长圣 张

Mr. 长圣 张

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LLLijuan Lan
Lijuan Lan
YWYibo Wang
Yibo Wang
YXYu Xie
Yu Xie
长张长圣 张
长圣 张
HYHaoyang Yu
Haoyang Yu
CYChao Yang
Chao Yang
This paper presents a novel gas concentration detection approach based on wavelength modulation spectroscopy and linear convolution (LC-WMS). The linear convolution is first time utilized in the WMS measurement system to demodulate the absorption spectrum, and then to obtain the absolute harmonic signals related to the gas concentration. Theoretical and experimental results show that when the absorption signal is convolved with a whole-cycle reference signal, the harmonic signals can be acquired without the need of lock-in amplifier (LIA) and low-pass filter. The linear convolution calculation process is regarded as a combination of demodulation and low-pass filter as in the conventional demodulation system (e.g. LIA). Simulations demonstrate that appropriately increasing the cycles of reference signal (not exceeding five cycles) can help to decrease the noise of the harmonic signals. Experimental results show that the proposed LC-WMS approach can obtain a comparable accuracy as the conventional LIA in CO 2 and H 2 O concentration measurement with concentration errors less than 5 ppm and 0.05‰, respectively. The long-term measurement shows that this method can be used for real-time detection with large concentration fluctuations. Since the linear convolution process gets rid of the problem caused by the magnitude gain response in low-pass filter, the proposed LC-WMS method can not only obtain the absolute harmonic signal without calibration but also simplify the detection process. Thus, it has potential applications in industrial field measurements.

19 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LLLijuan Lan
Lijuan Lan
长张长圣 张
长圣 张
YWYibo Wang
Yibo Wang
YXYu Xie
Yu Xie
LWLuheng Wang
Luheng Wang
CYChao Yang
Chao Yang
This article presents a gas sensing method based on long-tune natural logarithmic wavelength modulation spectroscopy (long-tune ln-WMS) and explores means to improve its accuracy. The long-tune spectrum can detect multiple gases with high precision. In ln-WMS, due to the natural logarithm algorithm, the harmonic magnitude which is related to gas concentration would not be affected by the light intensity fluctuations. However, the background signal of the harmonic will become strong and nonlinear in the long-tune spectrum. Three CO2 absorption lines and one H2O line near 2004 nm are applied to verify the proposed theory. The effects of light intensity, modulation depth, gas concentration, and phase shift on the harmonics are tested separately through both simulations and experiments. The results reveal that our proposed method can always keep the harmonics at their maximum which ensures high measurement precision. Moreover, the background signal only varies with the modulation depth, not the concentration and light intensity. Even the mechanical vibrations cannot disturb the harmonics, which enables the proposed method to be suitable for gas detection in harsh environments, especially for heavy dust and severe mechanical vibrations. The CO2 concentration detection results indicate that when the background is eliminated, the accuracy can be achieved with a relative error of below 0.5%, while the error would be greater than 5% with background presence. The proposed long-tune ln-WMS method is effective for trace gas detection (weak absorption) or over-modulation conditions and has potential applications in field inspection.

6 March 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LLLijuan Lan
Lijuan Lan
YXYu Xie
Yu Xie
长张长圣 张
长圣 张
Can ZhouCan Zhou
Can Zhou
YLYonggang Li
Yonggang Li
WGWeihua Gui
Weihua Gui
Online detection of CO2 emissions can provide important data support for low-carbon operation of process industries. However, the cumbersome calibration process often limits the applications of gas sensors in field measurement. This paper develops a total calibration-free gas detection method based on natural logarithm and linear convolution algorithms in TDLAS- (ln-LC-WMS) and investigates its optimization in applications. Logarithm processing effectively eliminates the influence of light intensity on the harmonic, while linear convolution accurately quantifies the amplitude gain, which overcomes the problem of inaccurate filtering gain in the traditional demodulation method. Thereby, the harmonic is obtained with an accurate absolute amplitude that is positively correlated with gas concentration, and the gas concentration can be obtained without calibration. Meanwhile, to deal with the detection error caused by the mismatch between the preset and actual concentrations in the concentration inversion, an iterative process is generated to calculate the accurate gas concentration. To test the feasibility of the proposed method, three CO2 absorption lines near 2004 nm are applied for experimental verification. The experimental results indicate that to overcome the inaccurate preset concentration, within CO2 concentration of 5%, two iterations are sufficient to obtain the accurate result. Continuous measurements of a fixed CO2 concentration at different temperatures show high precision and stability, demonstrating that the proposed method is reliable and can obtain the gas concentration without additional calibration. The proposed method is expected to simplify the detection equipment and avoid calibration operations, which has good industrial application prospects.