Md Billal Hossain

Mr. Md Billal Hossain

Graduate Research Assistant
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2019 in IEEE Access
Verified
Journal Article
Open access
Md Billal HossainMd Billal Hossain
Md Billal Hossain
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
AWAllan J. Walkey
Allan J. Walkey
DMDavid D. McManus
David D. McManus
KCKi Chon
Ki Chon
We developed a novel method for QRS complex and P wave detection in the electrocardiogram (ECG) signal. The approach reconstructs two different signals for the purpose of QRS and P wave detection from the modes obtained by the complete ensemble empirical mode decomposition with adaptive noise, taking only those modes that best represent the signal dynamics. This approach eliminates the need for conventional filtering. We first detect QRS complex locations, followed by removal of QRS complexes from the reconstructed signal to enable P wave detection. We introduce a novel method of P wave detection from both the positive and negative amplitudes of the ECG signal and an adaptive P wave search approach to find the true P wave. Our detection method automatically identifies P waves without prior information. The proposed method was validated on two well-known annotated databases-the MIT BIH Arrythmia database (MITDB) and The QT database (QTDB). The QRS detection algorithm resulted in 99.96% sensitivity, 99.9% positive predictive value, and an error of 0.13% on all validation databases. The P wave detection method had better performance when compared to other well-known methods. The performance of our P wave detection on the QTDB showed a sensitivity of 99.96%, a positive predictive value of 99.47%, and the mean error in P peak detection was less than or equal to one sample (4 ms) on average.

14 April 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JLJesus Lazaro
Jesus Lazaro
Natasa ReljinNatasa Reljin
Natasa Reljin
Md Billal HossainMd Billal Hossain
Md Billal Hossain
YNYeonsik Noh
Yeonsik Noh
Pablo LagunaPablo Laguna
Pablo Laguna
KCKi Chon
Ki Chon
A wearable armband electrocardiogram (ECG) monitor has been used for daily life monitoring. The armband records three ECG channels, one electromyogram (EMG) channel, and tri-axial accelerometer signals. Contrary to conventional Holter monitors, the armband-based ECG device is convenient for long-term daily life monitoring because it uses no obstructive leads and has dry electrodes (no hydrogels), which do not cause skin irritation even after a few days. Principal component analysis (PCA) and normalized least mean squares (NLMS) adaptive filtering were used to reduce the EMG noise from the ECG channels. An artifact detector and an optimal channel selector were developed based on a support vector machine (SVM) classifier with a radial basis function (RBF) kernel using features that are related to the ECG signal quality. Mean HR was estimated from the 24-hour armband recordings from 16 volunteers in segments of 10 seconds each. In addition, four classical HR variability (HRV) parameters (SDNN, RMSSD, and powers at low and high frequency bands) were computed. For comparison purposes, the same parameters were estimated also for data from a commercial Holter monitor. The armband provided usable data (difference less than 10% from Holter-estimated mean HR) during 75.25%/11.02% (inter-subject median/interquartile range) of segments when the user was not in bed, and during 98.49%/0.79% of the bed segments. The automatic artifact detector found 53.85%/17.09% of the data to be usable during the non-bed time, and 95.00%/2.35% to be usable during the time in bed. The HRV analysis obtained a relative error with respect to the Holter data not higher than 1.37% (inter-subject median/interquartile range). Although further studies have to be conducted for specific applications, results suggest that the armband device has a good potential for daily life HR monitoring, especially for applications such as arrhythmia or seizure detection, stress assessment, or sleep studies.

6 November 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Syed Khairul BasharSyed Khairul Bashar
Syed Khairul Bashar
Md Billal HossainMd Billal Hossain
Md Billal Hossain
EDEric Ding
Eric Ding
AWAllan J. Walkey
Allan J. Walkey
DMDavid D. McManus
David D. McManus
KCKi Chon
Ki Chon
Sepsis is defined by life-threatening organ dysfunction during infection and is one of the leading causes of critical illness. During sepsis, there is high risk that new-onset of atrial fibrillation (AF) can occur, which is associated with significant morbidity and mortality. As a result, computer aided automated and reliable detection of new-onset AF during sepsis is crucial, especially for the critically ill patients in the intensive care unit (ICU). In this paper, a novel automated and robust two-step algorithm to detect AF from ICU patients using electrocardiogram (ECG) signals is presented. First, several statistical parameters including root mean square of successive differences, Shannon entropy, and sample entropy were calculated from the heart rate for the screening of possible AF segments. Next, Poincaré plot-based features along with P-wave characteristics were used to reduce false positive detection of AF, caused by the premature atrial and ventricular beats. A subset of the Medical Information Mart for Intensive Care (MIMIC) III database containing 198 subjects was used in this study. During the training and validation phases, both the simple thresholding as well as machine learning classifiers achieved very high segment-wise AF classification performance. Finally, we tested the performance of our proposed algorithm using two independent test data sets and compared the performance with two state-of-the-art methods. The algorithm achieved an overall 100% sensitivity, 98% specificity, 98.99% accuracy, 98% positive predictive value, and 100% negative predictive value on the subject-wise AF detection, thus showing the efficacy of our proposed algorithm in critically ill sepsis patients. The annotations of the data have been made publicly available for other investigators.

21 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Md Billal HossainMd Billal Hossain
Md Billal Hossain
YKYoungsun Kong
Youngsun Kong
Hugo Fernando Posada-QuinteroHugo Fernando Posada-Quintero
Hugo Fernando Posada-Quintero
KCKi Chon
Ki Chon
The most traditional sites for electrodermal activity (EDA) data collection, palmar locations such as fingers or palms, are not usually recommended for ambulatory monitoring given that subjects have to use their hands regularly during their daily activities, and therefore, alternative sites are often sought for EDA data collection. In this study, we collected EDA signals (n = 23 subjects, 19 male) from four measurement sites (forehead, back of neck, finger, and inner edge of foot) during cognitive stress and induction of mild motion artifacts by walking and one-handed weightlifting. Furthermore, we computed several EDA indices from the EDA signals obtained from different sites and evaluated their efficiency to classify cognitive stress from the baseline state. We found a high within-subject correlation between the EDA signals obtained from the finger and the feet. Consistently high correlation was also found between the finger and the foot EDA in both the phasic and tonic components. Statistically significant differences were obtained between the baseline and cognitive stress stage only for the EDA indices computed from the finger and the foot EDA. Moreover, the receiver operating characteristic curve for cognitive stress detection showed a higher area-under-the-curve for the EDA indices computed from the finger and foot EDA. We also evaluated the robustness of the different body sites against motion artifacts and found that the foot EDA location was the best alternative to other sites.

13 January 2022 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
Md Billal HossainMd Billal Hossain
Md Billal Hossain
HPHugo F. Posada-Quintero
Hugo F. Posada-Quintero
YKYoungsun Kong
Youngsun Kong
RMRiley McNaboe
Riley McNaboe
KCKi H. Chon
Ki H. Chon

21 November 2020 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
Md Billal HossainMd Billal Hossain
Md Billal Hossain
SBSyed Khairul Bashar
Syed Khairul Bashar
JLJesus Lazaro
Jesus Lazaro
NRNatasa Reljin
Natasa Reljin
YNYeonsik Noh
Yeonsik Noh
KCKi Chon
Ki Chon