Alfonso C. Marcos

Dr. Alfonso C. Marcos

Graphic Expression, University of Extremadura, Badajoz, Extremadura, Spain
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
DPDavid Picado-Tejero
David Picado-Tejero
Laura Mendoza CerezoLaura Mendoza Cerezo
Laura Mendoza Cerezo
JRJesús Manuel Rodríguez Rego
Jesús Manuel Rodríguez Rego
JCJuan Pablo Carrasco-Amador
Juan Pablo Carrasco-Amador
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
3D bioprinting has emerged as a key tool in tissue engineering by facilitating the creation of customized scaffolds with properties tailored to specific needs. Among the design parameters, porosity stands out as a determining factor, as it directly influences critical mechanical and biological properties such as nutrient diffusion, cell adhesion and structural integrity. This review comprehensively analyses the state of the art in scaffold design, emphasizing how porosity-related parameters such as pore size, geometry, distribution and interconnectivity affect cellular behavior and mechanical performance. It also addresses advances in manufacturing methods, such as additive manufacturing and computer-aided design (CAD), which allow the development of scaffolds with hierarchical structures and controlled porosity. In addition, the use of computational modelling, in particular finite element analysis (FEA), as an essential predictive tool to optimize the design of scaffolds under physiological conditions is highlighted. This narrative review analyzed 112 core articles retrieved primarily from Scopus (2014–2025) to provide a comprehensive and up-to-date synthesis. Despite recent progress, significant challenges persist, including the lack of standardized methodologies for characterizing and comparing porosity parameters across different studies. This review identifies these gaps and suggests future research directions, such as the development of unified characterization and classification systems and the enhancement of nanoscale resolution in bioprinting technologies. By integrating structural design with biological functionality, this review underscores the transformative potential of porosity research applied to 3D bioprinting, positioning it as a key strategy to meet current clinical needs in tissue engineering.

13 August 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
José Ignacio Fernández-VigoJosé Ignacio Fernández-Vigo
José Ignacio Fernández-Vigo
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
RARafael Agujetas
Rafael Agujetas
JMJosé María Montanero
José María Montanero
IGInes Sanchez Guillen
Ines Sanchez Guillen
AMAna Macarro-Merino
Ana Macarro-Merino
To compare aqueous humour (AH) dynamics in the presence of a precrystalline (Implantable Collamer Lens®; ICL) or iris-fixed (Artiflex®) phakic intraocular lens (PIOL). By computational fluid dynamics simulation, AH flow was modelled through a peripheral iridotomy (PI) or central lens hole (both 360 μm) in the presence of an Artiflex or ICL lens, respectively. The impacts of AH flow were then determined in terms of wall shear stress (WSS) produced on the endothelium or crystalline lens. Effects were also modelled for different scenarios of pupil diameter (PD 3.5 or 5.5 mm), ICL vault (100, 350, 800 μm) and number of Artiflex iridotomies (1 or 2) and location (12 or 6 o’clock). For a PD of 3.5 mm, AH volumes flowing from the posterior to the anterior chamber were 37.6% of total flow through the lens hole (ICL) and 84.2% through PI (Artiflex). For an enlarged PD (5.5 mm), corresponding values were 10.3% and 81.9% respectively, so PI constitutes a very efficient way of evacuating AH. Central endothelial WSS in Pa was lower for the large vault ICL and the Artiflex (1−03 and 1.1−03 respectively) compared to the PIOL-free eye (1.6−03). Crystalline lens WSS was highest for the lowest vault ICL (1−04). AH flow varied according to the presence of a precrystalline or iris-fixed intraocular lens. Endothelial WSS was lower for an implanted ICL with large vault and Artiflex than in the PIOL-free eye, while highest crystalline WSS was recorded for the lowest vault ICL.

15 August 2011 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
RBR Barrio
R Barrio
JFJ Fernández
J Fernández
EBE Blanco
E Blanco
JPJ Parrondo
J Parrondo
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
Vaneless centrifugal pumps are reversible turbomachines that can operate also as centripetal turbines in low and very low-head power plants. However, the general performance in reverse mode is difficult to predict since the internal flow patterns are different from pump mode and the performance characteristics are not usually provided by manufacturers. This article presents numerical and experimental investigations on the operation of a reverse-running pump–turbine. The numerical calculations were carried out by solving the full unsteady Reynolds-averaged Navier–Stokes equations with the commercial code Fluent for several flowrates between 20 per cent and 160 per cent of rated conditions and both modes of operation. A complementary series of experimental measurements were performed in a test rig in order to obtain the general characteristics of the machine in pump and turbine modes, with the purpose of validating the numerical predictions. Once validated, the numerical model was used to investigate the flow patterns at some significant locations by means of pressure and velocity contours, and also by vector maps. Additionally, the model allowed the estimation of the steady load on the impeller as a function of flowrate in both modes of operation. It was concluded that, while the radial load in reverse mode is three times smaller than in pump mode, the axial load can be up to 1.6 times larger.

12 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
MPManuel Matamoros Pacheco
Manuel Matamoros Pacheco
JBJuan Carlos Gómez Blanco
Juan Carlos Gómez Blanco
ÁSÁlvaro J. Sánchez
Álvaro J. Sánchez
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
J. Blas PagadorJ. Blas Pagador
J. Blas Pagador
Bioprinting is a complex process, highly dependent on bioink properties (materials and cells) and environmental conditions (mainly temperature, humidity and CO2 concentration) during the bioprinting process. To guarantee proper cellular viability and an accurate geometry, it is mandatory to control all these factors. Despite internal factors, such as printing pressures, temperatures or speeds, being well-controlled in actual bioprinters, there is a lack in the controlling of external parameters, such as room temperature or humidity. In this sense, the objective of this work is to control the temperature and humidity of a new, atmospheric enclosure system for bioprinting. The control has been carried out with a decoupled proportional integral derivative (PID) controller that was designed, simulated and experimentally tested in order to ensure the proper operation of all its components. Finally, the PID controller can stabilize the atmospheric enclosure system temperature in 311 s and the humidity in 65 s, with an average error of 1.89% and 1.30%, respectively. In this sense, the proposed atmospheric enclosure system can reach and maintain the proper temperature and humidity values during post-printing and provide a pre-incubation environment that promotes stability, integrity and cell viability of the 3D bioprinted structures.

10 January 2023 in International Journal of Bioprinting
Verified
Journal Article
Open access
PDF file
JRJesús Manuel Rodríguez Rego
Jesús Manuel Rodríguez Rego
LMLaura Mendoza-Cerezo
Laura Mendoza-Cerezo
AMAntonio Macías-García
Antonio Macías-García
JCJuan P. Carrasco-Amador
Juan P. Carrasco-Amador
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
Currently, the characterization techniques for hydrogels used in bioprinting are extensive, and they could provide data on the physical, chemical, and mechanical properties of hydrogels. While characterizing the hydrogels, the analysis of their printing properties is of great importance in the determination of their potential for bioprinting. The study of printing properties provides data on their capacity to reproduce biomimetic structures and maintain their integrity after the process, as it also relates them to the possible cell viability after the generation of the structures. Current hydrogel characterization techniques require expensive measuring instrument that is not readily available in many research groups. Therefore, it would be interesting to propose a methodology to characterize and compare the printability of different hydrogels in a fast, simple, reliable, and inexpensive way. The aim of this work is to propose a methodology for extrusion-based bioprinters that allows determining the printability of hydrogels that are going to be loaded with cells, by analyzing cell viability with the sessile drop method, molecular cohesion with the filament collapse test, adequate gelation with the quantitative evaluation of the gelation state, and printing precision with the printing grid test. The data obtained after performing this work allow the comparison of different hydrogels or different concentrations of the same hydrogel to determine which one has the most favorable properties to carry out bioprinting studies.

17 July 2020 in Processes
Verified
Journal Article
Open access
PDF file
JBJuan Carlos Gómez Blanco
Juan Carlos Gómez Blanco
EMEnrique Mancha-Sánchez
Enrique Mancha-Sánchez
Alfonso C. MarcosAlfonso C. Marcos
Alfonso C. Marcos
MPManuel Matamoros Pacheco
Manuel Matamoros Pacheco
ADAntonio Díaz-Parralejo
Antonio Díaz-Parralejo
J. Blas PagadorJ. Blas Pagador
J. Blas Pagador
Bioinks are usually cell-laden hydrogels widely studied in bioprinting performing experimental tests to tune their rheological properties, thus increasing research time and development costs. Computational Fluids Dynamics (CFD) is a powerful tool that can minimize iterations and costs simulating the material behavior using parametric changes in rheological properties under testing. Additionally, most bioinks have specific functionalities and their properties might widely change with temperature. Therefore, commercial bioinks are an excellent way to standardize bioprinting process, but they are not analyzed in detail. Therefore, the objective of this work is to study how three temperatures of the Cellink Bioink influence shear stress pressure and velocity through computational simulation. A comparison of three conical nozzles (20, 22, and 25G) for each temperature has been performed. The results show that shear stress, pressure, and velocity vary in negligible ranges for all combinations. Although these ranges are small and define a good thermo-responsive bioink, they do not generate a filament on the air and make drops during extrusion. In conclusion, this bioink provides a very stable behavior with low shear stress, but other bioprinting parameters must be set up to get a stable filament width.