Maria-Jose Bañuls

Dr. Maria-Jose Bañuls

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CCC. F. Carlborg
C. F. Carlborg
KGKristinn Gylfason
Kristinn Gylfason
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
FDFabian Dortu
Fabian Dortu
MBMaria-Jose Bañuls
Maria-Jose Bañuls
WWW. van der Wijngaart
W. van der Wijngaart
We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 × 10−6 refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm−2, to our knowledge the best reported values for integrated planar ring resonators.

28 March 2008 in Optics Letters
Verified
Journal Article
Open access
PDF file
Carlos  BarriosCarlos Barrios
Carlos Barrios
MBMaria-Jose Bañuls
Maria-Jose Bañuls
VGVictoria González-Pedro
Victoria González-Pedro
KGKristinn Gylfason
Kristinn Gylfason
BSBenito Sánchez
Benito Sánchez
RCR. Casquel
R. Casquel
We demonstrate label-free molecule detection by using an integrated biosensor based on a Si3N4∕SiO2 slot-waveguide microring resonator. Bovine serum albumin (BSA) and anti-BSA molecular binding events on the sensor surface are monitored through the measurement of resonant wavelength shifts with varying biomolecule concentrations. The biosensor exhibited sensitivities of 1.8 and 3.2nm∕(ng∕mm2) for the detection of anti-BSA and BSA, respectively. The estimated detection limits are 28 and 16pg∕mm2 for anti-BSA and BSA, respectively, limited by wavelength resolution.


21 May 2018 in ACS Energy Letters
Verified
Journal Article
Closed access
VGVictoria González-Pedro
Victoria González-Pedro
SVSjoerd A. Veldhuis
Sjoerd A. Veldhuis
RBRaihana Begum
Raihana Begum
MBMaria-Jose Bañuls
Maria-Jose Bañuls
ABAnnalisa Bruno
Annalisa Bruno
Ángel MaquieiraÁngel Maquieira
Ángel Maquieira

5 November 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
VTVeronica Toccafondo
Veronica Toccafondo
MBMaria-Jose Bañuls
Maria-Jose Bañuls
JCJavier García Castelló
Javier García Castelló
AGAmadeu Griol
Amadeu Griol
Ángel MaquieiraÁngel Maquieira
Ángel Maquieira
We report experimental results of label-free anti-bovine serum albumin (anti-BSA) antibody detection using a SOI planar photonic crystal waveguide previously bio-functionalized with complementary BSA antigen probes. Sharp fringes appearing in the slow-light regime near the edge of the guided band are used to perform the sensing. We have modeled the presence of these band edge fringes and demonstrated the possibility of using them for sensing purposes by performing refractive index variations detection, achieving a sensitivity of 174.8 nm/RIU. Then, label-free anti-BSA biosensing experiments have been carried out, estimating a surface mass density detection limit below 2.1 pg/mm2 and a total mass detection limit below 0.2 fg.

28 October 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
VTVeronica Toccafondo
Veronica Toccafondo
JGJaime Garcia-Ruperez
Jaime Garcia-Ruperez
MBMaria-Jose Bañuls
Maria-Jose Bañuls
AGAmadeu Griol
Amadeu Griol
JCJ. G. Castelló
J. G. Castelló
Ángel MaquieiraÁngel Maquieira
Ángel Maquieira
We report an experimental demonstration of single-strand DNA (ssDNA) detection at room temperature using a photonic-crystal-waveguide-based optical sensor. The sensor surface was previously biofunctionalized with ssDNA probes to be used as specific target receptors. Our experiments showed that it is possible to detect these hybridization events using planar photonic-crystal structures, reaching an estimated detection limit as low as 19.8nM for the detection of the complementary DNA strand.