Anke Klingner

Dr. Anke Klingner

Physics department, The German University in Cairo (GUC)
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
VMVeronika Magdanz
Veronika Magdanz
IKIslam S. M. Khalil
Islam S. M. Khalil
JSJuliane Simmchen
Juliane Simmchen
GFGuilherme P. Furtado
Guilherme P. Furtado
SMSumit Mohanty
Sumit Mohanty
SMSarthak Misra
Sarthak Misra
IRONSperms are microrobots templated by sperm cells, powered by magnetic fields, loaded with drugs, and localized by ultrasound.

11 January 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
DMDalia Mahdy
Dalia Mahdy
ASAhmed El Sharkawy
Ahmed El Sharkawy
RMRamez R. Moustafa
Ramez R. Moustafa
ATAhmet Fatih Tabak
Ahmet Fatih Tabak
MSMetin Sitti
Metin Sitti
A simple way to mitigate the potential negative side-effects associated with chemical lysis of a blood clot is to tear its fibrin network via mechanical rubbing using a helical robot. Here, we achieve mechanical rubbing of blood clots under ultrasound guidance and using external magnetic actuation. Position of the helical robot is determined using ultrasound feedback and used to control its motion toward the clot, whereas the volume of the clots is estimated simultaneously using visual feedback. We characterize the shear modulus and ultimate shear strength of the blood clots to predict their removal rate during rubbing. Our in vitro experiments show the ability to move the helical robot controllably toward clots using ultrasound feedback with average and maximum errors of ${\text{0.84}\pm \text{0.41}}$ and 2.15 mm, respectively, and achieve removal rate of $-\text{0.614} \pm \text{0.303}$ mm $^{3}$ /min at room temperature ( ${\text{25}}^{\circ }$ C) and $-\text{0.482} \pm \text{0.23}$ mm $^{3}$ /min at body temperature (37 $^{\circ}$ C), under the influence of two rotating dipole fields at frequency of 35 Hz. We also validate the effectiveness of mechanical rubbing by measuring the number of red blood cells and platelets past the clot. Our measurements show that rubbing achieves cell count of $(\text{46} \pm \text{10.9}) \times \text{10}^{4}$ cell/ml, whereas the count in the absence of rubbing is $(\text{2} \pm \text{1.41}) \times \text{10}^{4}$ cell/ml, after 40 min.

19 February 2005 in Journal of Physics: Condensed Matter
Verified
Journal Article
Closed access
FMF Mugele
F Mugele
AKAnke Klingner
Anke Klingner
JBJ Buehrle
J Buehrle
DSD Steinhauser
D Steinhauser
SHS Herminghaus
S Herminghaus

15 February 2013 in Biomacromolecules
Verified
Journal Article
Closed access
HEHassan A. Abd El-Rehim
Hassan A. Abd El-Rehim
ASAhmed E. Swilem
Ahmed E. Swilem
AKAnke Klingner
Anke Klingner
EHEl-Sayed A. Hegazy
El-Sayed A. Hegazy
AHAshraf A. Hamed
Ashraf A. Hamed

18 July 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
ATAhmet Fatih Tabak
Ahmet Fatih Tabak
AKAnke Klingner
Anke Klingner
MSMetin Sitti
Metin Sitti
We investigate the microswimming behaviour of robotic sperms in viscous fluids. These robotic sperms are fabricated from polystyrene dissolved in dimethyl formamide and iron-oxide nanoparticles. This composition allows the nanoparticles to be concentrated within the bead of the robotic sperm and provide magnetic dipole, whereas the flexibility of the ultra-thin tail enables flagellated locomotion using magnetic fields in millitesla range. We show that these robotic sperms have similar morphology and swimming behaviour to those of sperm cells. Moreover, we show experimentally that our robotic sperms swim controllably at an average speed of approximately one body length per second (around 125 μm s−1), and they are relatively faster than the microswimmers that depend on planar wave propulsion in low-Reynolds number fluids.

5 February 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
IKIslam S. M. Khalil
Islam S. M. Khalil
ATAhmet Fatih Tabak
Ahmet Fatih Tabak
YHYoussef Hamed
Youssef Hamed
MTMohamed Tawakol
Mohamed Tawakol
AKAnke Klingner
Anke Klingner
MSMetin Sitti
Metin Sitti
A soft two-tailed microrobot in low Reynolds number fluids does not achieve forward locomotion by identical tails regardless to its wiggling frequency. If the tails are nonidentical, zero forward locomotion is also observed at specific oscillation frequencies (which we refer to as the reversal frequencies), as the propulsive forces imparted to the fluid by each tail are almost equal in magnitude and opposite in direction. We find distinct reversal frequencies for the two-tailed microrobots based on their tail length ratio. At these frequencies, the microrobot achieves negligible net displacement under the influence of a periodic magnetic field. This observation allows us to fabricate groups of microrobots with tail length ratio of 1.24 ± 0.11, 1.48 ± 0.08, and 1.71 ± 0.09. We demonstrate selective actuation of microrobots based on prior characterization of their reversal frequencies. We also implement simultaneous flagellar propulsion of two microrobots and show that they can be controlled to swim along the same direction and opposite to each other using common periodic magnetic fields. In addition, independent motion control of two microrobots is achieved toward two different reference positions with average steady-state error of 110.1 ± 91.8 μm and 146.9 ± 105.9 μm.