Natasa Reljin

Dr. Natasa Reljin

InveniAI Corporation
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
SSSneh K. Sinha
Sneh K. Sinha
YNYeonsik Noh
Yeonsik Noh
Natasa ReljinNatasa Reljin
Natasa Reljin
GTGregory Martin Treich
Gregory Martin Treich
SHShirin Hajeb-M
Shirin Hajeb-M
GSGregory A. Sotzing
Gregory A. Sotzing

10 March 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
YNYunyoung Nam
Yunyoung Nam
YKYoungsun Kong
Youngsun Kong
BRBersain Reyes
Bersain Reyes
Natasa ReljinNatasa Reljin
Natasa Reljin
KCKi Chon
Ki Chon
Some smartphones have the capability to process video streams from both the front- and rear-facing cameras simultaneously. This paper proposes a new monitoring method for simultaneous estimation of heart and breathing rates using dual cameras of a smartphone. The proposed approach estimates heart rates using a rear-facing camera, while at the same time breathing rates are estimated using a non-contact front-facing camera. For heart rate estimation, a simple application protocol is used to analyze the varying color signals of a fingertip placed in contact with the rear camera. The breathing rate is estimated from non-contact video recordings from both chest and abdominal motions. Reference breathing rates were measured by a respiration belt placed around the chest and abdomen of a subject; reference heart rates (HR) were determined using the standard electrocardiogram. An automated selection of either the chest or abdominal video signal was determined by choosing the signal with a greater autocorrelation value. The breathing rate was then determined by selecting the dominant peak in the power spectrum. To evaluate the performance of the proposed methods, data were collected from 11 healthy subjects. The breathing ranges spanned both low and high frequencies (6–60 breaths/min), and the results show that the average median errors from the reflectance imaging on the chest and the abdominal walls based on choosing the maximum spectral peak were 1.43% and 1.62%, respectively. Similarly, HR estimates were also found to be accurate.

25 February 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
BRBersain Reyes
Bersain Reyes
Natasa ReljinNatasa Reljin
Natasa Reljin
YKYoungsun Kong
Youngsun Kong
YNYunyoung Nam
Yunyoung Nam
KCKi H. Chon
Ki H. Chon
Two parameters that a breathing status monitor should provide include tidal volume (VT ) and respiration rate (RR). Recently, we implemented an optical monitoring approach that tracks chest wall movements directly on a smartphone. In this paper, we explore the use of such noncontact optical monitoring to obtain a volumetric surrogate signal, via analysis of intensity changes in the video channels caused by the chest wall movements during breathing, in order to provide not only average RR but also information about VT and to track RR at each time instant (IRR). The algorithm, implemented on an Android smartphone, is used to analyze the video information from the smartphone's camera and provide in real time the chest movement signal from N = 15 healthy volunteers, each breathing at VT ranging from 300 mL to 3 L. These measurements are performed separately for each volunteer. Simultaneous recording of volume signals from a spirometer is regarded as reference. A highly linear relationship between peak-to-peak amplitude of the smartphone-acquired chest movement signal and spirometer VT is found (r 2 = 0.951 ± 0.042, mean ± SD). After calibration on a subject-by-subject basis, no statistically significant bias is found in terms of VT estimation; the 95% limits of agreement are -0.348 to 0.376 L, and the rootmean-square error (RMSE) was 0.182 ± 0.107 L. In terms of IRR estimation, a highly linear relation between smartphone estimates and the spirometer reference was found (r 2 = 0.999 ± 0.002). The bias, 95% limits of agreement, and RMSE are -0.024 breaths-per-minute (bpm), -0.850 to 0.802 bpm, and 0.414 ±0.178 bpm, respectively. These promising results show the feasibility of developing an inexpensive and portable breathing monitor, which could provide information about IRR as well as V T , when calibrated on an individual basis, using smartphones. Further studies are required to enable practical implementation of the proposed approach.

14 April 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JLJesus Lazaro
Jesus Lazaro
Natasa ReljinNatasa Reljin
Natasa Reljin
Md Billal HossainMd Billal Hossain
Md Billal Hossain
YNYeonsik Noh
Yeonsik Noh
Pablo LagunaPablo Laguna
Pablo Laguna
KCKi Chon
Ki Chon
A wearable armband electrocardiogram (ECG) monitor has been used for daily life monitoring. The armband records three ECG channels, one electromyogram (EMG) channel, and tri-axial accelerometer signals. Contrary to conventional Holter monitors, the armband-based ECG device is convenient for long-term daily life monitoring because it uses no obstructive leads and has dry electrodes (no hydrogels), which do not cause skin irritation even after a few days. Principal component analysis (PCA) and normalized least mean squares (NLMS) adaptive filtering were used to reduce the EMG noise from the ECG channels. An artifact detector and an optimal channel selector were developed based on a support vector machine (SVM) classifier with a radial basis function (RBF) kernel using features that are related to the ECG signal quality. Mean HR was estimated from the 24-hour armband recordings from 16 volunteers in segments of 10 seconds each. In addition, four classical HR variability (HRV) parameters (SDNN, RMSSD, and powers at low and high frequency bands) were computed. For comparison purposes, the same parameters were estimated also for data from a commercial Holter monitor. The armband provided usable data (difference less than 10% from Holter-estimated mean HR) during 75.25%/11.02% (inter-subject median/interquartile range) of segments when the user was not in bed, and during 98.49%/0.79% of the bed segments. The automatic artifact detector found 53.85%/17.09% of the data to be usable during the non-bed time, and 95.00%/2.35% to be usable during the time in bed. The HRV analysis obtained a relative error with respect to the Holter data not higher than 1.37% (inter-subject median/interquartile range). Although further studies have to be conducted for specific applications, results suggest that the armband device has a good potential for daily life HR monitoring, especially for applications such as arrhythmia or seizure detection, stress assessment, or sleep studies.

1 June 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Hugo Fernando Posada-QuinteroHugo Fernando Posada-Quintero
Hugo Fernando Posada-Quintero
Natasa ReljinNatasa Reljin
Natasa Reljin
CMCraig Mills
Craig Mills
IMIan Mills
Ian Mills
JFJohn P Florian
John P Florian
KCKi Chon
Ki Chon
The electrodermal activity (EDA) is a useful tool for assessing skin sympathetic nervous activity. Using spectral analysis of EDA data at rest, we have previously found that the spectral band which is the most sensitive to central sympathetic control is largely confined to 0.045 to 0.25 Hz. However, the frequency band associated with sympathetic control in EDA has not been studied for exercise conditions. Establishing the band limits more precisely is important to ensure the accuracy and sensitivity of the technique. As exercise intensity increases, it is intuitive that the frequencies associated with the autonomic dynamics should also increase accordingly. Hence, the aim of this study was to examine the appropriate frequency band associated with the sympathetic nervous system in the EDA signal during exercise. Eighteen healthy subjects underwent a sub-maximal exercise test, including a resting period, walking, and running, until achieving 85% of maximum heart rate. Both EDA and ECG data were measured simultaneously for all subjects. The ECG was used to monitor subjects’ instantaneous heart rate, which was used to set the experiment’s end point. We found that the upper bound of the frequency band (Fmax) containing the EDA spectral power significantly shifted to higher frequencies when subjects underwent prolonged low-intensity (Fmax ~ 0.28) and vigorous-intensity exercise (Fmax ~ 0.37 Hz) when compared to the resting condition. In summary, we have found shifting of the sympathetic dynamics to higher frequencies in the EDA signal when subjects undergo physical activity.

19 September 2019 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
Hugo Fernando Posada-QuinteroHugo Fernando Posada-Quintero
Hugo Fernando Posada-Quintero
Natasa ReljinNatasa Reljin
Natasa Reljin
JBJeffrey B. Bolkhovsky
Jeffrey B. Bolkhovsky
AOAlvaro D. Orjuela-Cañón
Alvaro D. Orjuela-Cañón
KCKi H. Chon
Ki H. Chon
We studied the correlation between oscillatory brain activity and performance in healthy subjects performing the error awareness task (EAT) every 2 h, for 24 h. In the EAT, subjects were shown on a screen the names of colors and were asked to press a key if the name of the color and the color it was shown in matched, and the screen was not a duplicate of the one before (“Go” trials). In the event of a duplicate screen (“Repeat No-Go” trial) or a color mismatch (“Stroop No-Go” trial), the subjects were asked to withhold from pressing the key. We assessed subjects’ (N = 10) response inhibition by measuring accuracy of the “Stroop No-Go” (SNGacc) and “Repeat No-Go” trials (RNGacc). We assessed their reactivity by measuring reaction time in the “Go” trials (GRT). Simultaneously, nine electroencephalographic (EEG) channels were recorded (Fp2, F7, F8, O1, Oz, Pz, O2, T7, and T8). The correlation between reactivity and response inhibition measures to brain activity was tested using quantitative measures of brain activity based on the relative power of gamma, beta, alpha, theta, and delta waves. In general, response inhibition and reactivity reached a steady level between 6 and 16 h of sleep deprivation, which was followed by sustained impairment after 18 h. Channels F7 and Fp2 had the highest correlation to the indices of performance. Measures of response inhibition (RNGacc and SNGacc) were correlated to the alpha and theta waves’ power for most of the channels, especially in the F7 channel (r = 0.82 and 0.84, respectively). The reactivity (GRT) exhibited the highest correlation to the power of gamma waves in channel Fp2 (0.76). We conclude that quantitative measures of EEG provide information that can help us to better understand changes in subjects’ performance and could be used as an indicator to prevent the adverse consequences of sleep deprivation.