Background: Hybrid magnetic resonance (MR)-Linac systems have recently been introduced into clinical practice. The systems allow online adaption of the treatment plan with the aim of compensating for interfractional anatomical changes. The aim of this study was to evaluate the dose volume histogram (DVH)-based dosimetric benefits of online adaptive MR-guided radiotherapy (oMRgRT) across different tumor entities and to investigate which subgroup of plans improved the most from adaption. Methods: Fifty patients treated with oMRgRT for five different tumor entities (liver, lung, multiple abdominal lymph nodes, pancreas, and prostate) were included in this retrospective analysis. Various target volume (gross tumor volume GTV, clinical target volume CTV, and planning target volume PTV) and organs at risk (OAR) related DVH parameters were compared between the dose distributions before and after plan adaption. Results: All subgroups clearly benefited from online plan adaption in terms of improved PTV coverage. For the liver, lung and abdominal lymph nodes cases, a consistent improvement in GTV coverage was found, while many fractions of the prostate subgroup showed acceptable CTV coverage even before plan adaption. The largest median improvements in GTV near-minimum dose (D98%) were found for the liver (6.3%, p < 0.001), lung (3.9%, p < 0.001), and abdominal lymph nodes (6.8%, p < 0.001) subgroups. Regarding OAR sparing, the largest median OAR dose reduction during plan adaption was found for the pancreas subgroup (-87.0%). However, in the pancreas subgroup an optimal GTV coverage was not always achieved because sparing of OARs was prioritized. Conclusion: With online plan adaptation, it was possible to achieve significant improvements in target volume coverage and OAR sparing for various tumor entities and account for interfractional anatomical changes.
Purpose: To assess the feasibility and early results of online adaptive MR-guided radiotherapy (oMRgRT) of liver tumors. Methods: We retrospectively examined consecutive patients with primary or secondary liver lesions treated at our institution using a 0.35T hybrid MR-Linac (Viewray Inc., Mountain View, CA, USA). Online-adaptive treatment planning was used to account for interfractional anatomical changes, and real-time intrafractional motion management using online 2D cine MRI was performed using a respiratory gating approach. Treatment response and toxicity were assessed during follow-up. Results: Eleven patients and a total of 15 lesions were evaluated. Histologies included cholangiocarcinomas and metastases of neuroendocrine tumors, colorectal carcinomas, sarcomas and a gastrointestinal stroma tumor. The median BED10 of the PTV prescription doses was 84.4 Gy (range 59.5–112.5 Gy) applied in 3–5 fractions and the mean GTV BED10 was in median 147.9 Gy (range 71.7–200.5 Gy). Online plan adaptation was performed in 98% of fractions. The median overall treatment duration was 53 min. The treatment was feasible and successfully completed in all patients. After a median follow-up of five months, no local failure occurred and no ≥ grade two toxicity was observed. OMRgRT resulted in better PTV coverage and fewer OAR constraint violations. Conclusion: Early results of MR-linac based oMRgRT for the primary and secondary liver tumors are promising. The treatment was feasible in all cases and well tolerated with minimal toxicity. The technique should be compared to conventional SBRT in further studies to assess the advantages of the technique.
Background and purpose: Chemoradiotherapy (CRT) followed by a brachytherapy (BT) boost is the standard of care for patients with locally advanced or recurrent gynecological cancer (LARGC). However, not every patient is suitable for BT. Therefore, we investigated the feasibility of an MR-guided SBRT boost (MRg-SBRT boost) following CRT of the pelvis. Material and methods: Ten patients with LARGC were analyzed retrospectively. The patients were not suitable for BT due to extensive infiltration of the pelvic wall (10%), other adjacent organs (30%), or both (50%), or ineligibility for anesthesia (10%). Online-adaptive treatment planning was performed to control for interfractional anatomical changes. Treatment parameters and toxicity were evaluated to assess the feasibility of MRg-SBRT boost. Results: MRg-SBRT boost was delivered to a median total dose of 21.0 Gy in 4 fractions. The median optimized PTV (PTVopt) size was 43.5ccm. The median cumulative dose of 73.6Gy10 was delivered to PTVopt. The cumulative median D2ccm of the rectum was 63.7 Gy; bladder 72.2 Gy; sigmoid 65.8 Gy; bowel 59.9 Gy (EQD23). The median overall treatment time/fraction was 77 min, including the adaptive workflow in 100% of fractions. The median duration of the entire treatment was 50 days. After a median follow-up of 9 months, we observed no CTCAE ≥ °II toxicities. Conclusion: These early results report the feasibility of an MRg-SBRT boost approach in patients with LARGC, who were not candidates for BT. When classical BT-OAR constraints are followed, the therapy was well tolerated. Long-term follow-up is needed to validate the results.
Local ablative treatments have emerged as a promising treatment strategy for patients with oligometastatic disease. Among others, interstitial brachytherapy (iBT) is an upcoming treatment option for unresectable liver metastases. We report the feasibility and oncologic outcome of iBT of oligometastatic liver metastases performed in patients with limited tumor burdens in a high-volume center. Patients undergoing iBT between August 2017and March 2019 were included. A retrospective analysis of patient outcomes and treatment complications was performed. Patients treated for metastatic colorectal carcinoma (CRC) were compared to other histologies. A total of 141 iBT procedures were performed in 106 patients (male:52; female:54) and 244 liver metastases. Overall, 51% (54/106) of patients had a diagnosis of metastatic CRC. The median follow-up was 9 months, and overall survival (OS) was 92.3% at 6 months and 76.3% at 12 months. Local-relapse-free survival (LRFS) was 88.4% at 6 months and 71.5% at 12 months, with a significant difference between patients with CRC (84.1% and 50.6%) versus other histologies (92.4% and 92.4%, p < 0.001). A sub-group analysis showed a significant advantage in patients with CRC receiving a minimal dose (D100) of 20 Gy to the planning target volume. Treatments of smaller total liver-tumor volumes (<18 ccm) resulted in better LRFS rates. iBT is a safe and effective treatment approach for oligometastatic liver disease. A higher treatment dose is needed for patients with CRC. Moreover, lower metastatic burdens may be favorable for LRFS. Prospective studies are needed to assess the role of iBT in the oligometastatic setting as an alternative to other local ablative treatment approaches in patients with liver metastases.
Background and purpose: To report on our clinical experience with a newly implemented workflow for radiotherapy (RT) emergency treatments, which allows for a fast treatment application outside the regular working-hours, and its clinical applicability. Methods: Treatment planning of 18 emergency RT patients was carried out using diagnostic computed tomography (CT) without a dedicated RT simulation CT. The cone-beam CT (CBCT) deviations of the first RT treatment were analyzed regarding setup accuracy. Furthermore, feasibility of the “fast-track” workflow was evaluated with respect to dose deviations caused by different Hounsfield unit (HU) to relative electron density (rED) calibrations and RT treatment couch surface shapes via 3D gamma index analysis of exemplary treatment plans. The dosimetric uncertainty introduced by different CT calibrations was quantified. Results: Mean patient setup vs. CBCT isocenter deviations were (0.49 ± 0.44) cm (x), (2.68 ± 1.63) cm (y) and (1.80 ± 1.06) cm (z) for lateral, longitudinal and vertical directions, respectively. Three out of four dose comparisons between the emergency RT plan calculated on the diagnostic CT and the same plan calculated on the treatment planning CT showed clinically acceptable gamma passing rates, when correcting for surface artifacts. The maximum difference of rED was 0.054, while most parts of the CT calibration curves coincided well. Conclusion: In an emergency RT setting, the use of diagnostic CT data for treatment planning might be time-saving and was shown to be suitable for many cases, considering reproducibility of patient setup, accuracy of initial patient setup and accuracy of dose-calculation.
16 March 2022 in Zeitschrift für Medizinische Physik
To date, no universally accepted technique for the evaluation of the overall dosimetric performance of hybrid integrated magnetic resonance imaging (MR) – linear accelerators (linacs) is available. We report on the suitability and reliability of a novel phantom with modular inserts for combined polymer gel (PG) and ionisation chamber (IC) measurements at a 0.35 T MR-linac. Three 3D-printed, modular head phantoms, based on real patient anatomy, were used for repeated (2 times) PG irradiations of cranial treatment plans on a 0.35 T MR-linac. The PG readout was performed on two 1.5 T diagnostic MR-scanners to reduce scanning time. The PG dose volumes were normalised to the IC dose (normalised dose N1) and to the median planning target volume dose (normalised dose N2). Linearity of the PG dose response was validated and dose profiles, centres of mass (COM) of the 95% isodoses and dose volume histograms (DVH) were compared between planned and measured dose distributions and a 3D gamma analysis was performed. Dose linearity of the PG was good (R2 > 0.99 for all linear fit functions). High agreement was found between planned and measured dose volumes in the dose profiles and DVHs. The largest dose deviation was found in the intermediate dose region (mean dose deviation 0.2 Gy; 5.6%). A mean COM offset of 1.2 mm indicated high spatial accuracy. Mean 3D gamma passing rates (2%, 2 mm) of 83.3% for N1 and 91.6% for N2 dose distributions were determined. When comparing repeated PG measurements to each other, a mean gamma passing rate of 95.7% was found. The new modular phantom was found practical for use at a 0.35 T MR-linac. In contrast to the high dose region, larger mean deviations were found in the mid dose range. The PG measurements showed high reproducibility. The MR-linac performed well in a non-adaptive setting in terms of spatial and dosimetric accuracy.