To report our initial clinical experience with the novel surface imaging system Catalyst™ (C-RAD AB, Sweden) in connection with an Elekta Synergy linear accelerator for daily patient positioning in patients undergoing radiation therapy. We retrospectively analyzed the patient positioning of 154 fractions in 25 patients applied to thoracic, abdominal, and pelvic body regions. Patients were routinely positioned based on skin marks, shifted to the calculated isocenter position and treated after correction via cone beam CT which served as gold standard. Prior to CBCT an additional surface scan by the Catalyst™ system was performed and compared to a reference surface image cropped from the planning CT to obtain shift vectors for an optimal surface match. These shift vectors were subtracted from the vectors obtained by CBCT correction to assess the theoretical setup error that would have occurred if the patients had been positioned using solely the Catalyst™ system. The mean theoretical set up-error and its standard deviation were calculated for all measured fractions and the results were compared to patient positioning based on skin marks only. Integration of the surface scan into the clinical workflow did not result in a significant time delay. Regarding the entire group, the mean setup error by using skin marks only was 0.0 ± 2.1 mm in lateral, −0.4 ± 2.4 mm in longitudinal, and 1.1 ± 2.6 mm vertical direction. The mean theoretical setup error that would have occurred using solely the Catalyst™ was −0.1 ± 2.1 mm laterally, −1.8 ± 5.4 mm longitudinally, and 1.4 ± 3.2 mm vertically. No significant difference was found in any direction. For thoracic targets the mean setup error based on the Catalyst™ was 0.6 ± 2.6 mm laterally, −5.0 ± 7.9 mm longitudinally, and 0.5 ± 3.2 mm vertically. For abdominal targets, the mean setup error was 0.3 ± 2.2 mm laterally, 2.6 ± 1.8 mm longitudinally, and 2.1 ± 5.5 mm vertically. For pelvic targets, the setup error was −0.9 ± 1.5 mm laterally, −1.7 ± 2.8 mm longitudinally, and 1.6 ± 2.2 mm vertically. A significant difference between Catalyst™ and skin mark based positioning was only observed in longitudinal direction of pelvic targets. Optical surface scanning using Catalyst™ seems potentially useful for daily positioning at least to complement usual imaging modalities in most patients with acceptable accuracy, although a significant improvement compared to skin mark based positioning could not be derived from the evaluated data. However, this effect seemed to be rather caused by the unexpected high accuracy of skin mark based positioning than by inaccuracy using the Catalyst™. Further on, surface registration in longitudinal axis seemed less reliable especially in pelvic localization. Therefore further prospective evaluation based on strictly predefined protocols is needed to determine the optimal scanning approaches and parameters.
Knowing the technical characteristics of gated radiotherapy equipment is crucial for ensuring precise and accurate treatment when using techniques such as Deep-Inspiration Breath-Hold and gating under free breathing. With one of the first installations of the novel surface imaging system Catalyst™ (C-RAD AB, Sweden) in connection with an Elekta Synergy linear accelerator (Elekta AB, Sweden) via the Elekta Response Interface, characteristics like dose delivery accuracy and time delay were investigated prior to clinical implementation of gated treatments in our institution. In this study a moving phantom was used to simulate respiratory motion which was registered by the Catalyst™ system. The gating level was set manually. Within this gating window a trigger signal is automatically sent to the linac initiating treatment delivery. Dose measurements of gated linac treatment beams with different gating levels were recorded with a static 2D-Diode Array (MapCheck2, Sun Nuclear Co., USA) and compared to ungated reference measurements for different field sizes. In addition, the time delay of gated treatment beams was measured using radiographic film. The difference in dose delivery between gated and ungated treatment decreases with the size of the chosen gating level. For clinically relevant gating levels of about 30%, the differences in dose delivery accuracy remain below 1%. In comparison with other system configurations in literature, the beam-on time delay shows a large deviation of 851 ms ± 100 ms. When performing gated treatment, especially for free-breathing gating, factors as time delay and dose delivery have to be evaluated regularly in terms of a quality assurance process. Once these parameters are known they can be accounted and compensated for, e.g. by adjusting the pre-selected gating level or the internal target volume margins and by using prediction algorithms for breathing curves. The usage of prediction algorithms becomes inevitable with the high beam-on time delay which is reported here.
Purpose: To assess the feasibility and early results of online adaptive MR-guided radiotherapy (oMRgRT) of liver tumors. Methods: We retrospectively examined consecutive patients with primary or secondary liver lesions treated at our institution using a 0.35T hybrid MR-Linac (Viewray Inc., Mountain View, CA, USA). Online-adaptive treatment planning was used to account for interfractional anatomical changes, and real-time intrafractional motion management using online 2D cine MRI was performed using a respiratory gating approach. Treatment response and toxicity were assessed during follow-up. Results: Eleven patients and a total of 15 lesions were evaluated. Histologies included cholangiocarcinomas and metastases of neuroendocrine tumors, colorectal carcinomas, sarcomas and a gastrointestinal stroma tumor. The median BED10 of the PTV prescription doses was 84.4 Gy (range 59.5–112.5 Gy) applied in 3–5 fractions and the mean GTV BED10 was in median 147.9 Gy (range 71.7–200.5 Gy). Online plan adaptation was performed in 98% of fractions. The median overall treatment duration was 53 min. The treatment was feasible and successfully completed in all patients. After a median follow-up of five months, no local failure occurred and no ≥ grade two toxicity was observed. OMRgRT resulted in better PTV coverage and fewer OAR constraint violations. Conclusion: Early results of MR-linac based oMRgRT for the primary and secondary liver tumors are promising. The treatment was feasible in all cases and well tolerated with minimal toxicity. The technique should be compared to conventional SBRT in further studies to assess the advantages of the technique.
To report our experience with SBRT in primary and secondary liver tumors. We retrospectively analysed 55 patients (70 lesions) with a median follow-up of 10 months (range 1–57) treated from 2011 to 2016. All patients had not been eligible for other local treatment options. Median age was 64 years and 64% were male. 27 patients (36 lesions) suffered from hepatocellular carcinoma (HCC, Child A:78%, Child B:18%, Child C:4%), 28 patients (34 lesions) had oligometastatic liver disease (MD). Treatment planning was based on 4D-CT usually after placement of fiducials. Dose and fractionation varied depending on localization and size, most commonly 3 × 12.5 Gy (prescribed to the surrounding 65%-isodose) in 56% and 5x8Gy (80% isodose) in 20% of the treated lesions. Local recurrence was observed in 7 patients (13%) and 8 lesions (11%), resulting in estimated 1- and 2-year local control rates (LC) of 91 and 74%. Estimated 1- and 2-year rates of Freedom from hepatic failure (FFHF) were 42 and 28%. Number of lesions was predictive for LC and FFHF in the entire cohort. Estimated 1- and 2-year overall survival (OS) was 76 and 57%. OS was significantly affected by number of treated lesions and performance status. In the HCC subgroup, pretreatment liver function and gender were also predictive for OS. Maximum acute non-hepatic toxicity was grade 1 in 16% and grade 2 in 10% of the patients. Three HCC patients (11%) developed marked deterioration of liver function (grade 3/4). SBRT resulted in high local control and acceptable survival rates in patients with HCC or MD not amendable to other locally-ablative treatment options with limited toxicity. Care should be taken in HCC patients with Child B cirrhosis.
To analyse the outcome of elderly patients (≥70 years) with esophageal cancer treated with curative intent radio(chemo)therapy. Fifty five patients (median 75 years) receiving curative intent radio(chemo)therapy for esophageal cancer from 1999 to 2015 were retrospectively analyzed. Most patients showed locally advanced disease (T3/4:78%, N+:58%) with squamous cell histology (74%). Charlson comorbidity score was > 1 in 27%. 48 patients (87%) received definitive treatment while 7 patients were treated neoadjuvantly. RT was carried out as 3D-conformal treatment or IMRT. Concurrent chemotherapy was applied in 85%, mainly cisplatin/5-FU or mitomycin/5-FU. 18FDG-PET/CT staging was used in 65%. Median follow-up was 11 months (1–68) and 21 months in survivors. 1- and 2-year rates of LRC, DC, FFTF and OS were 60%/45, 81%/72, 55%/41 and 46%/26% for the entire cohort. In univariate analysis, addition of surgery was associated with improved LRC and FFTF, nodal involvement with improved DC and lower T stage, lower Charlson score and use of PET-CT with improved OS. In multivariate analysis, lower T stage and lower Charlson score remained significant for OS. Patients treated after 2008 showed a significantly improved FFTF (1-year FFTF 64% vs 35%) and OS (1-year OS 66% vs 24%). Maximum (chemo)radiation related grade3+ toxicity was observed in 80% including 7 deaths (13%). Grade5 toxicity was significantly associated with Charlson score (CS > 1:33% vs CS ≤ 1:5%) and treatment period (24% before vs 3% after 2008). The patients treated after 2008 included significantly more SCCs, less T4 stages, had a higher percentage of PET-CT staging and were treated with smaller field lengths. Trends were also observed for lower Charlson scores and increased use of IMRT. Curative intent (chemo)radiation of elderly patients with esophageal cancer may result in considerable toxicity and unfavorable outcome. However, a clear improvement over time was observed in our cohort, probably based on improved patient selection. In patients with less advanced stages and lower comorbidity similar results as in younger cohorts seem achievable with modern staging and treatment approaches. Age per se should not be a decisive factor, but careful attention should be paid regarding patient selection including a structured and tight follow-up strategy.
Background: In unresectable hepatocellular carcinoma several local ablative treatments are available. Among others, radiation based treatments such as stereotactic body radiotherapy (SBRT) and high-dose rate interstitial brachytherapy (HDR BT) have shown good local control rates. Methods: We conducted a dose comparison between actually performed HDR BT versus virtually planned SBRT to evaluate the respective clinically relevant radiation exposure to uninvolved liver tissue. Moreover, dose coverage and conformity indices were assessed. Results: Overall, 46 treatment sessions (71 lesions, 38 patients) were evaluated. HDR BT was applied in a single fraction with a dose prescription of 1 × 15 Gy. D98 was 17.9 ± 1.3 Gy, D50 was 41.8 ± 8.1 Gy. The SBRT was planned with a prescribed dose of 3 × 12.5 Gy (65%-Isodose), D98 was 50.7 ± 3.1 Gy, D2 was 57.0 ± 2.3 Gy, and D50 was 55.2 ± 2.3 Gy. Regarding liver exposure Vliver10GyBT was compared to Vliver15.9GySBRT, Vliver16.2GySBRT (EQD2 equivalent doses), and Vliver20GySBRT (clinically relevant dose), all results showed significant differences (p < .001). In a case by case analysis Vliver10GyBT was smaller than Vliver20GySBRT in 38/46 cases (83%). Dmean of the liver was significantly smaller in BT compared to SBRT (p < .001). GTV volume was correlated to the liver exposure and showed an advantage of HDR BT over SBRT in comparison of clinically relevant doses, and for EQD2 equivalent doses. The advantage was more pronounced for greater liver lesions The Conformity Index (CI) was significantly better for BT, while Healthy Tissue Conformity Index (HTCI) and Conformation Number (CN) showed an advantage for SBRT (p < .001). Conclusion: HDR BT can be advantageous in respect of sparing of normal liver tissue as compared to SBRT, while providing excellent target conformity.