Antonia Silvestri

Dr. Antonia Silvestri

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2017 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
Yu Shrike ZhangYu Shrike Zhang
Yu Shrike Zhang
JAJulio Aleman
Julio Aleman
SSSu Ryon Shin
Su Ryon Shin
TKTugba Kilic
Tugba Kilic
DKDuckjin Kim
Duckjin Kim
Ali  KhademhosseiniAli Khademhosseini
Ali Khademhosseini
Significance: Monitoring human organ-on-a-chip systems presents a significant challenge, where the capability of in situ continual monitoring of organ behaviors and their responses to pharmaceutical compounds over extended periods of time is critical in understanding the dynamics of drug effects and therefore accurate prediction of human organ reactions. In this work, we report a fully integrated modular physical, biochemical, and optical sensing platform, interfaced through a fluidics-routing breadboard with a multi–organ-on-a-chip system to achieve in situ, continual, and automated sensing of microenvironment biophysical and biochemical parameters. It is anticipated that our platform technology that is conveniently compatible with existing organ-on-a-chip models will potentially enhance their performance in drug screening by providing a multitude of sensing data not previously available.

12 September 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
SSSu Ryon Shin
Su Ryon Shin
YZYu Shrike Zhang
Yu Shrike Zhang
DKDuck-Jin Kim
Duck-Jin Kim
AMAhmad Manbohi
Ahmad Manbohi
HAHuseyin Avci
Huseyin Avci
Ali  KhademhosseiniAli Khademhosseini
Ali Khademhosseini

5 May 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
NTNicola Di Trani
Nicola Di Trani
ASAntonia Silvestri
Antonia Silvestri
ASAntons Sizovs
Antons Sizovs
YWYu Wang
Yu Wang
DEDonald R. Erm
Donald R. Erm
Alessandro GrattoniAlessandro Grattoni
Alessandro Grattoni
Patient-centered therapeutic management for chronic medical conditions is a desired but unmet need, largely attributable to the lack of adequate technologies for tailored drug administration. While triggered devices that control the delivery of therapeutics exist, they often rely on impractical continuous external activation. As such, next generation continuously tunable drug delivery systems independent of sustained external activation remain an elusive goal. Here we present the development and demonstration of a silicon carbide (SiC)-coated nanofluidic membrane that achieves reproducible and tunable control of drug release via electrostatic gating. By applying a low-intensity voltage to a buried electrode, we showed repeatable and reproducible in vitro release modulation of three model analytes. A small fluorophore (Alexa Fluor 647), a large polymer poly(sodium 4-styrenesulfonate) and a medically relevant agent (DNA), were selected as representatives of small molecule therapeutics, polymeric drug carriers, and biological therapeutics, respectively. Unlike other drug delivery systems, our technology performed consistently over numerous cycles of voltage modulation, for over 11 days. Importantly, low power consumption and minimal leakage currents were achieved during the study. Further, the SiC coating maintained integrity and chemical inertness, shielding the membrane from degradation under simulated physiological and accelerated conditions for over 4 months. Through leveraging the flexibility offered by electrostatic gating control, our technology provides a valuable strategy for tunable delivery, setting the foundation for the next generation of drug delivery systems.

3 June 2019 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
NTNicola Di Trani
Nicola Di Trani
ASAntonia Silvestri
Antonia Silvestri
GBGiacomo Bruno
Giacomo Bruno
TGThomas Geninatti
Thomas Geninatti
CCCorrine Ying Xuan Chua
Corrine Ying Xuan Chua
Alessandro GrattoniAlessandro Grattoni
Alessandro Grattoni
Chronic diseases such as hypertension and rheumatoid arthritis are persistent ailments that require personalized lifelong therapeutic management. However, the difficulty of adherence to strict dosing schedule compromises therapeutic efficacy and safety. Moreover, the conventional one-size-fits-all treatment approach is increasingly challenged due to the intricacies of inter- and intra-individual variabilities. While accelerated technological advances have led to sophisticated implantable drug delivery devices, flexibility in dosage and timing modulation to tailor precise treatment to individual needs remains an elusive goal. Here we describe the development of a subcutaneously implantable remote-controlled nanofluidic device capable of sustained drug release with adjustable dosing and timing. By leveraging a low intensity electric field to modify the concentration driven diffusion across a nanofluidic membrane, the rate of drug administration can be increased, decreased or stopped via Bluetooth remote command. We demonstrate in vitro the release modulation of enalapril and methotrexate, first-line therapeutics for treatment of hypertension and rheumatoid arthritis, respectively. Further, we show reliable remote communication and device biocompatibility via in vivo studies. Unlike a pulsatile release regimen typical of some conventional controlled delivery systems, our implant offers a continuous drug administration that avoids abrupt fluctuations, which could affect response and tolerability. Our system could set the foundation for an on-demand delivery platform technology for long term management of chronic diseases.

19 July 2020 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
NTNicola Di Trani
Nicola Di Trani
ASAntonia Silvestri
Antonia Silvestri
YWYu Wang
Yu Wang
DDDanilo Demarchi
Danilo Demarchi
XLXuewu Liu
Xuewu Liu
Alessandro GrattoniAlessandro Grattoni
Alessandro Grattoni
Individualized long-term management of chronic pathologies remains an elusive goal despite recent progress in drug formulation and implantable devices. The lack of advanced systems for therapeutic administration that can be controlled and tailored based on patient needs precludes optimal management of pathologies, such as diabetes, hypertension, rheumatoid arthritis. Several triggered systems for drug delivery have been demonstrated. However, they mostly rely on continuous external stimuli, which hinder their application for long-term treatments. In this work, we investigated a silicon nanofluidic technology that incorporates a gate electrode and examined its ability to achieve reproducible control of drug release. Silicon carbide (SiC) was used to coat the membrane surface, including nanochannels, ensuring biocompatibility and chemical inertness for long-term stability for in vivo deployment. With the application of a small voltage (≤ 3 V DC) to the buried polysilicon electrode, we showed in vitro repeatable modulation of membrane permeability of two model analytes—methotrexate and quantum dots. Methotrexate is a first-line therapeutic approach for rheumatoid arthritis; quantum dots represent multi-functional nanoparticles with broad applicability from bio-labeling to targeted drug delivery. Importantly, SiC coating demonstrated optimal properties as a gate dielectric, which rendered our membrane relevant for multiple applications beyond drug delivery, such as lab on a chip and micro total analysis systems (µTAS).

15 July 2021 in Membranes
Verified
Journal Article
Open access
PDF file
ASAntonia Silvestri
Antonia Silvestri
NTNicola Di Trani
Nicola Di Trani
GCGiancarlo Canavese
Giancarlo Canavese
PRPaolo Motto Ros
Paolo Motto Ros
LILeonardo Iannucci
Leonardo Iannucci
Alessandro GrattoniAlessandro Grattoni
Alessandro Grattoni
Manipulation of ions and molecules by external control at the nanoscale is highly relevant to biomedical applications. We report a biocompatible electrode-embedded nanofluidic channel membrane designed for electrofluidic applications such as ionic field-effect transistors for implantable drug-delivery systems. Our nanofluidic membrane includes a polysilicon electrode electrically isolated by amorphous silicon carbide (a-SiC). The nanochannel gating performance was experimentally investigated based on the current-voltage (I-V) characteristics, leakage current, and power consumption in potassium chloride (KCl) electrolyte. We observed significant modulation of ionic diffusive transport of both positively and negatively charged ions under physical confinement of nanochannels, with low power consumption. To study the physical mechanism associated with the gating performance, we performed electrochemical impedance spectroscopy. The results showed that the flat band voltage and density of states were significantly low. In light of its remarkable performance in terms of ionic modulation and low power consumption, this new biocompatible nanofluidic membrane could lead to a new class of silicon implantable nanofluidic systems for tunable drug delivery and personalized medicine.