We present herein the very first amperometric biosensor for the quantitative determination of glycine in diverse biological fluids. The biosensor is based on a novel quinoprotein that catalyzes the oxidation of glycine with high specificity. This process is coupled to the redox conversion of Prussian blue in the presence of hydrogen peroxide originating from the enzymatic reaction. The optimized tailoring of the biosensor design consists of the effective encapsulation of the quinoprotein in a chitosan matrix with the posterior addition of an outer Nafion layer, which is here demonstrated to suppress matrix interference. This is particularly important in the case of ascorbic acid, which is known to influence the redox behavior of the Prussian blue. The analytical performance of the biosensor demonstrates fast response time (<7 s), acceptable reversibility, reproducibility, and stability (<6% variation) as well as a wide linear range of response (25-500 μM) that covers healthy (and even most unhealthy) physiological levels of glycine in blood/serum, urine and sweat. A total of 6 real samples from healthy patients and animals were analyzed: two serum, two urine and two sweat samples. The results were validated via commercially available fluorescence kit, displaying discrepancy of less than 9% in all the samples. The unique analytical features and effortless preparation of the new glycine biosensor position it at the forefront of current technologies towards decentralized clinical applications and sport performance monitoring.
The hydrovoltaic effect, based on interactions at the solid-liquid interface, offers a promising route for ion sensing. However, it is hampered by long response times, typically several minutes, due to slow ion diffusion equilibrium in nanochannels. Here, we demonstrate a rapid, flexible hydrovoltaic ion sensing strategy enabled by fast ion transport. Apart from the drag resistance reduction resulting from the ordered nanochannels and gravity elimination along the nanochannel direction, the liquid-driven effect concurrent with low-resistance shear flow at the liquid-liquid transport zone in semi-dry nanochannels are proposed to achieve an open-circuit voltage exceeding 4.0 V within 0.17 s, being two orders of magnitude faster than previous works with infiltration channels. Moreover, the obtained flexible hydrovoltaic device exhibits a wide ion sensing range of 10−7 to 100 M, a maximum sensitivity up to −1.69 V dec-1 for NaCl, and distinctive multi-dimensional signals, enabling its application in selective ion sensing and sweat electrolyte monitoring.
Glycine monitoring is gaining importance as a biomarker in clinical analysis due to its involvement in multiple physiological functions, which results in glycine being one of the most analyzed biomolecules for diagnostics. This growing demand requires faster and more reliable, while affordable, analytical methods that can replace the current gold standard for glycine detection, which is based on sample extraction with subsequent use of liquid chromatography or fluorometric kits for its quantification in centralized laboratories. This work discusses electrochemical sensors and biosensors as an alternative option, focusing on their potential application for glycine determination in blood, urine, and cerebrospinal fluid, the three most widely used matrices for glycine analysis with clinical meaning. For electrochemical sensors, voltammetry/amperometry is the preferred readout (10 of the 13 papers collected in this review) and metal-based redox mediator modification is the predominant approach for electrode fabrication (11 of the 13 papers). However, none of the reported electrochemical sensors fulfill the requirements for direct analysis of biological fluids, most of them lacking appropriate selectivity, linear range of response, and/or capability of measuring at physiological conditions. Enhanced selectivity has been recently reported using biosensors (with an enzyme element in the electrode design), although this is still a very incipient approach. Currently, despite the benefits of electrochemistry, only optical biosensors have been successfully reported for glycine detection and, from all the inspected works, it is clear that bioengineering efforts will play a key role in the embellishment of selectivity and storage stability of the sensing element in the sensor.
In pursuit of calibration-free all-solid-state ion-selective electrodes (ISEs), we propose a coulometry strategy based on thin-layer samples confined adjacent to the ion-selective membrane (ISM) surface, with the system being controlled under a cathodic potential sweep. The ion-to-electron transducer in the ISE is the conducting polymer poly(3-octylthiophene) (POT), the oxidation state of which changes upon the application of a cathodic sweep and triggers the accumulation of the preferred cation in the ISM. This accumulation is provided of absolute nature (i.e., the cation concentration is totally depleted in the sample) when the capacity of the membrane encompasses the charge of the cation of interest in the sample (K+ in this case). As such, the ion exchanger content of the ISM is fixed to 18 μC, being able to accumulate a K+ concentration from the solution in the range of 5-40 μM. The charge transfer in the POT film ultimately leads to the K+ transfer at the ISM-sample interface, depleting its content in the thin-layer sample with demonstrated efficiency (∼100% at 5 and 1 mV s-1). The charge is directly proportional to the corresponding concentration via the Faraday law, constituting the core principle of the calibration-free approach. In essence, there is no need of calibrating the sensor, because the K+ concentration can be obtained from the charge by knowing the sample volume with certain precision (volume of 5 μL, with the sample thickness being 100 ± 5 μm). The conceptual innovation introduced in this Letter is accompanied by the validated calibration-free detection of K+ in five real samples, demonstrating the plausibility of the approach to contribute to the measurement science field, especially in the direction of fulfilling the gap between benchtop trials and the end users of electrochemical sensors. It is key to put efforts into calibration-free sensors to address real world applications such as point-of-care, wearable sensors for well-being, and environmental in situ monitoring, among others.