Lijuan Lan

Dr. Lijuan Lan


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FCFei Cheng
Fei Cheng
CYChao Yang
Chao Yang
Can ZhouCan Zhou
Can Zhou
LLLijuan Lan
Lijuan Lan
HZHongqiu Zhu
Hongqiu Zhu
YLYonggang Li
Yonggang Li
Excessive discharge of heavy metal ions will aggravate environment pollution and threaten human health. Thus, it is of significance to real-time detect metal ions and control discharge in the metallurgical wastewater. We developed an accurate and rapid approach based on the singular perturbation spectrum estimator and extreme gradient boosting (SPSE-XGBoost) algorithms to simultaneously determine multi-metal ion concentrations by UV–vis spectrometry. In the approach, the spectral data is expanded by multi-order derivative preprocessing, and then, the sensitive feature bands in each spectrum are extracted by feature importance (VI score) ranking. Subsequently, the SPSE-XGBoost model are trained to combine multi-derivative features and to predict ion concentrations. The experimental results indicate that the developed “Expand-Extract-Combine” strategy can not only overcome problems of background noise and spectral overlapping but also mine the deeper spectrum information by integrating important features. Moreover, the SPSE-XGBoost strategy utilizes the selected feature subset instead of the full-spectrum for calculation, which effectively improves the computing speed. The comparisons of different data processing methods are conducted. It outcomes that the proposed strategy outperforms other routine methods and can profoundly determine the concentrations of zinc, copper, cobalt, and nickel with the lowest RMSEP. Therefore, our developed approach can be implemented as a promising mean for real-time and on-line determination of multi-metal ion concentrations in zinc hydrometallurgy.

22 February 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
JGJingxuan Geng
Jingxuan Geng
CYChunhua Yang
Chunhua Yang
LLLijuan Lan
Lijuan Lan
YLYonggang Li
Yonggang Li
JHJie Han
Jie Han
CZCan Zhou
Can Zhou

19 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LLLijuan Lan
Lijuan Lan
长张长圣 张
长圣 张
YWYibo Wang
Yibo Wang
YXYu Xie
Yu Xie
LWLuheng Wang
Luheng Wang
CYChao Yang
Chao Yang
This article presents a gas sensing method based on long-tune natural logarithmic wavelength modulation spectroscopy (long-tune ln-WMS) and explores means to improve its accuracy. The long-tune spectrum can detect multiple gases with high precision. In ln-WMS, due to the natural logarithm algorithm, the harmonic magnitude which is related to gas concentration would not be affected by the light intensity fluctuations. However, the background signal of the harmonic will become strong and nonlinear in the long-tune spectrum. Three CO2 absorption lines and one H2O line near 2004 nm are applied to verify the proposed theory. The effects of light intensity, modulation depth, gas concentration, and phase shift on the harmonics are tested separately through both simulations and experiments. The results reveal that our proposed method can always keep the harmonics at their maximum which ensures high measurement precision. Moreover, the background signal only varies with the modulation depth, not the concentration and light intensity. Even the mechanical vibrations cannot disturb the harmonics, which enables the proposed method to be suitable for gas detection in harsh environments, especially for heavy dust and severe mechanical vibrations. The CO2 concentration detection results indicate that when the background is eliminated, the accuracy can be achieved with a relative error of below 0.5%, while the error would be greater than 5% with background presence. The proposed long-tune ln-WMS method is effective for trace gas detection (weak absorption) or over-modulation conditions and has potential applications in field inspection.

4 March 2021
Verified
Other
Open access
JGJingxuan Geng
Jingxuan Geng
CYChao Yang
Chao Yang
LLLijuan Lan
Lijuan Lan
JHJie Han
Jie Han
FZFengxue Zhang
Fengxue Zhang
YLYonggang Li
Yonggang Li
The online automatic detection for the concentration of total nitrogen (TN) is a critical problem in wastewater treatment plants (WWTPs). The over-discharge of TN can cause severe environmental problems such as aquatic eutrophication and ecosystem dysfunction, and the TN concentration in each wastewater treatment process can also reflect the processing statement of WWTPs and ensure its stable operation. However, determining the TN concentration timely is always a difficult task. According to the traditional TN detection approach, the concentration of TN is determined after the oxidative digestion process, which is a complex chemical reaction process and usually requires 30 minutes to 1 hour. Considering the actual operation situation, this traditional method can hardly satisfy the real-time requirement of WWTPs, which can only be used as a kind of validation approach. To solve this problem, in this paper, we design a novel automatic detection prototype of TN. Instead of determining the concentration of TN after the process of oxidative digestion, the ultraviolet spectrum is used to non-destructive detect the concentration of nitrate during the whole oxidative digestion process. Based on the principle of competitive response and chemical reaction kinetics, for different water samples with different TN concentrations, their oxidative digestion processes are different even in the early reaction stage. Therefore, we can use the early reaction properties to determine the TN concentration, thereby shortening the necessary detection time. Based on experimental data collected from real water samples, our prototype can not only efficiently shorten the detection time of the TN concentration, but also ensure satisfactory detection accuracy.

4 March 2021
Verified
Other
Open access
WLWenting Li
Wenting Li
CYChao Yang
Chao Yang
JHJie Han
Jie Han
FZFengxue Zhang
Fengxue Zhang
LLLijuan Lan
Lijuan Lan
YLYonggang Li
Yonggang Li
Municipal wastewater treatment plants (WWTPs) reuse domestic sewage, industrial wastewater, and rainfall runoff to realize sustainable utilization of fresh water resources. In order to guarantee the safety, reliability, and profitability of the WWTP, efficient process monitoring and control is becoming increasingly important. However, due to the economic and technical requirements, it is infeasible to place sensors at every process parameter location. Therefore, it is necessary to design the optimal sensor placement scheme which leads to maximum information gain about the plant conditions. Practical issues present in the WWTP, such as harsh physical conditions, fluctuation of water quantity, and variability in process parameters, make the optimal sensor placement problem an especially complicated one. Furthermore, sensors placement problem contains multiple objectives with complex nonlinear relationship. This study focuses on obtaining the optimal flow sensor placement scheme of the WWTP in terms of cost, information richness and redundancy. First, based on the graph theory and structural observability and redundancy criteria, a WWTP system model is constructed. Next, an industrial condition weighting factor setting strategy is introduced to measure the importance of the variables in different processing units, transforming the optimal flow sensor placement problem in the whole process into a discrete multi-objective optimization problem. Then, a novel metaheuristic method named discrete multi-objective state transition algorithm (DMOSTA) is proposed to obtain optimal trade-off solution set. Finally, an evaluation strategy is applied to select the best flow sensor placement scheme from the solution set. The proposed method is applied to three WWTPs with different dimensions. Comparative results show that the optimal flow sensor placement scheme based on the proposed method has the best comprehensive performance in regard to senor cost, process variable observability, sensor redundancy, and computational cost.