Wen-Li Wu

Dr. Wen-Li Wu


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2002 in Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
Verified
Journal Article
Closed access
PDF file
JLJoseph L. Lenhart
Joseph L. Lenhart
RJRonald L. Jones
Ronald L. Jones
ELEric K. Lin
Eric K. Lin
CSChristopher L. Soles
Christopher L. Soles
WWWen-Li Wu
Wen-Li Wu
MAMarie Angelopoulos
Marie Angelopoulos
The performance of chemically amplified photoresists is extremely sensitive to interfacial and surface phenomena, which cause deviations in the pattern profile near an interface. Striking examples include T-topping or closure near the air/resist interface and footing or undercutting near the resist/substrate interface. One focus of our research is to identify mechanisms that cause lithographic patterns to deviate near interfaces. Near edge x-ray absorption fine structure (NEXAFS) is a powerful tool that can be developed and adapted to probe for detailed chemical information near lithographically relevant interfaces. NEXAFS showed that our model resist films exhibited significant surface segregation of the photo acid generator (PAG) at the air interface. The PAG surface mole fraction was 20–70 times greater than the bulk mole fraction and the amount of surface segregation was dependent on the polarity of the polymer. NEXAFS also revealed that the PAG surface fraction was reduced after a postexposure bake. In the absence of delay times between processing steps, the PAG surface enhancement led to a faster deprotection reaction rate near the air interface relative to the bulk. However, when significant postexposure delay times were incorporated into the processing, NEXAFS showed that the surface deprotection reaction was incomplete after postexposure baking. Comparison of carbon K-edge, and oxygen K-edge NEXAFS spectra showed that the incomplete surface reaction was localized at the air interface. While delay effects have previously been linked to deterioration of resist performance, NEXAFS proved to be a valuable tool for providing detailed chemical specificity about the resist surface composition and deprotection kinetics.

3 April 2023 in Journal of Micro/Nanopatterning, Materials, and Metrology
Verified
Journal Article
Open access
PDF file
WWWen-Li Wu
Wen-Li Wu
RKR. Joseph Kline
R. Joseph Kline
RJRonald L. Jones
Ronald L. Jones
HLHae-Jeong Lee
Hae-Jeong Lee
ELEric K. Lin
Eric K. Lin
CSChristopher L. Soles
Christopher L. Soles
An x-ray scattering based metrology was conceived over 20 years ago as part of a collaboration between National Institute of Standards and Technology (NIST) and International Business Machines Corporation (IBM) to evaluate the performance of lithographic patterning materials for the semiconductor industry. This methodology treated a periodic array of lithographic structures as a diffraction grating and focused on extracting the physical dimensions of the structures in the grating by analyzing the diffraction patterns. In the early stages of the work the focus was on developing the transmission small-angle x-ray scattering (tSAXS) as a metrology tool to measure the critical dimensions (CD) of the lithographic features vital to the integrated circuit chip fabrication. Later, the focus shifted to include grazing incident small-angle x-ray scattering and x-ray reflectivity as parts of the CD metrology tool due to their unique capabilities. Frequently the term critical dimension small-angle x-ray scattering (CDSAXS) has been used as a synonym for the metrology of using tSAXS for CD measurements without mentioning transmission. Various milestones in the CDSAXS development are reviewed in this article together with some prospects regarding the future growth of x-ray-based metrology for complex three-dimensional nanostructures important to semiconductor industries.

10 October 2012 in ACS Macro Letters
Verified
Journal Article
Closed access
GPGinusha M. Perera
Ginusha M. Perera
CWChengqing Wang
Chengqing Wang
MDManolis Doxastakis
Manolis Doxastakis
RKR. Joseph Kline
R. Joseph Kline
WWWen-Li Wu
Wen-Li Wu
GSGila E. Stein
Gila E. Stein

1 June 2023 in Surface Topography: Metrology and Properties
Verified
Journal Article
Closed access
PDF file
WFW E Fu
W E Fu
BHB C He
B C He
WWWen-Li Wu
Wen-Li Wu
Transmission small angle x-ray scattering (tSAXS) has been developed as a metrology for the critical dimension (CD) measurements to facilitate integrated circuit (IC) chip fabrications. Synchrotron x-ray sources were used for their high brilliance and a wavelength less than one tenth of a nanometer was chosen for its high penetration power to enable transmission measurements through a silicon wafer with a nominal thickness of 0.7 mm. A major hold back preventing tSAXS from reaching wide applications in IC fabrication is the lack of high brilliance laboratory-based x-ray sources. Within the last few years, even without any major breakthrough in x-ray source technology, this tSAXS metrology has finally been used for 3D NAND and DRAM, i.e., memory chips with tall or high aspect ratio (HAR) architectures. The scattering intensities from HAR structures will be discussed quantitatively in terms of the sample height and the effective longitudinal coherence length of the incident x-ray.

7 August 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
CLChun Ting Liu
Chun Ting Liu
BHBo-Ching He
Bo-Ching He
GCGuo-Dung Chen
Guo-Dung Chen
ACAlice Chinghsuan Chang
Alice Chinghsuan Chang
WWWen-Li Wu
Wen-Li Wu
WFWei-En Fu
Wei-En Fu
The notion of an effective longitudinal coherence length with its value much greater than λ2/(2Δλ) has been adopted in small-angle X-ray scattering communities for years, where λ and Δλ denote the incident wavelength and its spread, respectively. Often the implications of the effective longitudinal coherence length do not even enter considerations in the designing and data treatment of small-angle scattering experiments. In this work, conventional transmission small-angle X-ray scattering (tSAXS) was performed to reveal a clear angular dependence on effective longitudinal coherence length. The measured values of effective longitudinal coherence length can be as high as one millimeter, whereas the value of calculated λ2/(2Δλ) is in nanometers.

1 May 2008
Verified
Conference Paper
Closed access
CWChengqing Wang
Chengqing Wang
KCKwang-Woo Choi
Kwang-Woo Choi
WFWei-En Fu
Wei-En Fu
RJRonald L. Jones
Ronald L. Jones
DHDerek L. Ho
Derek L. Ho
BBBenjamin Bunday
Benjamin Bunday
Critical dimension small angle X-ray scattering (CD- SAXS) is a metrology platform that is capable of measuring the average cross section and linewidth roughness (LWR) in test patterns with pitches ranging from 10 to 500 nm with sub-nm precision. These capabilities are obtained by measuring and modeling the scattering intensities of a collimated X-ray beam with sub-nm wavelength from a periodic pattern, such as those found in optical scatterometry targets. In this work, we evaluated the capability of both synchrotron-based and laboratory-scale CD-SAXS for characterizing LWR from measurements of periodic line/space patterns fabricated with extreme ultraviolet (EUV) lithography with sub-50 nm linewidths and designed with programmed roughness amplitude and frequency. For these patterns, CD-SAXS can provide high precision data on cross section dimension, including sidewall angle, line height, linewidth and pitch, as well as the amplitude of LWR. We will also discuss the status of ongoing efforts to compare quantitatively the CD- SAXS data with top-down scanning electron microscopy (CD- SEM) measurements.