Jesus Lazaro

Dr. Jesus Lazaro

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2023 in Physiological Measurement
Verified
Journal Article
Open access
Peter CharltonPeter Charlton
Peter Charlton
John AllenJohn Allen
John Allen
Raquel BailónRaquel Bailón
Raquel Bailón
SBStephanie Baker
Stephanie Baker
JBJoachim A Behar
Joachim A Behar
TZTingting Zhu
Tingting Zhu
Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.

21 September 2012 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
JLJesus Lazaro
Jesus Lazaro
EGEduardo Gil
Eduardo Gil
Raquel BailónRaquel Bailón
Raquel Bailón
AMAna Mincholé
Ana Mincholé
Pablo LagunaPablo Laguna
Pablo Laguna

13 April 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
AHAlberto Hernando
Alberto Hernando
JLJesus Lazaro
Jesus Lazaro
EGEduardo Gil
Eduardo Gil
AAAdriana Arza
Adriana Arza
JGJorge Mario Garzon
Jorge Mario Garzon
RBRaquel Bailon
Raquel Bailon
Respiratory rate and heart rate variability (HRV) are studied as stress markers in a database of young healthy volunteers subjected to acute emotional stress, induced by a modification of the Trier Social Stress Test. First, instantaneous frequency domain HRV parameters are computed using time-frequency analysis in the classical bands. Then, the respiratory rate is estimated and this information is included in HRV analysis in two ways: 1) redefining the high-frequency (HF) band to be centered at respiratory frequency; 2) excluding from the analysis those instants where respiratory frequency falls within the low-frequency (LF) band. Classical frequency domain HRV indices scarcely show statistical differences during stress. However, when including respiratory frequency information in HRV analysis, the normalized LF power as well as the LF/HF ratio significantly increase during stress (p-value <; 0.05 according to the Wilcoxon test), revealing higher sympathetic dominance. The LF power increases during stress, only being significantly different in a stress anticipation stage, while the HF power decreases during stress, only being significantly different during the stress task demanding attention. Our results support that joint analysis of respiration and HRV obtains a more reliable characterization of autonomic nervous response to stress. In addition, the respiratory rate is observed to be higher and less stable during stress than during relax (p-value <; 0.05 according to the Wilcoxon test) being the most discriminative index for stress stratification (AUC = 88.2%).

9 August 2018 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
AAAdriana Arza
Adriana Arza
JGJorge Mario Garzón-Rey
Jorge Mario Garzón-Rey
JLJesus Lazaro
Jesus Lazaro
EGEduardo Gil
Eduardo Gil
Raul López AntónRaul López Antón
Raul López Antón
JAJordi Aguiló
Jordi Aguiló
Social and medical problems associated with stress are increasing globally and seriously affect mental health and well-being. However, an effective stress-level monitoring method is still not available. This paper presents a quantitative method for monitoring acute stress levels in healthy young people using biomarkers from physiological signals that can be unobtrusively monitored. Two states were induced to 40 volunteers, a basal state generated with a relaxation task and an acute stress state generated by applying a standard stress test that includes five different tasks. Standard psychological questionnaires and biochemical markers were utilized as ground truth of stress levels. A multivariable approach to comprehensively measure the physiological stress response is proposed using stress biomarkers derived from skin temperature, heart rate, and pulse wave signals. Acute physiological stress levels (total-range 0–100 au) were continuously estimated every 1 min showing medians of 29.06 au in the relaxation tasks, while rising from 34.58 to 47.55 au in the stress tasks. Moreover, using the proposed method, five statistically different stress levels induced by the performed tasks were also measured. Results obtained show that, in these experimental conditions, stress can be monitored from unobtrusive biomarkers. Thus, a more general stress monitoring method could be derived based on this approach.

1 January 2014 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
JLJesus Lazaro
Jesus Lazaro
EGEduardo Gil
Eduardo Gil
JVJose Maria Vergara
Jose Maria Vergara
Pablo LagunaPablo Laguna
Pablo Laguna
A technique for ambulatory diagnosis of the obstructive sleep apnea syndrome (OSAS) in children based on pulse photoplethysmographic (PPG) signal is presented. Decreases in amplitude fluctuations of the PPG signal (DAP) events have been proposed as OSAS discriminator, since they are related to vasoconstriction associated to apnea. Heart rate variability (HRV) analysis during these DAP events has been proposed to discriminate between DAP events related or unrelated to an apneic event. The use of HRV requires electrocardiogram (ECG) as an additional recording, meaning a disadvantage that takes more relevance in sleep studies context where the number of sensors is tried to be minimized in order not to affect the physiological sleep. This study proposes the use of pulse rate variability (PRV) extracted from the PPG signal instead of HRV. Polysomnographic registers from 21 children (aged 4.47 ±2.04 years) were studied. The subject classification based on DAP events and PRV analysis obtained an accuracy of 86.67% which represents an improvement of 6.67% with respect to the HRV analysis. These results suggest that PRV can be used in apnea detectors based on DAP events, to discriminate apneic from nonapneic events avoiding the need for ECG recordings.

29 January 2021 in IEEE Transactions on Affective Computing
Verified
Journal Article
Closed access
Alberto GrecoAlberto Greco
Alberto Greco
GVGaetano Valenza
Gaetano Valenza
JLJesus Lazaro
Jesus Lazaro
JGJorge Mario Garzón-Rey
Jorge Mario Garzón-Rey
JAJordi Aguiló
Jordi Aguiló
Enzo Pasquale ScilingoEnzo Pasquale Scilingo
Enzo Pasquale Scilingo
Acute stress is a physiological condition that may induce several neural dysfunctions with a significant impact on life quality. Accordingly, it would be important to monitor stress in everyday life unobtrusively and inexpensively. In this paper, we presented a new methodological pipeline to recognize acute stress conditions using electrodermal activity (EDA) exclusively. Particularly, we combined a rigorous and robust model (cvxEDA) for EDA processing and decomposition, with an algorithm based on a support vector machine to classify the stress state at a single-subject level. Indeed, our method, based on a single sensor, is robust to noise, applies a rigorous phasic decomposition, and implements an unbiased multiclass classification. To this end, we analyzed the EDA of 65 volunteers subjected to different acute stress stimuli induced by a modified version of the Trier Social Stress Test. Our results show that stress is successfully detected with an average accuracy of 94.62%. Besides, we proposed a further 4-class pattern recognition system able to distinguish between non-stress condition and three different stressful stimuli achieving an average accuracy as high as 75.00%. These results, obtained under controlled conditions, are the first step towards applications in ecological scenarios.