidráulico blando con una nanocámara en su extremo distal, que funciona como mecanismo de dirección (orientación de la punta), un mecanismo de conducción, para proporcionar desplazamiento axial (empuje o tracción) y rotación sobre su eje principal al catéter, y una unidad de control, que gestiona el funcionamiento de todo el sistema. El catéter navega gracias a un algoritmo que combina el seguimiento de la pared por contacto intermitente y el procesamiento de imágenes en tiempo real.