Carlos  Barrios

Dr. Carlos Barrios

Department of Photonics and Bioenginering, CEMDATIC, ETSI Telecomunicación, Universidad Politécnica de Madrid, Ciudad Universitaria s/n, 28040 Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
VAVilson R Almeida
Vilson R Almeida
QXQianfan Xu
Qianfan Xu
Carlos  BarriosCarlos Barrios
Carlos Barrios
MLMichal Lipson
Michal Lipson
We present a novel waveguide geometry for enhancing and confining light in a nanometer-wide low-index material. Light enhancement and confinement is caused by large discontinuity of the electric field at high-index-contrast interfaces. We show that by use of such a structure the field can be confined in a 50-nm-wide low-index region with a normalized intensity of 20 µm-2. This intensity is approximately 20 times higher than what can be achieved in SiO2 with conventional rectangular waveguides.

28 October 2004 in Nature
Verified
Journal Article
Closed access
VAVilson R Almeida
Vilson R Almeida
Carlos  BarriosCarlos Barrios
Carlos Barrios
RPRoberto R. Panepucci
Roberto R. Panepucci
MLMichal Lipson
Michal Lipson

17 October 2007 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Carlos  BarriosCarlos Barrios
Carlos Barrios
KGKristinn Gylfason
Kristinn Gylfason
BSBenito Sánchez
Benito Sánchez
AGAmadeu Griol
Amadeu Griol
HSH. Sohlström
H. Sohlström
RCR. Casquel
R. Casquel
We report an experimental demonstration of an integrated biochemical sensor based on a slot-waveguide microring resonator. The microresonator is fabricated on a Si3N4–SiO2 platform and operates at a wavelength of 1.3 μm. The transmission spectrum of the sensor is measured with different ambient refractive indices ranging from n=1.33 to 1.42. A linear shift of the resonant wavelength with increasing ambient refractive index of 212 nm/refractive index units (RIU) is observed. The sensor detects a minimal refractive index variation of 2×10−4 RIU.

12 November 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CCC. F. Carlborg
C. F. Carlborg
KGKristinn Gylfason
Kristinn Gylfason
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
FDFabian Dortu
Fabian Dortu
MBMaria-Jose Bañuls
Maria-Jose Bañuls
WWW. van der Wijngaart
W. van der Wijngaart
We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 × 10−6 refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm−2, to our knowledge the best reported values for integrated planar ring resonators.

28 March 2008 in Optics Letters
Verified
Journal Article
Open access
PDF file
Carlos  BarriosCarlos Barrios
Carlos Barrios
MBMaria-Jose Bañuls
Maria-Jose Bañuls
VGVictoria González-Pedro
Victoria González-Pedro
KGKristinn Gylfason
Kristinn Gylfason
BSBenito Sánchez
Benito Sánchez
RCR. Casquel
R. Casquel
We demonstrate label-free molecule detection by using an integrated biosensor based on a Si3N4∕SiO2 slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2nm∕(ng∕mm2) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16pg∕mm2 for anti-BSA and BSA, respectively, limited by wavelength resolution.

15 December 2004 in Optics Letters
Verified
Journal Article
Closed access
PDF file
VAVilson R Almeida
Vilson R Almeida
Carlos  BarriosCarlos Barrios
Carlos Barrios
RPRoberto R. Panepucci
Roberto R. Panepucci
MLMichal Lipson
Michal Lipson
MFMark A. Foster
Mark A. Foster
AGAlexander L. Gaeta
Alexander L. Gaeta
We present an experimental demonstration of fast all-optical switching on a silicon photonic integrated device by employing a strong light-confinement structure to enhance sensitivity to small changes in the refractive index. By use of a control light pulse with energy as low as 40 pJ, the optical transmission of the structure is modulated by more than 97% with a time response of 450 ps.